WHY NEUTRAL-GROUNDING RESISTORS NEED CONTINUOUS MONITORING

被引:0
|
作者
Selkirk, Donald [1 ]
Savostianik, Mervin [1 ]
Crawford, Kenneth [2 ]
机构
[1] Startco Engn Ltd, 406 Jessop Ave, Saskatoon, SK S7N 2S5, Canada
[2] DuPont Co Inc, Washington, DC 26181 USA
关键词
Resistance grounding; ground-fault protection; neutral-grounding-resistor monitor; neutral-grounding-resistor failure;
D O I
暂无
中图分类号
TE [石油、天然气工业];
学科分类号
0820 ;
摘要
A resistance-grounded power system has a critical element that is often ignored-the neutral-g rounding resistor. A resistance-grounded power system should have it's neutral-grounding resistor continuously monitored. During a single-phase-to-ground fault, current flows from the transformer or generator winding through the faulted-phase conductor to the fault and to ground, returning to the source winding through the ground-return path and the neutral-grounding resistor. When a neutral-grounding resistor fails, the failure mode is usually open circuit leaving the ground-return path open. Current-sensing ground-fault protection, which is the type most commonly employed in a resistance-grounded system, will not operate with an open resistor, and the advantages of resistance grounding are unknowingly lost. Inadvertent operation with an ungrounded system and inoperative ground-fault protection can be avoided by using a continuous neutral-grounding-resistor monitor. This paper reviews the benefits of resistance grounding, compares continuous resistor monitoring with planned-maintenance testing and inspection, and defines the characteristics required of a neutral-grounding-resistor-monitor. Three case studies are presented that show the need for continuous monitoring of the neutral-grounding resistor.
引用
收藏
页码:155 / +
页数:2
相关论文
共 50 条
  • [1] Monitoring neutral-grounding resistors
    Paulson, GE
    CONFERENCE RECORD OF 1999 ANNUAL PULP AND PAPER INDUSTRY TECHNICAL CONFERENCE, 1999, : 238 - 241
  • [2] A Continuous Monitoring for Neutral Grounding Resistors and Reactors With Hardware Validation
    Jafari, Rahim
    Kanabar, Mital
    Sidhu, Tarlochan S.
    Voloh, Ilia
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (04) : 1341 - 1349
  • [3] New Methods for Monitoring Neutral Grounding Resistors
    Jafari, Rahim
    Kanabar, Mital
    Voloh, Ilia
    Sidhu, Tarlochan S.
    2018 71ST ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS (CPRE), 2018,
  • [4] Neutral grounding resistors for electrical distribution systems
    不详
    DIESEL PROGRESS NORTH AMERICAN EDITION, 1997, 63 (09): : 22 - 22
  • [5] DEVELOPMENT OF A NOVEL METHOD FOR CONTINUOUS NEUTRAL GROUNDING RESISTOR MONITORING
    Jensen, Kristophor
    Pollock, Mark
    2023 IEEE IAS PETROLEUM AND CHEMICAL INDUSTRY TECHNICAL CONFERENCE, PCIC, 2023, : 253 - 262
  • [6] Impact Evaluation of the Neutral-Grounding Resistance on Short-Duration RMS Voltage Variations
    da Costa, Lucas Araujo
    Mohammadi, Younes
    Leborgne, Roberto Chouhy
    Gazzana, Daniel da Silva
    2020 19TH INTERNATIONAL CONFERENCE ON HARMONICS AND QUALITY OF POWER (ICHQP), 2020,
  • [7] Grounding the neutral of electrical systems through low resistance grounding resistors: An application case.
    Mitolo, M
    Conference Record of the 2005 IEEE Industry Applications Conference, Vols 1-4, 2005, : 1497 - 1502
  • [8] Grounding the neutral of electrical systems through low-resistance grounding resistors: An application case
    Mitolo, Massimo
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2008, 44 (05) : 1311 - 1316
  • [9] Modelling and analysis of delta-connected distribution transformers with symmetrical neutral-grounding structure for microgrid networks
    Liao, Rih-Neng
    Yang, Nien-Che
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 97 : 40 - 50
  • [10] Application and monitoring of SF6 gas-insulated NGR (neutral grounding resistor) using ceramic resistors
    Shirakawa, S
    Terakado, S
    Miyake, J
    Tanaka, S
    Takasugi, K
    Yamashita, T
    ELECTRICAL ENGINEERING IN JAPAN, 2001, 137 (04) : 32 - 37