The Effect of Attenuation and Scatter Correction in Rat Brain PET

被引:6
|
作者
Yu, A. Ram [1 ,2 ]
Kim, Jin Su [1 ]
Moon, Jisook [3 ]
Kim, Hee Joung [2 ]
Lim, Sang Moo [1 ]
Kim, Kyeong Min [1 ]
机构
[1] Korea Inst Radiol & Med Sci, Mol Imaging Res Ctr, Seoul 139706, South Korea
[2] Yonsei Univ, Dept Radiol Sci, Coll Hlth Sci, Wonju 220710, South Korea
[3] CHA Univ, Dept Appl Biomed Sci, Coll Life Sci, Seoul 135081, South Korea
关键词
Attenuation correction; brain PET; positron emission tomography; scatter correction; SPECT; MODEL;
D O I
10.1109/TNS.2012.2230338
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Attenuation correction (AC) and scatter correction (SC) are problematic issues for animal positron emission tomography (PET). In this study, the effects of AC and SC were assessed using PET on a phantom and actual rat brain. Transmission (TX) was performed using Co-57 for 15 min. After a 15 min TX scan, emission (EM) PET was performed in list mode for 1 h. To assess the effects of AC and SC, the spillover ratio (SOR) was measured using a rat-sized NEMA NU4 image-quality phantom; statistical parametric mapping (SPM) was performed to assess the effects of AC and SC in the rat brain using F-18-FDG (FDG). In addition, the binding potential (BP) was compared for F-18-FP-CIT (FP-CIT) PET. SPM was used to compare PET images to which AC and SC were applied, and BP was used for FP-CIT PET. The SORs of air and water decreased after AC and SC. SPM for FDG PET after AC showed a significant increase in FDG-measured activity in the cerebellum and occipital cortex. After AC/SC, a significant decrease in FDG-measured activity was observed in the frontal and temporal cortices. For FP-CIT PET of the rat brain, the BP decreased by 26% after AC because the FP-CIT uptake increased more in the cerebellum than in the striatum owing to AC. After AC and SC, the mean BP increased by 61%. AC and AC/SC were found to be necessary components of the artifact correction process for both FDG PET and FP-CIT PET of rat brains.
引用
收藏
页码:751 / 757
页数:7
相关论文
共 50 条
  • [31] Attenuation compensation and Compton scatter correction: Improvement in brain SPECT image quality
    Naimi, A
    Papazyan, J
    Allaoua, M
    Buchegger, F
    Slosman, DO
    RADIOLOGY, 1996, 201 : 1486 - 1486
  • [32] A method for attenuation and scatter correction of brain SPECT based on computed tomography images
    Larsson, A
    Johansson, L
    Sundström, T
    Åhlström, KR
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (04) : 411 - 420
  • [34] Low Dose CT Attenuation Correction for Brain imaging with PET
    Bonab, A. A.
    Alpert, N. M.
    Liu, B.
    Fischman, A. J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S258 - S258
  • [35] Automated PET/CT Brain Registration for Accurate Attenuation Correction
    Khurshid, Khawar
    Berger, Kevin L.
    McGough, Robert J.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5805 - 5808
  • [36] An automatic pipeline for PET/MRI attenuation correction validation in the brain
    Mahdjoub Hamdi
    Chunwei Ying
    Hongyu An
    Richard Laforest
    EJNMMI Physics, 10
  • [37] An automatic pipeline for PET/MRI attenuation correction validation in the brain
    Hamdi, Mahdjoub
    Ying, Chunwei
    An, Hongyu
    Laforest, Richard
    EJNMMI PHYSICS, 2023, 10 (01)
  • [38] Brain PET-MR attenuation correction with deep learning
    Yaakub, S. N.
    McGinnity, C. J.
    Beck, K.
    Merida, I.
    Dunston, E.
    Muffoletto, M.
    Qureshi, A.
    Bhattacharya, S.
    MacKewn, J.
    Hammers, A.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2019, 39 : 600 - 601
  • [39] Evaluation of calculated attenuation correction method in brain PET imaging
    Da Costa, A.
    Cassol, E.
    Arribarat, G.
    Peran, P.
    Blanc, P.
    Hitzel, A.
    Payoux, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S561 - S561
  • [40] Automated PET attenuation correction model for functional brain imaging
    Weinzapfel, BT
    Hutchins, GD
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (03) : 483 - 491