Experimental validation of finite element model for proximal composite femur using optical measurements

被引:66
|
作者
Grassi, Lorenzo [1 ,2 ]
Vaananen, Sami P. [3 ]
Yavari, Saber Amin [4 ]
Weinans, Harrie [4 ,5 ]
Jurvelin, Jukka S. [3 ]
Zadpoor, Amir A. [4 ]
Isaksson, Hanna [1 ,2 ]
机构
[1] Lund Univ, Div Solid Mech, Lund, Sweden
[2] Lund Univ, Dept Orthoped, Lund, Sweden
[3] Univ Eastern Finland, Dept Appl Phys, Kuopio, Finland
[4] Delft Univ Technol, Fac Mech Maritime & Mat Engn, Delft, Netherlands
[5] Erasmus MC, Dept Orthoped, Rotterdam, Netherlands
基金
芬兰科学院; 瑞典研究理事会;
关键词
Digital image correlation; Composite femur; Finite element; Bone fracture; DIGITAL-IMAGE-CORRELATION; STRAIN DISTRIBUTION; HIP-FRACTURES; BONE; OSTEOPOROSIS; ACCURACY; STRENGTH; MECHANICS; DENSITY; WOMEN;
D O I
10.1016/j.jmbbm.2013.02.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patient-specific finite element models have been used to predict femur strength and fracture risk in individuals. Validation of the adopted finite element modelling procedure against mechanical testing data is a crucial step when aiming for clinical applications. The majority of the works available in literature used data from strain gages to validate the model, thus having up to 15 experimental measurements. Optical techniques, such as digital image correlation, can help to improve the models by providing a continuous field of deformation data over a femoral surface. The main objective of this study was to validate finite element models of six composite femora against strain data from digital image correlation, obtained during fracture tests performed in quasi-axial loading configuration. The finite element models were obtained from CT scans, by means of a semi-automatic segmentation. The principal strains both during the elastic phase and close to the fracture were compared, and showed a correlation coefficient close to 0.9. In the linear region, the slope and intercept were close to zero and unity, while for the case when fracture load was simulated, the slope decreased somewhat. The accuracy of the obtained results is comparable with the state-of-the-art literature, with the significant improvement of having around 50,000 data points for each femur. This large number of measurements allows a more comprehensive validation of the predictions by the finite element models, since thousand of points are tracked along the femoral neck and trochanter region, i.e., the sites that are most critical for femur fracture. Moreover, strain measurement biases due to the strain gage reinforcement effect, were avoided. The combined experimental numerical approach proved to be ready for application to in-vitro tests of human cadaver femurs, thus helping to develop a suitable mechanistic fracture risk criterion. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:86 / 94
页数:9
相关论文
共 50 条
  • [31] Finite element vibration model validation of optical module and headlamp
    Roucoules, C.
    Sommerschuh, S.
    Cros, C.
    PROCEEDINGS OF ISMA 2008: INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING, VOLS. 1-8, 2008, : 1783 - 1793
  • [32] Study on validation method for femur finite element model under multiple loading conditions
    Guan, Fengjiao
    Zhang, Guanjun
    Liu, Jie
    Wang, Shujing
    Luo, Xu
    2017 INTERNATIONAL SYMPOSIUM ON APPLICATION OF MATERIALS SCIENCE AND ENERGY MATERIALS (SAMSE 2017), 2018, 322
  • [33] Validation of a three dimensional finite element model of a femur with a customized hip implant.
    Couteau, B
    Labey, L
    Hobatho, MC
    Vander Sloten, J
    Arlaud, JY
    Brignola, JC
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 147 - 154
  • [34] Experimental validation of a porohyperelastic finite element model of the annulus fibrosus
    Duncan, NA
    Lotz, JC
    COMPUTER METHODS IN BIOMECHANICS & BIOMEDICAL ENGINEERING - 2, 1998, : 527 - 534
  • [35] Experimental validation of a finite element model of a human cadaveric tibia
    Gray, Hans A.
    Taddei, Fulvia
    Zavatsky, Amy B.
    Cristofolini, Luca
    Gill, Harinderjit S.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (03):
  • [36] Experimental validation of a finite-element model updating procedure
    Kanev, S.
    Weber, F.
    Verhaegen, M.
    JOURNAL OF SOUND AND VIBRATION, 2007, 300 (1-2) : 394 - 413
  • [37] Model validation using iterative finite element model updating
    Bruns, M.
    Hofmeister, B.
    Huebler, C.
    Rolfes, R.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING (ISMA2020) / INTERNATIONAL CONFERENCE ON UNCERTAINTY IN STRUCTURAL DYNAMICS (USD2020), 2020, : 1951 - 1960
  • [38] Experimental Validation of Finite Element Models of Intact and Implanted Composite Hemipelvises Using Digital Image Correlation
    Ghosh, Rajesh
    Gupta, Sanjay
    Dickinson, Alexander
    Browne, Martin
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (08):
  • [39] Finite element model updating using FRF measurements
    Asma, F
    Bouazzouni, A
    SHOCK AND VIBRATION, 2005, 12 (05) : 377 - 388
  • [40] Experimental validation of finite element modeling
    Vogel, D
    Jian, C
    De Wolf, I
    BENEFITING FROM THERMAL AND MECHANICAL SIMULATION IN MICRO-ELECTRONICS, 2000, : 113 - 133