Development of an on-line automated sample clean-up method and liquid chromatography-tandem mass spectrometry analysis: application in an in vitro proteolytic assay

被引:10
|
作者
Drexler, D
Barlow, DJ
Falk, P
Cantone, J
Hernandez, D
Ranasinghe, A
Sanders, M
Warrack, B
McPhee, F
机构
[1] Bristol Myers Squibb Co, Pharmaceut Res Inst, Pharmaceut Candidate Optimizat Discovery Analyt, Wallingford, CT 06492 USA
[2] Bristol Myers Squibb Co, Pharmaceut Res Inst, Virol Discovery, Wallingford, CT 06492 USA
[3] Bristol Myers Squibb Co, Pharmaceut Res Inst, Pharmaceut Candidate Optimizat Discovery Analyt, Princeton, NJ 08543 USA
关键词
automation; on-line sample clean-up; ion exchange and peptide microtraps; liquid chromatography-tandem mass spectrometry (LC-MS; MS); proteolytic assay;
D O I
10.1007/s00216-005-0263-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence detection has been a method of choice in industry for screening assays, including identification of enzyme inhibitors, owing to its high-throughput capabilities, excellent reproducibility, and sensitivity. Occasionally, inhibitors are identified that challenge the fluorescence assay limit, necessitating the development of more sensitive detection methods to assess these compounds. For data mining purposes, however, original assay conditions may be required. A direct method transfer to highly sensitive and specific LC-MS-based methods has not always been possible due to the presence of MS-incompatible neutral detergents and non-volatile salts in the assay matrix. Utilizing an in vitro proteolytic screening assay for the serine protease hepatitis C virus (HCV) nonstructural (NS) 3 protease as a test case, we report the development of an automated sample clean-up procedure implemented on-line with liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis to complement fluorescence detection. Ion exchange and peptide microtraps were employed to remove MS-incompatible assay matrix components. Three protease inhibitors were used to validate the MS/MS method. Comparable potencies were achieved for these compounds when assessed by fluorescence and MS/MS detection. Furthermore, four-fold less enzyme could be utilized when employing the MS/MS method compared to fluorescence detection. The longer analysis time, however, resulted in reduced sample capacity. The potency of our designed HCV NS3 protease inhibitors are thus routinely evaluated using a continuous fluorescence-based assay. Only pertinent inhibitors approaching the fluorescence assay sensitivity limit are subsequently analyzed further by LC-MS/MS. This methodology allows us to maintain a database and to compare results independent of the detection method. Despite the relatively slow sample turnaround time of this LC-MS approach, the versatility of the automated on-line clean-up procedure and sample analysis can be applied to assays containing reagents which were historically considered to be MS incompatible.
引用
收藏
页码:1145 / 1154
页数:10
相关论文
共 50 条
  • [21] Simultaneous determination of thiamphenicol, florfenicol and florfenicol amine in swine muscle by liquid chromatography-tandem mass spectrometry with immunoaffinity chromatography clean-up
    Luo, Pengjie
    Chen, Xia
    Liang, Chunlai
    Kuang, Hua
    Lu, Liming
    Jiang, Zhigang
    Wang, Zhanhui
    Li, Cun
    Zhang, Suxia
    Shen, Jianzhong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (02): : 207 - 212
  • [22] Analysis of multiple pesticide residues in tobacco using pressurized liquid extraction, automated solid-phase extraction clean-up and gas chromatography-tandem mass spectrometry
    Haib, J
    Hofer, I
    Renaud, JM
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1020 (02) : 173 - 187
  • [23] On-line immunoaffinity column-liquid chromatography-tandem mass spectrometry method for trace analysis of diuron in wastewater treatment plant effluent sample
    Zhang, Xiuli
    Martens, Dieter
    Kraemer, Petra M.
    Kettrup, Antonius A.
    Liang, Xinmiao
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1133 (1-2) : 112 - 118
  • [24] Monolithic silica columns of various format in automated sample clean-up/multidimensional liquid chromatography/mass spectrometry for peptidomics
    Machtejevas, Egidijus
    Andrecht, Sven
    Lubda, Dieter
    Unger, Klaus K.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1144 (01) : 97 - 101
  • [25] Development of the first liquid chromatography-tandem mass spectrometry assay for antiretrovirals in meconium
    Himes, S.
    Scheidweiler, K.
    Tassiopoulos, K.
    Kacanek, D.
    Hazra, R.
    Rich, K.
    Huestis, M.
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2012, 15 : 70 - 70
  • [26] Special Considerations for Liquid Chromatography-Tandem Mass Spectrometry Method Development
    Rappold, Brian A.
    CLINICS IN LABORATORY MEDICINE, 2018, 38 (03) : 539 - +
  • [27] Simultaneous Determination of 8 Mycotoxins in Aquatic Products by Liquid Chromatography-Tandem Mass Spectrometry Coupled with Immunoaffinity Column Clean-up
    Li Y.
    Zhang Q.
    Yang H.
    Zhu X.
    Shen M.
    Chen H.
    Science and Technology of Food Industry, 2023, 44 (07) : 294 - 300
  • [28] Application of liquid chromatography-tandem mass spectrometry to the analysis of benzodiazepines in blood
    Rivera, HM
    Walker, GS
    Sims, DN
    Stockham, PC
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2003, 9 (06) : 599 - 607
  • [29] Analysis of polycyclic aromatic hydrocarbons in cigarette samples using gel permeation chromatography clean-up by gas chromatography-tandem mass spectrometry
    Lian, Wenliu
    Ren, Fenglian
    Tang, Liyun
    Dong, Daozhu
    MICROCHEMICAL JOURNAL, 2016, 129 : 194 - 199
  • [30] Evaluation of automated clean-up for large scope pesticide multiresidue analysis by liquid chromatography coupled to mass spectrometry
    Manzano Sanchez, Lorena
    Jesus, Florencia
    Ferrer, Carmen
    Mar Gomez-Ramos, M.
    Fernandez-Alba, Amadeo
    JOURNAL OF CHROMATOGRAPHY A, 2023, 1694