Primary Stability/Mobility of 1-Stage and 2-Stage Dental Implants: A Comparative In Vitro Study

被引:4
|
作者
Gulay, Gulsah [2 ]
Asar, Neset Volkan [3 ]
Tulunoglu, Ibrahim [4 ]
Turkyilmaz, Ilser [5 ]
Wang, Hom-Lay [6 ]
Tozum, Tolga F. [1 ]
机构
[1] Hacettepe Univ, Fac Dent, Dept Periodontol, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[3] Gazi Univ, Fac Dent, Dept Prosthodont, Ankara, Turkey
[4] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
[5] Univ Texas Hlth Sci Ctr San Antonio, Dent Sch Implant Clin, Dept Comprehens Dent, San Antonio, TX 78229 USA
[6] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
关键词
dental implants; transducers; alveolar bone loss; stability; RESONANCE FREQUENCY-ANALYSIS; INSERTION TORQUE; MANDIBULAR OVERDENTURES; INITIAL STABILITY; FOLLOW-UP; SYSTEMS; MULTICENTER; CAPACITY; DEFECTS;
D O I
10.1097/ID.0b013e3182661615
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the primary stability of 1-stage (nonsubmerged) and 2-stage (submerged) implants via newest wireless resonance frequency (RF) analyzer and newer wireless mobility measuring (MM) device. Materials and Methods: Six 1-stage dental implants with internal hex connection and six 2-stage dental implants, 4.1 mm in diameter and 11.5 mm in length, were inserted bilaterally into the first premolar, second premolar, and first molar regions of 6 standard mandibular transparent self-curing acrylic resin models. After that, the periimplant circular bone defects were created in millimeter increments ranging between 0 and 5 mm to the same extent on all implants. Results: Implant stability quotient values significantly decreased at 1-stage and 2-stage implants when periimplant defects increased. Similar implant stability quotient values were found for both implant types; however, significantly lower MM values were noted for 2-stage implants. Irrespective of implant systems, the results indicated a significant association between wireless RF analyzer and wireless MM device. Conclusion: Both wireless RF analyzer and wireless MM device were adequate in assessing implant stability. There was no difference between 2-stage and 1-stage implant systems, except lower MM values were noted for nonsubmerged implants. (Implant Dent 2012;21:461-466)
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [41] THE 1ST STAGE IN 2-STAGE TEMPLATE MATCHING
    LI, XB
    DUBES, RC
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1985, 7 (06) : 700 - 707
  • [42] Comparison of 1-stage With 2-stage Multiple-tracts Mini-percutaneous Nephrolithotomy for the Treatment of Staghorn Stones: A Matched Cohorts Analysis
    Zhao, Zhijian
    Cui, Zenlin
    Zeng, Tao
    Wan, Shaw P.
    Zeng, Guohua
    UROLOGY, 2016, 87 : 46 - 51
  • [43] FUNCTIONAL AND IMMUNOLOGICAL ASSAYS OF FVIII IN 133 HEMOPHILIACS - CHARACTERIZATION OF A SUBGROUP OF PATIENTS WITH MILD HEMOPHILIA-A AND DISCREPANCY IN 1-STAGE AND 2-STAGE ASSAYS
    PARQUETGERNEZ, A
    MAZURIER, C
    GOUDEMAND, M
    THROMBOSIS AND HAEMOSTASIS, 1988, 59 (02) : 202 - 206
  • [44] THEORETICAL STUDY OF 2-STAGE TESTING
    LORD, FM
    PSYCHOMETRIKA, 1971, 36 (03) : 227 - &
  • [45] 2 1-STAGE IMPRESSION TECHNIQUES FOR FIXED PROSTHESES
    CRANIN, AN
    CRANIN, SL
    CICCARIELLO, AN
    JOURNAL OF PROSTHETIC DENTISTRY, 1965, 15 (03): : 484 - +
  • [46] BACTERIAL-COLONIZATION OF THE INTERNAL PART OF 2-STAGE IMPLANTS - AN IN-VIVO STUDY
    QUIRYNEN, M
    VANSTEENBERGHE, D
    CLINICAL ORAL IMPLANTS RESEARCH, 1993, 4 (03) : 158 - 161
  • [47] 1-stage versus 2-stage lateral sinus lift procedures: 1-year post-loading results of a multicentre randomised controlled trial
    Felice, Pietro
    Pistilli, Roberto
    Piattelli, Maurizio
    Soardi, Elisa
    Barausse, Carlo
    Corvino, Valeria
    Esposito, Marco
    EUROPEAN JOURNAL OF ORAL IMPLANTOLOGY, 2014, 7 (01) : 65 - 75
  • [48] Different underlying causes for the discrepancy between FVIII:C 1-stage and 2-stage results in type 2N vWD and variant mild haemophilia A
    Duncan, EM
    Rodgers, SE
    Lerda, N
    Casey, G
    Quinn, D
    Flower, R
    Rowell, J
    Baker, R
    Lloyd, JV
    THROMBOSIS AND HAEMOSTASIS, 1999, : 90 - 90
  • [49] COMPARATIVE-STUDY OF HODGSON-I AND KING METHODS OF 1-STAGE HYPOSPADIAS REPAIR
    KASRAEIAN, A
    RUSHDI, AM
    JOURNAL OF UROLOGY, 1985, 134 (05): : 918 - 918
  • [50] A retrospective study of implants placed following 1-stage or 2-stage maxillary sinus floor augmentation by the lateral window technique performed on residual bone of <4 mm: Results up to 10 years of follow-up
    Kim, Hyun Ju
    Yea, Sanghyun
    Kim, Kyoung-Hwa
    Lee, Yong-Moo
    Ku, Young
    Rhyu, In-Chul
    Seol, Yang-Jo
    JOURNAL OF PERIODONTOLOGY, 2020, 91 (02) : 183 - 193