Primary Stability/Mobility of 1-Stage and 2-Stage Dental Implants: A Comparative In Vitro Study

被引:4
|
作者
Gulay, Gulsah [2 ]
Asar, Neset Volkan [3 ]
Tulunoglu, Ibrahim [4 ]
Turkyilmaz, Ilser [5 ]
Wang, Hom-Lay [6 ]
Tozum, Tolga F. [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Periodontol, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[3] Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[4] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[5] Univ Texas Hlth Sci Ctr San Antonio, Dent Sch Implant Clin, Dept Comprehens Dent, San Antonio, TX 78229 USA
[6] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
关键词
dental implants; transducers; alveolar bone loss; stability; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; MANDIBULAR OVERDENTURES; INITIAL STABILITY; FOLLOW-UP; SYSTEMS; MULTICENTER; CAPACITY; DEFECTS;
D O I
10.1097/ID.0b013e3182661615
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the primary stability of 1-stage (nonsubmerged) and 2-stage (submerged) implants via newest wireless resonance frequency (RF) analyzer and newer wireless mobility measuring (MM) device. Materials and Methods: Six 1-stage dental implants with internal hex connection and six 2-stage dental implants, 4.1 mm in diameter and 11.5 mm in length, were inserted bilaterally into the first premolar, second premolar, and first molar regions of 6 standard mandibular transparent self-curing acrylic resin models. After that, the periimplant circular bone defects were created in millimeter increments ranging between 0 and 5 mm to the same extent on all implants. Results: Implant stability quotient values significantly decreased at 1-stage and 2-stage implants when periimplant defects increased. Similar implant stability quotient values were found for both implant types; however, significantly lower MM values were noted for 2-stage implants. Irrespective of implant systems, the results indicated a significant association between wireless RF analyzer and wireless MM device. Conclusion: Both wireless RF analyzer and wireless MM device were adequate in assessing implant stability. There was no difference between 2-stage and 1-stage implant systems, except lower MM values were noted for nonsubmerged implants. (Implant Dent 2012;21:461-466)
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [1] Retrospective cohort study of the clinical performance of 1-stage dental implants
    Carr, AB
    Choi, YG
    Eckert, SE
    Desjardins, RP
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 399 - 405
  • [2] COMPARISON OF 1-STAGE AND 2-STAGE NERVE GRAFTING OF THE RABBIT MEDIAN NERVE
    SHIBATA, M
    BREIDENBACH, WC
    OGDEN, L
    FIRRELL, J
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1991, 16A (02): : 262 - 268
  • [3] Bilateral Total Hip Arthroplasty: 1-Stage or 2-Stage? A Meta-Analysis
    Shao, Hongyi
    Chen, Chi-Lung
    Maltenfort, Mitchell G.
    Restrepo, Camilo
    Rothman, Richard H.
    Chen, Antonia F.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (02): : 689 - 695
  • [4] Comparison of 1-stage and 2-stage Managements for Common Bile Duct Stones and Gallstones (CBDS) A Retrospective Study
    Zhou, Jie
    Chen, Ye
    Yu, Songlin
    Wang, Hui
    Wang, Yufeng
    Chen, Quanning
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2025, 59 (03) : 269 - 275
  • [5] Outcomes After 1-Stage Versus 2-Stage Revision Anterior Cruciate Ligament Reconstruction
    Mitchell, Justin J.
    Chahla, Jorge
    Dean, Chase S.
    Cinque, Mark
    Matheny, Lauren M.
    LaPrade, Robert F.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2017, 45 (08): : 1790 - 1798
  • [6] Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis: A pilot study
    Zix, J
    Kessler-Liechti, G
    Mericske-Stern, D
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (05) : 747 - 752
  • [7] Letter to the Editor on "Bilateral Total Hip Arthroplasty: 1-Stage or 2-Stage? A Meta-Analysis"
    Bonilla, Guillermo A.
    Muskus, Meilyn A.
    Gutierrez, Camilo
    Llinas, Adolfo M.
    JOURNAL OF ARTHROPLASTY, 2017, 32 (04): : 1404 - 1405
  • [8] COMPARISON OF 1-STAGE AND 2-STAGE SELECTION ON ADULT WEIGHT AND EGG NUMBER IN TRIBOLIUM-CASTANEUM
    CAMPO, JL
    DELAFUENTE, MB
    JOURNAL OF ANIMAL BREEDING AND GENETICS-ZEITSCHRIFT FUR TIERZUCHTUNG UND ZUCHTUNGSBIOLOGIE, 1991, 108 (01): : 17 - 22
  • [9] Is 2-Stage Septic Revision Worth the Money? A Cost-Utility Analysis of a 1-Stage Versus 2-Stage Septic Revision of Total Knee Arthroplasty
    Okafor, Charles E.
    Nghiem, Son
    Byrnes, Joshua
    JOURNAL OF ARTHROPLASTY, 2023, 38 (02): : 347 - 354
  • [10] Stability measurements of 1-stage implants in the edentulous mandible by means of resonance frequency analysis
    Kessler-Liechti, Gerda
    Zix, Juergen
    Mericske-Stern, Regina
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (02) : 353 - 358