Moisture buffering effect of hygroscopic materials under wall moisture transfer

被引:7
|
作者
Yang, Ming [1 ]
Kong, Fanhong [1 ]
He, Xuancheng [1 ]
机构
[1] Cent South Univ, Sch Energy Sci & Engn, Changsha 410075, Hunan, Peoples R China
关键词
Hygroscopic material; Moisture buffering; Wall; Interior finish; EnergyPlus;
D O I
10.1177/1420326X20975835
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Hygroscopic material can moderate the indoor humidity variation due to its moisture buffering effect. This effect would change when used as interior finish mainly due to air exchange and wall moisture transfer. The author focused on clarifying the extent of the wall''s influence on indoor moisture buffering and building humidity environment. A room model was established and the situation of no wall moisture transfer was simulated by adding a vapour barrier between the interior finish and the wall. Comparing this result with wall moisture transfer, the moisture buffering effect of the wall can be quantitatively analysed. The results verify that the buffering effect and the humidity environment, especially the seasonal buffering, change with the wall moisture transfer. The wall has great impacts on buffering in the cases of thin interior finish, high moisture production and low ventilation. Because the layer under the hygroscopic material also has buffering capacity, the difference of using various thicknesses of material is not obvious. Frequent ventilation reduces the buffering effect but improves the RH optimality.
引用
收藏
页码:80 / 95
页数:16
相关论文
共 50 条
  • [41] Development of a moisture transfer calculation method of hygroscopic material plate in buildings
    Wan, Hang
    Huang, Gongsheng
    Xu, Xinhua
    BUILDING AND ENVIRONMENT, 2018, 142 : 398 - 413
  • [42] Effect of Moisture Content on Thermal Conductivity of Exterior Wall Insulation Materials
    School of Civil Engineering, Hebei University of Engineering, Handan
    056038, China
    不详
    100084, China
    Jianzhu Cailiao Xuebao, 1600, 6 (986-990):
  • [43] A CONTRIBUTION TO THE DEVELOPMENT OF MOISTURE MEASURING OF VACUUM-DRIED HYGROSCOPIC MATERIALS
    Cikic, Ante
    Samardzic, Ivan
    Stoic, Antun
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2013, 20 (01): : 137 - 145
  • [44] The dynamic thermal and moisture transfer properties of hygroscopic generated bamboo fibre
    Wu Haiyan
    Xie Hong
    Zhang Weiyuan
    PROCEEDINGS OF THE 2007 INTERNATIONAL CONFERENCE ON ADVANCED FIBERS AND POLYMER MATERIALS VOLS 1 AND 2, 2007, : 805 - 808
  • [45] Heat and moisture transfer in the wall of cooling towers
    Korzeniowski, Robert
    Prace Naukowe Instytutu Budownictwa Politechniki Wroclawskiej, 2000, (78): : 109 - 116
  • [46] STUDY ON THE EFFECT OF WOOD MOISTURE CONTENT ON PERMEABILITY IN THE HYGROSCOPIC RANGE
    王金满
    冯锐
    高广学
    Journal of Northeast Forestry University, 1994, (01) : 82 - 87
  • [47] An unsaturated flow of moisture in porous hygroscopic media at low moisture contents
    Kolhapure, NH
    Venkatesh, KV
    CHEMICAL ENGINEERING SCIENCE, 1997, 52 (19) : 3383 - 3392
  • [48] Heat and moisture transfer properties of mud wall
    Moriyama, Naoya
    Takada, Satoru
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 1495 - 1500
  • [49] MOISTURE ISOTHERMS OF HYGROSCOPIC POROUS SOLIDS
    ELSABAAWI, M
    PEI, DCT
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1977, 16 (03): : 321 - 326
  • [50] Moisture buffering and effect of ventilation rate and volume rate of hygrothermal materials in a single room under steady state exterior conditions
    Yoshino, H.
    Mitamura, T.
    Hasegawa, K.
    BUILDING AND ENVIRONMENT, 2009, 44 (07) : 1418 - 1425