Three-dimensional analysis of pulmonary venous ostial and antral anatomy: Implications for balloon catheter-based pulmonary vein isolation

被引:52
|
作者
Ahmed, J
Sohal, S
Malchano, ZJ
Holmvang, G
Ruskin, JN
Reddy, VY
机构
[1] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Cardiac Arrhythmia Serv, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Dept Radiol,Cardiac MRI Unit, Boston, MA 02114 USA
[3] Boston Univ, Sch Med, Boston Med Ctr, Boston, MA 02215 USA
[4] Michigan State Med Sch, Lansing, MI USA
关键词
electrophysiology; magnetic resonance imaging; left atrium; pulmonary veins; atrial fibrillation; ablation; balloon catheter;
D O I
10.1111/j.1540-8167.2005.00339.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Balloon ablation catheters using various energy sources are being developed to perform pulmonary vein (PV) isolation to treat atrial fibrillation. Prior evaluations of 2D CT/MR images are limited by the frequent elliptical shape of the PV ostia, the nonorthogonal orientation of the PVs to the left atrial (LA) chamber, and difficulty in appreciating through-slice curvature. To provide anatomical data relevant to balloon catheter ablation, 3D surface reconstructions of LA-PVs were generated and analyzed to define ostial architecture and size. Methods and Results: Using MRI datasets obtained from 101 paroxysmal AF patients, the LA-PVs were segmented to generate 3D LA-PV surface reconstructions. Using both external and endoluminal projections, the PV ostial and antral regions were identified and evaluated. In the left PVs, a common left-sided ostium was identified in 94 patients, with an ostial circumference of 95 +/- 15 mm. Branching of the left PVs occurred 0-5 mm away from the common left ostium in 43 patients (43%), 5-15 mm away from the common os in 37 patients (37%), and > 15 mm away from the common os in 14 patients (14%). In patients with either distinct left PV ostia, or common os < 15 mm (87 patients), the individual LSPV/LIPV ostial circumferences were 67 +/- 12 mm and 58 +/- 9 mm, respectively. Mean left antral circumference was 114 +/- 17 mm. In the right PVs, the ostial circumferences of the RSPV/RIPV were 68 +/- 11 mm and 66 +/- 11 mm, respectively. Mean right antral circumference was 107 +/- 19 mm. Assuming ideal deformation of the LA chamber anatomy, the minimal diameters of a balloon ablation catheter required to isolate 95% of the RSPV, RIPV, LSPV, LIPV, LCPV, left antrum, and right antrum are 29 mm, 28 mm, 29 mm, 24 mm, 40 mm, 46 mm, and 47 mm, respectively. Conclusion: Analysis of 3D surface reconstructions of LA-PV anatomy reveals that balloon catheter-based ablation of the PVs is likely feasible in most patients, but balloon ablation of the common PV antra would be problematic.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 50 条
  • [21] Pulmonary vein isolation and left atrial catheter ablation using a three-dimensional navigation system for the treatment of atrial fibrillation
    Macle, Laurent
    Novak, Paul
    Khairy, Paul
    Thibault, Bernard
    Talajic, Mario
    Dubuc, Marc
    Roy, Denis
    Guerra, Peter G.
    CANADIAN JOURNAL OF CARDIOLOGY, 2009, 25 (06) : E169 - E172
  • [22] Pulmonary vein disconnection using the LocaLisa three-dimensional nonfluoroscopic catheter imaging system
    Macle, L
    Jaïs, P
    Scavée, C
    Weerasooriya, R
    Hocini, M
    Shah, DC
    Raybaud, F
    Choi, KJ
    Clémenty, J
    Haïssaguerre, M
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2003, 14 (07) : 693 - 697
  • [23] Pulmonary vein isolation with the radiofrequency balloon catheter: a single centre prospective study
    Del Monte, Alvise
    Almorad, Alexandre
    Pannone, Luigi
    Della Rocca, Domenico Giovanni
    Bisignani, Antonio
    Monaco, Cinzia
    Mouram, Sahar
    Ramak, Robbert
    Gauthey, Anais
    Overeinder, Ingrid
    Bala, Gezim
    Sorgente, Antonio
    Stroker, Erwin
    Sieira, Juan
    Brugada, Pedro
    La Meir, Mark
    Chierchia, Gian-Battista
    de Asmundis, Carlo
    EUROPACE, 2023, 25 (03): : 896 - 904
  • [24] Autonomic Response during Pulmonary Vein Isolation using a Hot Balloon Catheter
    Takeda, Hiroshi
    Sohara, Hiroshi
    Ueno, Hidaki
    Oda, Toshimichi
    Satake, Shutaro
    Hiura, Norikazu
    CIRCULATION, 2008, 118 (18) : S677 - S677
  • [25] Early results of the Heliostar™ RF balloon ablation catheter for pulmonary vein isolation
    Breitenstein, A.
    Kanthasamy, V.
    Hofer, D.
    Schilling, R. J.
    Hunter, R. J.
    Finlay, M.
    SWISS MEDICAL WEEKLY, 2022, 152 : 51S - 51S
  • [26] Left atrial flutter after segmental ostial radiofrequency catheter ablation for pulmonary vein isolation
    Oral, H
    Knight, BP
    Morady, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (06): : 1417 - 1419
  • [27] Catheter-based renal denervation as adjunct to pulmonary vein isolation for treatment of atrial fibrillation: a systematic review and meta-analysis
    Ukena, Christian
    Becker, Nicolas
    Pavlicek, Valerie
    Millenaar, Dominic
    Ewen, Sebastian
    Linz, Dominik
    Steinberg, Jonathan S.
    Boehm, Michael
    Mahfoud, Felix
    JOURNAL OF HYPERTENSION, 2020, 38 (05) : 783 - 790
  • [28] The importance of antral pulmonary vein isolation during visually-guided laser balloon ablation
    Wissner, Erik
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (07) : 1606 - 1607
  • [29] Pulmonary venous anatomy predicts recurrent arrhythmia after pulmonary vein antrum isolation for atrial fibrillation
    Jacob, Ron
    Patel, Dimpi
    Lieber, Michael
    Williams, Michelle
    Natale, Andrea
    Sola, Srikanth
    CIRCULATION, 2007, 116 (16) : 562 - 562
  • [30] The durability of pulmonary vein isolation using the visually guided laser balloon catheter: Multicenter results of pulmonary vein remapping studies
    Dukkipati, Srinivas R.
    Neuzil, Petr
    Kautzner, Josef
    Petru, Jan
    Wichterle, Dan
    Skoda, Jan
    Cihak, Robert
    Peichl, Petr
    Dello Russo, Antonio
    Pelargonio, Gemma
    Tondo, Claudio
    Natale, Andrea
    Reddy, Vivek Y.
    HEART RHYTHM, 2012, 9 (06) : 919 - 925