WHY NEUTRAL-GROUNDING RESISTORS NEED CONTINUOUS MONITORING

被引:0
|
作者
Selkirk, Donald [1 ]
Savostianik, Mervin [1 ]
Crawford, Kenneth [2 ]
机构
[1] Startco Engn Ltd, 406 Jessop Ave, Saskatoon, SK S7N 2S5, Canada
[2] DuPont Co Inc, Washington, DC 26181 USA
来源
INDUSTRY APPLICATIONS SOCIETY 55TH ANNUAL PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE | 2008年
关键词
Resistance grounding; ground-fault protection; neutral-grounding-resistor monitor; neutral-grounding-resistor failure;
D O I
暂无
中图分类号
TE [石油、天然气工业];
学科分类号
0820 ;
摘要
A resistance-grounded power system has a critical element that is often ignored-the neutral-g rounding resistor. A resistance-grounded power system should have it's neutral-grounding resistor continuously monitored. During a single-phase-to-ground fault, current flows from the transformer or generator winding through the faulted-phase conductor to the fault and to ground, returning to the source winding through the ground-return path and the neutral-grounding resistor. When a neutral-grounding resistor fails, the failure mode is usually open circuit leaving the ground-return path open. Current-sensing ground-fault protection, which is the type most commonly employed in a resistance-grounded system, will not operate with an open resistor, and the advantages of resistance grounding are unknowingly lost. Inadvertent operation with an ungrounded system and inoperative ground-fault protection can be avoided by using a continuous neutral-grounding-resistor monitor. This paper reviews the benefits of resistance grounding, compares continuous resistor monitoring with planned-maintenance testing and inspection, and defines the characteristics required of a neutral-grounding-resistor-monitor. Three case studies are presented that show the need for continuous monitoring of the neutral-grounding resistor.
引用
收藏
页码:155 / +
页数:2
相关论文
共 50 条
  • [21] Continuous Glucose Monitoring (CGM) Accuracy, Real-Time vs. Retrofitted: Why We Need Both
    Breton, Marc D.
    Kovatchev, Boris P.
    DIABETES, 2012, 61 : A215 - A215
  • [22] Do We Really Need Continuous Glucose Monitoring?
    Peters, Anne
    DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 : S128 - S130
  • [23] NEED FOR CONTINUOUS BACTERIOPHAGE MONITORING IN CHEDDAR CHEESE FACTORIES
    WARIS, SI
    HONG, GL
    RICHARDSON, GH
    JONAS, LH
    JOURNAL OF DAIRY SCIENCE, 1977, 60 : 38 - 38
  • [24] Why we need a vendor neutral specification for delineating prostate cancer with mpMRI
    Daniel J. A. Margolis
    Antonio C. Westphalen
    Masoom A. Haider
    Abdominal Radiology, 2016, 41 : 801 - 802
  • [25] Why we need a vendor neutral specification for delineating prostate cancer with mpMRI
    Margolis, Daniel J. A.
    Westphalen, Antonio C.
    Haider, Masoom A.
    ABDOMINAL RADIOLOGY, 2016, 41 (05) : 801 - 802
  • [26] Why We Need Continuous Pharmaceutical Manufacturing and How to Make It Happen
    Badman, Clive
    Cooney, Charles L.
    Florence, Alastair
    Konstantinov, Konstantin
    Krumme, Markus
    Mascia, Salvatore
    Nasr, Moheb
    Trout, Bernhardt L.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 108 (11) : 3521 - 3523
  • [27] Oxidative stress in obstructive sleep apnea: Need for continuous monitoring
    Suzuki, Yuichiro J.
    Park, Ah-Mee
    Jain, Vivek
    Day, Regina M.
    FREE RADICAL BIOLOGY AND MEDICINE, 2007, 42 (06) : 895 - 895
  • [28] THE NEED FOR CONTINUOUS CEREBRAL-ACTIVITY MONITORING IN TREATMENT OF SEIZURES
    POURCYROUS, M
    STIDHAM, G
    BUSIJA, D
    BADA, H
    KORONES, S
    PEDIATRIC RESEARCH, 1989, 25 (04) : A228 - A228
  • [29] Do pregnant women with gestational diabetes need continuous glucose monitoring?
    Shen, Song-Ying
    Zurauskiene, Justina
    Wei, Dong-Mei
    Chen, Nian-Nian
    Lu, Jin-Hua
    Liu, Hui-Hui
    Cazier, Jean-Baptiste
    Xia, Hui-Min
    Qiu, Xiu
    LANCET, 2019, 394 : 77 - 77
  • [30] Data Sharing of Continuous Glucose Monitoring Data: The Need for a New Paradigm?
    Cichosz, Simon