The Effect of Attenuation and Scatter Correction in Rat Brain PET

被引:6
|
作者
Yu, A. Ram [1 ,2 ]
Kim, Jin Su [1 ]
Moon, Jisook [3 ]
Kim, Hee Joung [2 ]
Lim, Sang Moo [1 ]
Kim, Kyeong Min [1 ]
机构
[1] Korea Inst Radiol & Med Sci, Mol Imaging Res Ctr, Seoul 139706, South Korea
[2] Yonsei Univ, Dept Radiol Sci, Coll Hlth Sci, Wonju 220710, South Korea
[3] CHA Univ, Dept Appl Biomed Sci, Coll Life Sci, Seoul 135081, South Korea
关键词
Attenuation correction; brain PET; positron emission tomography; scatter correction; SPECT; MODEL;
D O I
10.1109/TNS.2012.2230338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attenuation correction (AC) and scatter correction (SC) are problematic issues for animal positron emission tomography (PET). In this study, the effects of AC and SC were assessed using PET on a phantom and actual rat brain. Transmission (TX) was performed using Co-57 for 15 min. After a 15 min TX scan, emission (EM) PET was performed in list mode for 1 h. To assess the effects of AC and SC, the spillover ratio (SOR) was measured using a rat-sized NEMA NU4 image-quality phantom; statistical parametric mapping (SPM) was performed to assess the effects of AC and SC in the rat brain using F-18-FDG (FDG). In addition, the binding potential (BP) was compared for F-18-FP-CIT (FP-CIT) PET. SPM was used to compare PET images to which AC and SC were applied, and BP was used for FP-CIT PET. The SORs of air and water decreased after AC and SC. SPM for FDG PET after AC showed a significant increase in FDG-measured activity in the cerebellum and occipital cortex. After AC/SC, a significant decrease in FDG-measured activity was observed in the frontal and temporal cortices. For FP-CIT PET of the rat brain, the BP decreased by 26% after AC because the FP-CIT uptake increased more in the cerebellum than in the striatum owing to AC. After AC and SC, the mean BP increased by 61%. AC and AC/SC were found to be necessary components of the artifact correction process for both FDG PET and FP-CIT PET of rat brains.
引用
收藏
页码:751 / 757
页数:7
相关论文
共 50 条
  • [1] Effect of Scatter Correction When Comparing Attenuation Maps: Application to Brain PET/MR
    Burgos, Ninon
    Thielemans, Kris
    Cardoso, M. Jorge
    Markiewicz, Pawel
    Jiao, Jieqing
    Dickson, John
    Duncan, John S.
    Atkinson, David
    Arridge, Simon R.
    Hutton, Brian F.
    Ourselin, Sebastien
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [2] AN INVESTIGATION OF SCATTER IN ATTENUATION CORRECTION FOR PET
    DIGBY, WM
    HOFFMAN, EJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1038 - 1042
  • [3] Attenuation and scatter correction for rat brain PET: Change of glucose uptake in FDG PET and binding potential in FP-CIT PET
    Kim, Jin Su
    Kim, Kyeong Min
    Lee, Wonho
    Yu, A. Ram
    Kim, Jong Guk
    Woo, Sang-Keun
    Park, JiAe
    Cheon, Gi Jeong
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [4] Attenuation Correction for a Generalized Scatter Reconstruction in PET
    Sun, Hongyan
    Pisotrius, Stephen
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [5] Accuracy of Scatter and Attenuation Correction in PET Imaging
    Chang, T.
    Chang, G.
    Clark, J.
    Mawlawi, O.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [6] The effect of normalization, CT attenuation, and scatter corrections on quantitative rat brain imaging with FDG-PET
    Jaiswal, Shalini
    Wilson, Colin
    Selwyn, Reed
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [7] The effect of normalization, CT attenuation, and scatter corrections on quantitative rat brain imaging with FDG-PET
    Jaiswal, Shalini
    Wilson, Colin
    Selwyn, Reed
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [8] Simultaneous attenuation and scatter correction by restoration in PET imaging
    Bentourkia, M
    Sarrhini, O
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3712 - 3715
  • [9] Scatter Correction Requirements for Likelihood-Based Attenuation Artifact Correction in PET
    Laymon, C. M.
    Bowsher, J. E.
    Carney, J. P. J.
    Blodgett, T. M.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2151 - 2154
  • [10] Scatter, attenuation and detector response correction in brain SPECT.
    Shinohara, H
    Matsuoka, M
    Yamamoto, T
    Niio, Y
    Kuniyasu, Y
    Hashimoto, T
    Takahashi, M
    Yokoi, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 302P - 302P