Development of an on-line automated sample clean-up method and liquid chromatography-tandem mass spectrometry analysis: application in an in vitro proteolytic assay

被引:10
|
作者
Drexler, D
Barlow, DJ
Falk, P
Cantone, J
Hernandez, D
Ranasinghe, A
Sanders, M
Warrack, B
McPhee, F
机构
[1] Bristol Myers Squibb Co, Pharmaceut Res Inst, Pharmaceut Candidate Optimizat Discovery Analyt, Wallingford, CT 06492 USA
[2] Bristol Myers Squibb Co, Pharmaceut Res Inst, Virol Discovery, Wallingford, CT 06492 USA
[3] Bristol Myers Squibb Co, Pharmaceut Res Inst, Pharmaceut Candidate Optimizat Discovery Analyt, Princeton, NJ 08543 USA
关键词
automation; on-line sample clean-up; ion exchange and peptide microtraps; liquid chromatography-tandem mass spectrometry (LC-MS; MS); proteolytic assay;
D O I
10.1007/s00216-005-0263-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fluorescence detection has been a method of choice in industry for screening assays, including identification of enzyme inhibitors, owing to its high-throughput capabilities, excellent reproducibility, and sensitivity. Occasionally, inhibitors are identified that challenge the fluorescence assay limit, necessitating the development of more sensitive detection methods to assess these compounds. For data mining purposes, however, original assay conditions may be required. A direct method transfer to highly sensitive and specific LC-MS-based methods has not always been possible due to the presence of MS-incompatible neutral detergents and non-volatile salts in the assay matrix. Utilizing an in vitro proteolytic screening assay for the serine protease hepatitis C virus (HCV) nonstructural (NS) 3 protease as a test case, we report the development of an automated sample clean-up procedure implemented on-line with liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis to complement fluorescence detection. Ion exchange and peptide microtraps were employed to remove MS-incompatible assay matrix components. Three protease inhibitors were used to validate the MS/MS method. Comparable potencies were achieved for these compounds when assessed by fluorescence and MS/MS detection. Furthermore, four-fold less enzyme could be utilized when employing the MS/MS method compared to fluorescence detection. The longer analysis time, however, resulted in reduced sample capacity. The potency of our designed HCV NS3 protease inhibitors are thus routinely evaluated using a continuous fluorescence-based assay. Only pertinent inhibitors approaching the fluorescence assay sensitivity limit are subsequently analyzed further by LC-MS/MS. This methodology allows us to maintain a database and to compare results independent of the detection method. Despite the relatively slow sample turnaround time of this LC-MS approach, the versatility of the automated on-line clean-up procedure and sample analysis can be applied to assays containing reagents which were historically considered to be MS incompatible.
引用
收藏
页码:1145 / 1154
页数:10
相关论文
共 50 条
  • [1] Development of an on-line automated sample clean-up method and liquid chromatography–tandem mass spectrometry analysis: application in an in vitro proteolytic assay
    Dieter Drexler
    Deborah J. Barlow
    Paul Falk
    Joseph Cantone
    Dennis Hernandez
    Asoka Ranasinghe
    Mark Sanders
    Bethanne Warrack
    Fiona McPhee
    Analytical and Bioanalytical Chemistry, 2006, 384 : 1145 - 1154
  • [2] Determination of eight sulfonamides in bovine kidney by liquid chromatography/tandem mass spectrometry with on-line extraction and sample clean-up
    Van Eeckhout, N
    Perez, JC
    Van Peteghem, C
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (24) : 2331 - 2338
  • [3] Determination of eight sulfonamides in bovine kidney by liquid chromatography/tandem mass spectrometry with on-line extraction and sample clean-up
    Van Eeckhout, Nico
    Perez, José Castro
    Van Peteghem, Carlos
    2000, John Wiley and Sons Ltd (14)
  • [4] Determination of tetracyclines in bovine kidney by liquid chromatography/tandem mass spectrometry with on-line extraction and clean-up
    Van Eeckhout, N
    Perez, JC
    Claereboudt, J
    Vandeputte, R
    Van Peteghem, C
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (04) : 280 - 285
  • [5] Use of gel permeation chromatography for clean-up in the analysis of coccidiostats in eggs by liquid chromatography-tandem mass spectrometry
    Chico, J.
    Rubies, A.
    Centrich, F.
    Companyo, R.
    Prat, M. D.
    Granados, M.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (14) : 4777 - 4786
  • [6] Simultaneous pressurized liquid extraction and clean-up for the analysis of polybrominated biphenyls by gas chromatography-tandem mass spectrometry
    Malavia, J.
    Santos, F. J.
    Galceran, M. T.
    TALANTA, 2011, 84 (04) : 1155 - 1162
  • [7] A fully automated on-line preconcentration and liquid chromatography-tandem mass spectrometry method for the analysis of anti-infectives in wastewaters
    Segura, Pedro A.
    Gagnon, Christian
    Sauve, Sebastien
    ANALYTICA CHIMICA ACTA, 2007, 604 (02) : 147 - 157
  • [8] Determination of Ochratoxin A in spices by liquid chromatography-tandem mass spectrometry after immunoaffinity column clean-up
    Barricelli, M.
    Schmidt, K.
    Boerner, B.
    DEUTSCHE LEBENSMITTEL-RUNDSCHAU, 2007, 103 (01) : 1 - 3
  • [9] Determination of 26 Mycotoxins in Feedstuffs by Multifunctional Clean-up Column and Liquid Chromatography-Tandem Mass Spectrometry
    Wang Rui-Guo
    Su Xiao-Ou
    Cheng Fang-Fang
    Wang Pei-Long
    Fan Xia
    Zhang Wei
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (02) : 264 - 269
  • [10] Analysis of chloramphenicol in honey by on-line pretreatment liquid chromatography-tandem mass spectrometry
    Kawano, Shin-ichi
    Hao, Hong-Yuan
    Hashi, Yuki
    Lin, Jin-Ming
    CHINESE CHEMICAL LETTERS, 2015, 26 (01) : 36 - 38