Primary Stability/Mobility of 1-Stage and 2-Stage Dental Implants: A Comparative In Vitro Study

被引:4
|
作者
Gulay, Gulsah [2 ]
Asar, Neset Volkan [3 ]
Tulunoglu, Ibrahim [4 ]
Turkyilmaz, Ilser [5 ]
Wang, Hom-Lay [6 ]
Tozum, Tolga F. [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Periodontol, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[3] Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[4] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[5] Univ Texas Hlth Sci Ctr San Antonio, Dent Sch Implant Clin, Dept Comprehens Dent, San Antonio, TX 78229 USA
[6] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
关键词
dental implants; transducers; alveolar bone loss; stability; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; MANDIBULAR OVERDENTURES; INITIAL STABILITY; FOLLOW-UP; SYSTEMS; MULTICENTER; CAPACITY; DEFECTS;
D O I
10.1097/ID.0b013e3182661615
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the primary stability of 1-stage (nonsubmerged) and 2-stage (submerged) implants via newest wireless resonance frequency (RF) analyzer and newer wireless mobility measuring (MM) device. Materials and Methods: Six 1-stage dental implants with internal hex connection and six 2-stage dental implants, 4.1 mm in diameter and 11.5 mm in length, were inserted bilaterally into the first premolar, second premolar, and first molar regions of 6 standard mandibular transparent self-curing acrylic resin models. After that, the periimplant circular bone defects were created in millimeter increments ranging between 0 and 5 mm to the same extent on all implants. Results: Implant stability quotient values significantly decreased at 1-stage and 2-stage implants when periimplant defects increased. Similar implant stability quotient values were found for both implant types; however, significantly lower MM values were noted for 2-stage implants. Irrespective of implant systems, the results indicated a significant association between wireless RF analyzer and wireless MM device. Conclusion: Both wireless RF analyzer and wireless MM device were adequate in assessing implant stability. There was no difference between 2-stage and 1-stage implant systems, except lower MM values were noted for nonsubmerged implants. (Implant Dent 2012;21:461-466)
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [21] The "Long Snodgrass": Applying the tubularized incised plate urethroplasty to penoscrotal hypospadias in 1-stage or 2-stage repairs - Discussion
    Snodgrass, W
    Palmer, L
    Snyder, H
    JOURNAL OF UROLOGY, 2002, 168 (04): : 1750 - 1750
  • [22] A comparison of labial and crestal incisions for the 1-stage placement of IMZ implants: A pilot study
    Heydenrijk, K
    Raghoebar, GM
    Batenburg, RHK
    Stegenga, B
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 58 (10) : 1119 - 1123
  • [23] Analysis of Short Implants and Lateralization of the Inferior Alveolar Nerve With 2-Stage Dental Implants by Finite Element Method
    Amorim Vasco, Marco Antonio
    Hecke, Mildred Ballin
    Bezzon, Osvaldo Luiz
    JOURNAL OF CRANIOFACIAL SURGERY, 2011, 22 (06) : 2064 - 2071
  • [24] Comparing Plastic Surgeon Operative Time for DIEP Flap Breast Reconstruction: 2-stage More Efficient than 1-stage?
    Issa, Christopher J.
    Lu, Stephen M.
    Boudiab, Elizabeth M.
    DeSano, Jeffrey
    Sachanandani, Neil S.
    Powers, Jeremy M.
    Chaiyasate, Kongkrit
    PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN, 2021, 9 (06) : E3608
  • [25] Comparison of safety between 1-stage and 2-stage surgery: from laparoscopic adjustable gastric banding to laparoscopic sleeve gastrectomy
    Lewis, Cameron S.
    Varmaa, Aditya K.
    Hamdorf, Jeffrey M.
    SURGERY FOR OBESITY AND RELATED DISEASES, 2016, 12 (05) : 976 - 983
  • [26] Microleakage into and from Two-Stage Implants: An In Vitro Comparative Study
    Teixeira, Wendel
    Ribeiro, Ricardo Faria
    Sato, Sandra
    Pedrazzi, Vinicius
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (01) : 56 - 62
  • [27] Clinical and radiologic evaluation of 2-stage IMZ implants placed in a single-stage procedure: 2-year results of a prospective comparative study
    Heydenrijk, K
    Raghoebar, GM
    Meijer, HJA
    Stegenga, B
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2003, 18 (03) : 424 - 432
  • [28] A comparison of labial and crestal incisions for the 1-stage placement of IMZ implants: A pilot study - Discussion
    Tarnow, DP
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 58 (10) : 1123 - 1124
  • [29] 2-STAGE TRANSFER OF GLYCINE BY INTESTINE IN VITRO
    NEWEY, H
    SMYTH, DH
    JOURNAL OF PHYSIOLOGY-LONDON, 1961, 157 (01): : P15 - &
  • [30] Real time spectroscopic ellipsometry studies of ultrathin CIGS films deposited by 1-stage, 2-stage and 3-stage co-evaporation processes
    Aryal, Krishna
    Rajan, Grace
    Ashrafee, Tasnuva
    Ranjan, Vikash
    Arya, Puruswottam
    Rockett, Angus
    Collins, Robert W.
    Marsillac, Sylvain
    2014 IEEE 40TH PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2014, : 323 - 327