Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross-sectional study

被引:26
|
作者
An, Youngju [1 ]
Kang, Eun-Kyoung [2 ]
Kim, Hyojin [3 ,4 ]
Kang, Min-Ji [5 ]
Byun, Yong-Soo [5 ]
Joo, Choun-Ki [1 ,5 ]
机构
[1] Catholic Univ Korea, Coll Med, Catholic Inst Visual Sci, Seoul, South Korea
[2] Inha Univ, Dept Phys, Thin Film Opt Lab, Incheon, South Korea
[3] Baekseok Univ, Div Hlth Sci, Dept Visual Opt, Cheonan, South Korea
[4] Baekseok Univ, Grad Sch Hlth & Welf, Cheonan, South Korea
[5] Catholic Univ Korea, Seoul St Marys Hosp, Dept Ophthalmol & Visual Sci, Coll Med, 505 Banpo Dong, Seoul 137040, South Korea
基金
新加坡国家研究基金会;
关键词
Intraocular lens power calculation; Cataract; Swept-source optical coherence tomography; Partial coherence interferometry; ULTRASOUND BIOMETRY; CATARACT; INTERFEROMETRY; REPRODUCIBILITY; PERFORMANCE; IMPACT;
D O I
10.1186/s12886-019-1036-y
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo evaluate the accuracy of biometric measurements by a swept-source optical coherence tomography (SS-OCT) based biometry for intraocular lens (IOL) power calculation.MethodsThis retrospective observational study enrolled 431 patients undergoing cataract surgery. The charts were reviewed to investigate the failure rate of axial length (AL) measurement of the SS-OCT biometer, partial coherence interferometry (PCI), and A-scan ultrasonography (US) according to cataract type and severity. AL and keratometry in 164 eyes with the same IOL inserted were measured using the SS-OCT biometer, PCI, and A-scan US. The SRK/T formula was used to calculate IOL power. The mean absolute error (MAE) and percentage of eyes with a prediction error (PE) of 0.50 D were compared.ResultsThe AL measurement failure rate was 0.00% for A-scan US, 2.32% for the SS-OCT biometer, and 15.31% for PCI. The number of eyes measured using three devices (SS-OCT biometer, PCI, and A-scan US) was 128 (Group A) and the number of eyes measured using two devices (SS-OCT biometer and A-scan US) was 36 (Group B). The score of posterior subcapsular opacity was significantly different between two groups (p<.001). The SS-OCT biometer and PCI showed significantly lower MAE compared to A-scan US in Group A (p=0.027). Using SS-OCT biometer, MAE showed no significant difference between Group A (0.360.27) and Group B (0.36 +/- 0.31) (p=0.785). Whereas, MAE of A-scan US was significantly higher than Group A (0.47 +/- 0.39) in Group B (0.64 +/- 0.36) (p=0.023).Conclusions Using biometry with advanced OCT is useful in clinical practice as it is more effective in obtaining biometric measurements in the eyes with PSC and provides accurate measurements for IOL power calculation regardless of cataract type and severity.Trial registration Retrospectively registered. Registration number: KC16RISI1020. Registered 03 January 2018.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Prediction accuracy of standard and total keratometry by swept-source optical biometer for multifocal intraocular lens power calculation
    Lee, Hun
    Chung, Jae Lim
    Kim, Young Jun
    Kim, Jae Yong
    Tchah, Hungwon
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [22] Total keratometry for toric intraocular lens calculation: comparison from two swept-source optical coherence tomography biometers
    Chai, Feiyan
    Ma, Jack X.
    Wang, Xiaogang
    Liu, Jiewei
    Jiang, Lin
    Wu, Wanmin
    Li, Junhong
    FRONTIERS IN MEDICINE, 2024, 10
  • [23] Accuracy of a New Swept-Source Optical Coherence Tomography Biometer for IOL Power Calculation and Comparison to IOL Master
    Savini, Giacomo
    Hoffer, Kenneth J.
    Shammas, H. John
    Aramberri, Jaime
    Huang, Jinhai
    Barboni, Piero
    JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (10) : 690 - 695
  • [24] Evaluation of crystalline lens and Chock for intraocular lens tilt using a swept-source optical coherence tomography biometer
    Wang, Li
    de Souza, Rodrigo Guimaraes
    Weikert, Mitchell P.
    Koch, Douglas D.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (01): : 35 - 40
  • [25] Differentiation of anterior chamber pigment and inflammatory cells using swept-source optical coherence tomography: a cross-sectional study
    Bellchambers, Alice
    Shu, Rongling
    Chu, Colin J.
    Petrushkin, Harry
    Solebo, Ameenat Lola
    EYE, 2025,
  • [26] Accuracy of intraocular lens calculation formulas based on swept-source OCT biometer in cataract patients with phakic intraocular lens
    Zeng, Zongsheng
    Zhu, Meiyi
    Zhang, Guangbin
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [27] Clinically Significant Intraocular Lens Decentration and Tilt in Highly Myopic Eyes: A Swept-Source Optical Coherence Tomography Study
    Wang, Lanhua
    Jin, Guangming
    Zhang, Jiaqing
    Chen, Xiaoyun
    Tan, Xuhua
    Wang, Wei
    Ruan, Xiaoting
    Gu, Xiaoxun
    He, Mingguang
    Liu, Zhenzhen
    Luo, Lixia
    Liu, Yizhi
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2022, 235 : 46 - 55
  • [28] Noninvasive cross-sectional imaging of incomplete crown fractures (cracks) using swept-source optical coherence tomography
    Nakajima, Y.
    Shimada, Y.
    Miyashin, M.
    Takagi, Y.
    Tagami, J.
    Sumi, Y.
    INTERNATIONAL ENDODONTIC JOURNAL, 2012, 45 (10) : 933 - 941
  • [29] Detecting macular disease with a biometry device using swept-source optical coherence tomography
    Tan, Colin S.
    Cheong, Kai Xiong
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (10): : 1544 - 1545
  • [30] Swept-source optical coherence tomography changes and visual acuity among Palestinian retinitis Pigmentosa patients: a cross-sectional study
    Shalabi, Orjowan
    Nazzal, Zaher
    Natsheh, Muath
    Iriqat, Salam
    Michaelides, Michel
    Ghanem, Muyassar
    Aslanian, Alice
    Alswaiti, Yahya
    AlTalbishi, Alaa
    BMC OPHTHALMOLOGY, 2021, 21 (01)