WHY NEUTRAL-GROUNDING RESISTORS NEED CONTINUOUS MONITORING

被引:0
|
作者
Selkirk, Donald [1 ]
Savostianik, Mervin [1 ]
Crawford, Kenneth [2 ]
机构
[1] Startco Engn Ltd, 406 Jessop Ave, Saskatoon, SK S7N 2S5, Canada
[2] DuPont Co Inc, Washington, DC 26181 USA
关键词
Resistance grounding; ground-fault protection; neutral-grounding-resistor monitor; neutral-grounding-resistor failure;
D O I
暂无
中图分类号
TE [石油、天然气工业];
学科分类号
0820 ;
摘要
A resistance-grounded power system has a critical element that is often ignored-the neutral-g rounding resistor. A resistance-grounded power system should have it's neutral-grounding resistor continuously monitored. During a single-phase-to-ground fault, current flows from the transformer or generator winding through the faulted-phase conductor to the fault and to ground, returning to the source winding through the ground-return path and the neutral-grounding resistor. When a neutral-grounding resistor fails, the failure mode is usually open circuit leaving the ground-return path open. Current-sensing ground-fault protection, which is the type most commonly employed in a resistance-grounded system, will not operate with an open resistor, and the advantages of resistance grounding are unknowingly lost. Inadvertent operation with an ungrounded system and inoperative ground-fault protection can be avoided by using a continuous neutral-grounding-resistor monitor. This paper reviews the benefits of resistance grounding, compares continuous resistor monitoring with planned-maintenance testing and inspection, and defines the characteristics required of a neutral-grounding-resistor-monitor. Three case studies are presented that show the need for continuous monitoring of the neutral-grounding resistor.
引用
收藏
页码:155 / +
页数:2
相关论文
共 50 条
  • [31] WHICH STANDARDS DO WE NEED FOR CONTINUOUS GLUCOSE MONITORING (CGM)?
    Freckmann, G.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A8 - A8
  • [32] Monitoring aquatic systems: The need and potential for continuous chemical sensing.
    Dzombak, DA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U638 - U638
  • [33] Universal prevention of substance use in school settings: the need for continuous monitoring
    Puertolas-Gracia, Beatriz
    Juarez, Olga
    Ariza, Carles
    Villalbi, Joan R.
    GACETA SANITARIA, 2022, 36 (05) : 493 - 495
  • [34] The dark side of the CPAP helmet: Why we need more monitoring systems
    Bambi, Stefano
    Manici, Matteo
    El Aoufy, Khadija
    Longobucco, Yari
    Lucchini, Alberto
    INTENSIVE AND CRITICAL CARE NURSING, 2023, 77
  • [35] Why we need long- term monitoring to understand ecosystem change
    Hollister, Robert D.
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2024, 121 (27) : 1 - 2
  • [36] Why on earth can people need continuous recycle membrane reactors for starch hydrolysis?
    Paolucci-Jeanjean, D
    Belleville, MP
    Rios, GM
    Zakhia, N
    STARCH-STARKE, 1999, 51 (01): : 25 - 32
  • [37] Do we need continuous ECG monitoring in patients transferred for primary angioplasty?
    Aude, YW
    Mehta, JL
    EUROPEAN HEART JOURNAL, 2006, 27 (03) : 249 - 250
  • [39] Continuous glucose monitoring in the neonatal intensive care unit: need for practical guidelines
    Beardsall, Kathryn
    Thomson, Lynn
    Iglesias-Platas, Isabel
    van Weissenbruch, Mirjam M.
    Bond, Simon
    Dunger, David
    LANCET CHILD & ADOLESCENT HEALTH, 2021, 5 (05): : E16 - E16
  • [40] Continuous glucose monitoring in patients with type 2 diabetes: Why? When? Whom?
    Monnier, L.
    Colette, C.
    Boegner, C.
    Pham, T. C.
    Lapinski, H.
    Boniface, H.
    DIABETES & METABOLISM, 2007, 33 (04) : 247 - 252