Positional Accuracy of Treating Multiple Versus Single Vertebral Metastases With Stereotactic Body Radiotherapy

被引:13
|
作者
Chang, Joe H. [1 ]
Sangha, Arnjeet [1 ]
Hyde, Derek [2 ]
Soliman, Hany [1 ]
Myrehaug, Sten [1 ]
Ruschin, Mark [1 ]
Lee, Young [1 ]
Sahgal, Arjun [1 ]
Korol, Renee [1 ]
机构
[1] Univ Toronto, Dept Radiat Oncol, Sunnybrook Odette Canc Ctr, Toronto, ON, Canada
[2] BC Canc Agcy, Sindi Ahluwalia Hawkins Ctr Southern Interior, Dept Med Phys, Kelowna, BC, Canada
关键词
radiotherapy; intensity modulated; image guided; radiosurgery; spine; cone beam computed tomography; CONE-BEAM CT; SPINAL METASTASES; RADIATION-THERAPY; MOTION; MARGINS; ERRORS; RISK; CORD;
D O I
10.1177/1533034616681674
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study is to determine whether stereotactic body radiotherapy for multiple vertebral metastases treated with a single isocenter results in greater intrafraction errors than stereotactic body radiotherapy for single vertebral metastases and to determine whether the currently used spinal cord planning organ at risk volume and planning target volume margins are appropriate. Intrafraction errors were assessed for 65 stereotactic body radiotherapy treatments for vertebral metastases. Cone beam computed tomography images were acquired before, during, and after treatment for each fraction. Residual translational and rotational errors in patient positioning were recorded and planning organ at risk volume and planning target volume margins were calculated in each direction using this information. The mean translational residual errors were smaller for single (0.4 (0.4) mm) than for multiple vertebral metastases (0.5 (0.7) mm; P = .0019). The mean rotational residual errors were similar for single (0.3 degrees (0.3 degrees) and multiple vertebral metastases (0.3 degrees (0.3 degrees); P = .862). The maximum calculated planning organ at risk volume margin in any direction was 0.83 mm for single and 1.22 for multiple vertebral metastases. The maximum calculated planning target volume margin in any direction was 1.4 mm for single and 1.9 mm for multiple vertebral metastases. Intrafraction errors were small for both single and multiple vertebral metastases, indicating that our strategy for patient immobilization and repositioning is robust. Calculated planning organ at risk volume and planning target volume margins were smaller than our clinically employed margins, indicating that our clinical margins are appropriate.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [41] Technique for stereotactic body radiotherapy for spinal metastases
    Foote, Matthew
    Letourneau, Daniel
    Hyde, Derek
    Massicotte, Eric
    Rampersaud, Raja
    Fehlings, Michael
    Fisher, Charles
    Lewis, Stephen
    La Macchia, Nancy
    Yu, Eugene
    Laperriere, Normand J.
    Sahgal, Arjun
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (02) : 276 - 279
  • [42] Stereotactic body radiotherapy for spinal metastases: a review
    Lanlan Guo
    Lixin Ke
    Ziyi Zeng
    Chuanping Yuan
    Ziwei Wu
    Lei Chen
    Lixia Lu
    Medical Oncology, 39
  • [43] Automated single-isocenter stereotactic body radiotherapy for multiple metastases from breast cancer: A case study
    Cilla, Savino
    Macchia, Gabriella
    Bonome, Paolo
    Pezzulla, Donato
    Romano, Carmela
    Boccardi, Mariangela
    Viola, Pietro
    Galietta, Erika
    Donati, Costanza M.
    Morganti, Alessio G.
    Deodato, Francesco
    MEDICAL DOSIMETRY, 2025, 50 (01) : 57 - 62
  • [44] Stereotactic body radiotherapy for painful spinal metastases: a decade of experience at a single institution
    Chou, Kuan-Nien
    Park, David J.
    Hori, Yusuke S.
    Persad, Amit R.
    Chuang, Cynthia F.
    Emrich, Sara C.
    Ustrzynski, Louisa
    Tayag, Armine
    Kumar, Kiran A.
    Usoz, Melissa
    Mendoza, Maria
    Rahimy, Elham
    Pollom, Erqi
    Soltys, Scott G.
    Lo, Cheng-Hsiang
    Chang, Steven D.
    JOURNAL OF NEUROSURGERY-SPINE, 2024, 41 (04) : 532 - 540
  • [45] Stereotactic body radiotherapy for lung metastases: retrospective analysis of a single-center
    Herrmann, H.
    Proksch, C.
    Dieckmann, K.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S666 - S666
  • [46] Stereotactic Body Radiotherapy for Adrenal Gland Metastases: Single-Center Experience
    Yaprak, Gokhan
    Isik, Naciye
    Gemici, Cengiz
    Demir, Harun
    Pekyurek, Melike
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (04): : 291 - 297
  • [47] VOLUMETRIC MODULATED ARC RADIOTHERAPY FOR RAPID DELIVERY OF STEREOTACTIC RADIOTHERAPY TO VERTEBRAL METASTASES
    Kuijper, I.
    Verbakel, W.
    Cuijpers, J.
    Haasbeek, N.
    Senan, S.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S90 - S90
  • [48] Single versus multiple session stereotactic body radiotherapy for spinal metastasis: the risk-benefit ratio
    Redmond, Kristin J.
    Sahgal, Arjun
    Foote, Matthew
    Knisely, Jonathan
    Gerszten, Peter C.
    Chao, Samuel T.
    Suh, John H.
    Sloan, Andrew E.
    Chang, Eric L.
    Machtay, Mitchell
    Lo, Simon S.
    FUTURE ONCOLOGY, 2015, 11 (17) : 2405 - 2415
  • [49] Single Versus Multiple Fractionated Stereotactic Spine Radiosurgery for Spinal Metastases
    Lai, S.
    Chen, Y. F.
    Xian, F. R.
    Hsu, F. M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S893 - S894
  • [50] Safety and efficacy of stereotactic body radiotherapy as primary treatment for vertebral metastases: a multi-institutional analysis
    Guckenberger, Matthias
    Mantel, Frederick
    Gerszten, Peter C.
    Flickinger, John C.
    Sahgal, Arjun
    Letourneau, Daniel
    Grills, Inga S.
    Jawad, Maha
    Fahim, Daniel K.
    Shin, John H.
    Winey, Brian
    Sheehan, Jason
    Kersh, Ron
    RADIATION ONCOLOGY, 2014, 9 : 226