Positional Accuracy of Treating Multiple Versus Single Vertebral Metastases With Stereotactic Body Radiotherapy

被引:13
|
作者
Chang, Joe H. [1 ]
Sangha, Arnjeet [1 ]
Hyde, Derek [2 ]
Soliman, Hany [1 ]
Myrehaug, Sten [1 ]
Ruschin, Mark [1 ]
Lee, Young [1 ]
Sahgal, Arjun [1 ]
Korol, Renee [1 ]
机构
[1] Univ Toronto, Dept Radiat Oncol, Sunnybrook Odette Canc Ctr, Toronto, ON, Canada
[2] BC Canc Agcy, Sindi Ahluwalia Hawkins Ctr Southern Interior, Dept Med Phys, Kelowna, BC, Canada
关键词
radiotherapy; intensity modulated; image guided; radiosurgery; spine; cone beam computed tomography; CONE-BEAM CT; SPINAL METASTASES; RADIATION-THERAPY; MOTION; MARGINS; ERRORS; RISK; CORD;
D O I
10.1177/1533034616681674
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study is to determine whether stereotactic body radiotherapy for multiple vertebral metastases treated with a single isocenter results in greater intrafraction errors than stereotactic body radiotherapy for single vertebral metastases and to determine whether the currently used spinal cord planning organ at risk volume and planning target volume margins are appropriate. Intrafraction errors were assessed for 65 stereotactic body radiotherapy treatments for vertebral metastases. Cone beam computed tomography images were acquired before, during, and after treatment for each fraction. Residual translational and rotational errors in patient positioning were recorded and planning organ at risk volume and planning target volume margins were calculated in each direction using this information. The mean translational residual errors were smaller for single (0.4 (0.4) mm) than for multiple vertebral metastases (0.5 (0.7) mm; P = .0019). The mean rotational residual errors were similar for single (0.3 degrees (0.3 degrees) and multiple vertebral metastases (0.3 degrees (0.3 degrees); P = .862). The maximum calculated planning organ at risk volume margin in any direction was 0.83 mm for single and 1.22 for multiple vertebral metastases. The maximum calculated planning target volume margin in any direction was 1.4 mm for single and 1.9 mm for multiple vertebral metastases. Intrafraction errors were small for both single and multiple vertebral metastases, indicating that our strategy for patient immobilization and repositioning is robust. Calculated planning organ at risk volume and planning target volume margins were smaller than our clinically employed margins, indicating that our clinical margins are appropriate.
引用
收藏
页码:231 / 237
页数:7
相关论文
共 50 条
  • [31] Stereotactic Body Radiotherapy for Spinal and Bone Metastases
    Bhattacharya, I. S.
    Hoskin, P. J.
    CLINICAL ONCOLOGY, 2015, 27 (05) : 298 - 306
  • [32] Stereotactic Body Radiotherapy in the Treatment of Adrenal Metastases
    Ahmed, Kamran A.
    Barney, Brandon M.
    Macdonald, O. Kenneth
    Miller, Robert C.
    Garces, Yolanda I.
    Laack, Nadia N.
    Haddock, Michael G.
    Foote, Robert L.
    Olivier, Kenneth R.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2013, 36 (05): : 509 - 513
  • [33] Stereotactic body radiotherapy for painful spinal metastases
    Sahgal, Arjun
    Brundage, Michael
    Ding, Keyue
    Parulekar, Wendy R.
    LANCET ONCOLOGY, 2021, 22 (09): : E385 - E385
  • [34] Stereotactic Body Radiotherapy (SBRT) for Spinal Metastases
    Kretzler, A. E.
    Bassetti, M.
    Balter, J. M.
    Tsien, C. I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S504 - S504
  • [35] Stereotactic Body Radiotherapy for Sarcoma Pulmonary Metastases
    Lebow, E. S.
    Lobaugh, S.
    Zhang, Z.
    Dickson, M.
    Thornton, K.
    Rosenbaum, E.
    D'Angelo, S.
    Nacev, B.
    Shepherd, A. F.
    Shaverdian, N.
    Wolden, S. L.
    Wu, A. J.
    Gelblum, D.
    Simone, C. B., II
    Gomez, D. R.
    Alektiar, K. M.
    Tap, W. D.
    Rimner, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E607 - E608
  • [36] Stereotactic body radiotherapy treatment of extracranial metastases
    Salama, Joseph K.
    Kirkpatrick, John P.
    Yin, Fang-Fang
    NATURE REVIEWS CLINICAL ONCOLOGY, 2012, 9 (11) : 654 - 665
  • [37] Stereotactic body radiotherapy for the treatment of spinal metastases
    Balagamwala, Ehsan H.
    Cherian, Sheen
    Angelov, Lilyana
    Suh, John H.
    Djemil, Toufik
    Lo, Simon S.
    Sahgal, Arjun
    Chang, Eric
    Teh, Bin S.
    Chao, Samuel T.
    JOURNAL OF RADIATION ONCOLOGY, 2012, 1 (03) : 255 - 265
  • [38] Stereotactic body radiotherapy treatment of extracranial metastases
    Joseph K. Salama
    John P. Kirkpatrick
    Fang-Fang Yin
    Nature Reviews Clinical Oncology, 2012, 9 : 654 - 665
  • [39] Stereotactic body radiotherapy for spinal metastases: a review
    Guo, Lanlan
    Ke, Lixin
    Zeng, Ziyi
    Yuan, Chuanping
    Wu, Ziwei
    Chen, Lei
    Lu, Lixia
    MEDICAL ONCOLOGY, 2022, 39 (05)
  • [40] Stereotactic Body Radiotherapy in the Treatment of Spinal Metastases
    Katsoulakis, Evangelia
    Kumar, Kiran
    Laufer, Ilya
    Yamada, Yoshiya
    SEMINARS IN RADIATION ONCOLOGY, 2017, 27 (03) : 209 - 217