Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study

被引:5
|
作者
Geckili, Onur [1 ]
Bilhan, Hakan [2 ]
Geckili, Esma [3 ]
Barca-Dayan, Ece [4 ]
Dayan, Cagatay [5 ]
Bural, Canan [1 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, 2nd Floor, TR-34093 Istanbul, Turkey
[2] Univ Witten Herdecke, Dept Periodontol, Fac Hlth, Sch Dent, Witten, Nordrhein Westf, Germany
[3] Istanbul Bilgi Univ, Dept Dent Serv Oral & Dent Hlth, Istanbul, Turkey
[4] Istanbul Univ, Fac Dent, Dept Periodontol, Istanbul, Turkey
[5] Istanbul Univ Cerrahpasa, Program Dent Technicians, Istanbul, Turkey
来源
关键词
Implantology; experimental design; osseointegration; RESONANCE FREQUENCY; LEARNING-CURVE; CASE SERIES; SUCCESS;
D O I
10.4317/medoral.22733
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The aim of this study was to investigate the clinicians' experience on maintaining the primary stability of implants with aggressive threads belonging to a novel dental implant system. Material and Methods: Three hundred implants with aggressive threads were inserted in fresh bovine ribs mimicking Type IV bone by five clinicians which were classified according to their previous experience of total number of implant insertion. An independent examiner measured the primary stability of all implants after insertion by using resonance frequency analysis (RFA), electronic percussive testing (EPT) and removal torque methods. Results: No significant differences were detected between the stability values measured by the clinicians (p> 0.05) except the Periotest values (PTVs) of the non-experienced clinician. PTVs of the non-experienced clinician were significantly higher than the PTVs of the expert and good clinicians (p<0.05). Significantly higher stability values were detected in the secondary insertion of the non-experienced clinician as compared to her initial insertion values (p<0.05). No significant differences were detected between the first and second measurements of the other clinicians (p> 0.05). Conclusions: Within the limitations of this ex-vivo study, it may be concluded that experience does not play an important role in maintaining the stability of implants with aggressive threads.
引用
收藏
页码:E254 / E259
页数:6
相关论文
共 50 条
  • [31] Evaluation of Primary Stability of Self-Tapping and Non-Self-Tapping Dental Implants. A 12-Week Clinical Study
    Markovic, Aleksa
    Luis Calvo-Guirado, Jose
    Lazic, Zoran
    Gomez-Moreno, Gerardo
    Calasan, Dejan
    Guardia, Javier
    Colic, Snjezana
    Aguilar-Salvatierra, Antonio
    Gacic, Bojan
    Delgado-Ruiz, Rafael
    Janjic, Bojan
    Misic, Tijana
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (03) : 341 - 349
  • [32] Initial Stability Measurements of Implants Using a New Magnetic Resonance Frequency Analyzer With Titanium Transducers: An Ex Vivo Study
    Bural, Canan
    Dayan, Cagatay
    Geckili, Onur
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (01) : 35 - 40
  • [33] New generation argon plasma coagulation in flexible endoscopy:: Ex vivo study and clinical experience
    Sumiyama, Kazuki
    Kaise, Mitsuru
    Kato, Masayuki
    Saito, Syouichi
    Goda, Kenichi
    Odagi, Isao
    Tamai, Naoto
    Tsukinaga, Shintaro
    Matsunaga, Kazuhiro
    Tajiri, Hisao
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2006, 21 (07) : 1122 - 1128
  • [34] Influence of primary stability and osteotomy technique on immediately loaded implants in the maxillary posterior region: An in vivo study
    Singh, I.
    Shetty, M.
    Hegde, C.
    Shetty, A.
    John, N.
    JOURNAL OF OSSEOINTEGRATION, 2022, 14 (04) : 246 - 253
  • [35] Evaluation of Stability with Early Loading Utilizing Blx Sla and Slactive Dental Implants: A Clinical Comparative Study
    Ibrahim, Ahmed Amer
    Hassan, Thair A. Lateef
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2022, 10 (02): : 231 - 235
  • [36] Primary stability of different implant macrodesigns in a sinus floor elevation simulated model: an ex vivo study
    Imai, Mikio
    Ogino, Yoichiro
    Tanaka, Hideaki
    Koyano, Kiyoshi
    Ayukawa, Yasunori
    Toyoshima, Takeshi
    BMC ORAL HEALTH, 2022, 22 (01)
  • [37] The effects of implant design, bone quality, and insertion process on primary stability of dental implants: An in-vitro study
    Rismanchian M.
    Afshari M.
    Afshari, Mojtaba (Afshari.m1989@gmail.com), 1600, Inderscience Publishers (34): : 319 - 333
  • [38] Primary stability and healing outcomes of apically tapered and straight implants placed into fresh extraction sockets. A pre-clinical in vivo study
    Ellis, Rebecca
    Chen, Stephen
    Davies, Helen
    Fitzgerald, Wayne
    Xu, Junhua
    Darby, Ivan
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (08) : 705 - 714
  • [39] Effect of a Modified Stepped Osteotomy on the Primary Stability of Dental Implants in Low-Density Bone: A Cadaver Study
    Boustany, Chad M.
    Reed, Hal
    Cunningham, Geoffrey
    Richards, Mark
    Kanawati, Ali
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (01) : 48 - 55
  • [40] Primary Stability/Mobility of 1-Stage and 2-Stage Dental Implants: A Comparative In Vitro Study
    Gulay, Gulsah
    Asar, Neset Volkan
    Tulunoglu, Ibrahim
    Turkyilmaz, Ilser
    Wang, Hom-Lay
    Tozum, Tolga F.
    IMPLANT DENTISTRY, 2012, 21 (06) : 461 - 466