Determination of Lead(II) Using Screen-Printed Bismuth-Antimony Film Electrode

被引:25
|
作者
Chen, Chen [1 ]
Niu, Xiangheng [1 ]
Chai, Yan [1 ]
Zhao, Hongli [1 ]
Lan, Minbo [1 ,2 ]
Zhu, Yonggang [3 ,4 ]
Wei, Gang [5 ]
机构
[1] E China Univ Sci & Technol, Shanghai Key Lab Funct Mat Chem, Shanghai 200237, Peoples R China
[2] E China Univ Sci & Technol, Minist Educ, Key Lab Ultrafine Mat, Shanghai 200237, Peoples R China
[3] CSIRO Mat Sci & Engn, Clayton, Vic 3169, Australia
[4] Melbourne Ctr Nanofabricat, Clayton, Vic 3168, Australia
[5] CSIRO Mat Sci & Engn, Lindfield, NSW 2070, Australia
关键词
Bismuth-antimony film; Screen-printed electrodes; Stripping voltammetry; Lead(II) detection; ANODIC-STRIPPING VOLTAMMETRY; TRACE HEAVY-METALS; CARBON-PASTE ELECTRODE; ICP-AES; POWDER; IONS; CD; PB; SPECTROMETRY; BIOSENSORS;
D O I
10.1002/elan.201200625
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents a disposable bismuth-antimony film electrode fabricated on screen-printed electrode (SPE) substrates for lead(II) determination. This bismuth-antimony film screen-printed electrode (Bi-SbSPE) is simply prepared by simultaneously in situ depositing bismuth(III) and antimony(III) with analytes on the homemade SPE. The Bi-SbSPE can provide an enhanced electrochemical stripping signal for lead(II) compared to bismuth film screen-printed electrodes (BiSPE), antimony film screen-printed electrodes (SbSPE) and bismuth-antimony film glassy carbon electrodes (Bi-SbGC). Under optimized conditions, the Bi-SbSPE exhibits attractive linear responses towards lead(II) with a detection limit of 0.07 mu g/L. The Bi-SbSPE has been demonstrated successfully to detect lead in river water sample.
引用
收藏
页码:1446 / 1452
页数:7
相关论文
共 50 条
  • [11] Resolving the copper interference effect on the stripping chronopotentiometric response of lead(II) obtained at bismuth film screen-printed electrode
    Kadara, RO
    Tothill, LE
    TALANTA, 2005, 66 (05) : 1089 - 1093
  • [12] Determination of Antimony (III) in Real Samples by Anodic Stripping Voltammetry Using a Mercury Film Screen-Printed Electrode
    Dominguez-Renedo, Olga
    Gomez Gonzalez, M. Jesus
    Julia Arcos-Martinez, M.
    SENSORS, 2009, 9 (01) : 219 - 231
  • [13] Voltammetric Determination of Pb(II) and Cd(II) Ions in Well Water Using a Sputtered Bismuth Screen-Printed Electrode
    Sosa, Velia
    Serrano, Nulria
    Arino, Cristina
    Diaz-Cruz, Jose Manuel
    Esteban, Miquel
    ELECTROANALYSIS, 2014, 26 (10) : 2168 - 2172
  • [14] Bismuth as Internal Standard for Reliable Detection of Trace Lead at Screen-Printed Electrode
    Zhang, Haiyun
    Lin, Mingyue
    Zhang, Qing
    Han, Haitao
    Pan, Dawei
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (16) : 5217 - 5222
  • [15] Electrochemical Determination of 2,4-Dichlorophenoxyacetic Acid using Bismuth Film Modified Screen-printed Carbon Electrode
    Niguso, Temesgen Takele
    Soreta, Tesfaye Refera
    Woldemariam, Ephrem Tilahun
    SOUTH AFRICAN JOURNAL OF CHEMISTRY-SUID-AFRIKAANSE TYDSKRIF VIR CHEMIE, 2018, 71 : 160 - 165
  • [16] Pb(II) Determination in a Single Drop Using a Modified Screen-Printed Electrode
    Zurga, Nika
    Majer, David
    Finsgar, Matjaz
    CHEMOSENSORS, 2021, 9 (02) : 1 - 10
  • [17] Sensitive Stripping Determination of Cadmium(II) and Lead(II) on Disposable Graphene Modified Screen-Printed Electrode
    Chao Huangfu
    Fu, Liang
    Li, Yuzhi
    Li, Xueling
    Du, Haijun
    Ye, Jianshan
    ELECTROANALYSIS, 2013, 25 (09) : 2238 - 2243
  • [18] Bismuth Film Combined with Screen-Printed Electrode as Biosensing Platform for Phenol Detection
    Merkoci, Arben
    Anik, Ulku
    Cevik, Serdar
    Cubukcu, Meliha
    Guix, Maria
    ELECTROANALYSIS, 2010, 22 (13) : 1429 - 1436
  • [19] A screen-printed carbon electrode modified with a bismuth film and gold nanoparticles for simultaneous stripping voltammetric determination of Zn(II), Pb(II) and Cu(II)
    Lu, Zhiwei
    Zhang, Junjun
    Dai, Wanlin
    Lin, Xueni
    Ye, Jiaping
    Ye, Jianshan
    MICROCHIMICA ACTA, 2017, 184 (12) : 4731 - 4740
  • [20] Antimony film screen-printed carbon electrode for stripping analysis of Cd(II), Pb(II), and Cu(II) in natural samples
    Sosa, Velia
    Barcelo, Cristian
    Serrano, Nuria
    Arino, Cristina
    Manuel Diaz-Cruz, Jose
    Esteban, Miquel
    ANALYTICA CHIMICA ACTA, 2015, 855 : 34 - 40