Experimental validation of finite element model for proximal composite femur using optical measurements

被引:66
|
作者
Grassi, Lorenzo [1 ,2 ]
Vaananen, Sami P. [3 ]
Yavari, Saber Amin [4 ]
Weinans, Harrie [4 ,5 ]
Jurvelin, Jukka S. [3 ]
Zadpoor, Amir A. [4 ]
Isaksson, Hanna [1 ,2 ]
机构
[1] Lund Univ, Div Solid Mech, Lund, Sweden
[2] Lund Univ, Dept Orthoped, Lund, Sweden
[3] Univ Eastern Finland, Dept Appl Phys, Kuopio, Finland
[4] Delft Univ Technol, Fac Mech Maritime & Mat Engn, Delft, Netherlands
[5] Erasmus MC, Dept Orthoped, Rotterdam, Netherlands
基金
芬兰科学院; 瑞典研究理事会;
关键词
Digital image correlation; Composite femur; Finite element; Bone fracture; DIGITAL-IMAGE-CORRELATION; STRAIN DISTRIBUTION; HIP-FRACTURES; BONE; OSTEOPOROSIS; ACCURACY; STRENGTH; MECHANICS; DENSITY; WOMEN;
D O I
10.1016/j.jmbbm.2013.02.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patient-specific finite element models have been used to predict femur strength and fracture risk in individuals. Validation of the adopted finite element modelling procedure against mechanical testing data is a crucial step when aiming for clinical applications. The majority of the works available in literature used data from strain gages to validate the model, thus having up to 15 experimental measurements. Optical techniques, such as digital image correlation, can help to improve the models by providing a continuous field of deformation data over a femoral surface. The main objective of this study was to validate finite element models of six composite femora against strain data from digital image correlation, obtained during fracture tests performed in quasi-axial loading configuration. The finite element models were obtained from CT scans, by means of a semi-automatic segmentation. The principal strains both during the elastic phase and close to the fracture were compared, and showed a correlation coefficient close to 0.9. In the linear region, the slope and intercept were close to zero and unity, while for the case when fracture load was simulated, the slope decreased somewhat. The accuracy of the obtained results is comparable with the state-of-the-art literature, with the significant improvement of having around 50,000 data points for each femur. This large number of measurements allows a more comprehensive validation of the predictions by the finite element models, since thousand of points are tracked along the femoral neck and trochanter region, i.e., the sites that are most critical for femur fracture. Moreover, strain measurement biases due to the strain gage reinforcement effect, were avoided. The combined experimental numerical approach proved to be ready for application to in-vitro tests of human cadaver femurs, thus helping to develop a suitable mechanistic fracture risk criterion. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:86 / 94
页数:9
相关论文
共 50 条
  • [21] A Robust 3D Finite Element Simulation of Human Proximal Femur Progressive Fracture Under Stance Load with Experimental Validation
    Ridha Hambli
    Samir Allaoui
    Annals of Biomedical Engineering, 2013, 41 : 2515 - 2527
  • [22] Validation of the finite element model of the femur and a novel internal distractible plate system
    Jung, Tae-Gon
    Han, Dong-Wook
    Suh, Seung Woo
    Yang, Jae-Hyuk
    Lee, Sung-Jae
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2013, 14 (04) : 657 - 662
  • [23] A Robust 3D Finite Element Simulation of Human Proximal Femur Progressive Fracture Under Stance Load with Experimental Validation
    Hambli, Ridha
    Allaoui, Samir
    ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (12) : 2515 - 2527
  • [24] Finite element analysis of CT based femur model using finite element program PAK
    Vulovic, S.
    Korunovic, N.
    Trajanovic, M.
    Grujovic, N.
    Vitkovic, N.
    JOURNAL OF THE SERBIAN SOCIETY FOR COMPUTATIONAL MECHANICS, 2011, 5 (02) : 160 - 166
  • [25] A CONDUCTIVE COOLING SCHEME FOR BONE AUGMENTATION OF THE PROXIMAL FEMUR WITH PMMA: AN EXPERIMENTAL AND FINITE ELEMENT STUDY
    Bakhtiarinejad, Mahsan
    Farvardin, Amirhossein
    Chamani, Alireza
    Armand, Mehran
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 3, 2020,
  • [26] Finite Element Validation on Adhesive Joint for Composite Fuselage Model
    Mustapha, F.
    Shahrjerdi, A.
    Sim, N. W.
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2012, 34 (01) : 69 - 74
  • [27] A quasi-brittle continuum damage finite element model of the human proximal femur based on element deletion
    Ridha Hambli
    Medical & Biological Engineering & Computing, 2013, 51 : 219 - 231
  • [28] A quasi-brittle continuum damage finite element model of the human proximal femur based on element deletion
    Hambli, Ridha
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2013, 51 (1-2) : 219 - 231
  • [29] The Impact of Coronal Configuration of the Proximal Femur on its Mechanical Properties and the Validation of a New Theoretical Model: Finite Element Analysis and Biomechanical Examination
    Zhang, Lijia
    Zhu, Baozhang
    Chen, Liwan
    Wang, Wenqing
    Zhang, Xiaoyong
    Zhang, Jianguo
    ORTHOPAEDIC SURGERY, 2023, 15 (01) : 62 - 69
  • [30] Finite element model of the proximal femur under consideration of the hip centralizing forces of the iliotibial tract
    Birnbaum, K.
    Pandorf, T.
    CLINICAL BIOMECHANICS, 2011, 26 (01) : 58 - 64