Acoustic noise reduction in a 4 T MRI scanner

被引:45
|
作者
Mechefske, CK
Geris, R
Gati, JS
Rutt, BK
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
[2] Queens Univ, Dept Mech Engn, Kingston, ON K7L 3N6, Canada
关键词
acoustic noise reduction; echo planar imaging; magnetic resonance imaging; high field;
D O I
10.1016/S1352-8661(01)00146-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High-field, high-speed magnetic resonance imaging (MRI) can generate high levels of noise. There is ongoing concern in the medical and imaging research communities regarding the detrimental effects of high acoustic levels on auditory function, patient anxiety, verbal communication between patients and health care workers and ultimately MR image quality. In order to effectively suppress the noise levels inside MRI scanners, the sound field needs to be accurately measured and characterized. This paper presents the results of measurements of the sound radiation from a gradient coil cylinder within a 4 T MRI scanner under a variety of conditions, These measurement results show: (1) that noise levels can be significantly reduced through the use of an appropriately designed passive acoustic liner; and (2) the true noise levels that are experienced by patients during echo planar imaging. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:172 / 176
页数:5
相关论文
共 50 条
  • [21] A Structure Design Method for Reduction of MRI Acoustic Noise
    Nan, Jiaofen
    Zong, Nannan
    Chen, Qiqiang
    Zhang, Liangliang
    Zheng, Qian
    Xia, Yongquan
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2017, 2017
  • [22] Acoustic Noise Reduction of Echo Planar Imaging in Diffusion MRI
    Zhao, Junwei
    Lin, Zhenliang
    Zhou, Xiaodong
    Li, Guobin
    Luo, Jie
    ICBBE 2019: 2019 6TH INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOINFORMATICS ENGINEERING, 2019, : 33 - 38
  • [23] MRI acoustic noise
    Sellers, MB
    Pavlidis, JD
    Carlberger, T
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1996, 2 (06): : 549 - 560
  • [24] Modal analysis and acoustic noise characterization of a 4T MRI gradient coil insert
    Mechefske, CK
    Yao, G
    Li, W
    Gazdzinski, C
    Rutt, BK
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2004, 22B (01) : 37 - 49
  • [25] Acoustic noise reduction in MRI using Silent Scan: an initial experience
    Alibek, Sedat
    Vogel, Mika
    Sun, Wei
    Winkler, David
    Baker, Christopher A.
    Burke, Michael
    Gloger, Hubertus
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2014, 20 (04) : 360 - 363
  • [26] Reduction of gradient acoustic noise in MRI using SENSE-EPI
    de Zwart, JA
    van Gelderen, P
    Kellman, P
    Duyn, JH
    NEUROIMAGE, 2002, 16 (04) : 1151 - 1155
  • [27] Active-passive gradient shielding for MRI acoustic noise reduction
    Edelstein, WA
    Kidane, TK
    Taracila, V
    Baig, TN
    Eagan, TP
    Cheng, YCN
    Brown, RW
    Mallick, JA
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) : 1013 - 1017
  • [28] Sequence-Based Acoustic Noise Reduction of Clinical MRI Scans
    Heismann, Bjoern
    Ott, Martin
    Grodzki, David
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 1104 - 1109
  • [29] Acoustic noise levels and field distribution in 7 T MRI scanners
    Shtrepi, Louena
    Poggetto, Vinicius F. Dal
    Durochat, Clement
    Dubois, Marc
    Bendahan, David
    Nistri, Fabio
    Miniaci, Marco
    Pugno, Nicola Maria
    Bosia, Federico
    FRONTIERS IN PHYSICS, 2023, 11
  • [30] Spatial analysis of acoustic noise transfer function with a human-body phantom in a clinical MRI scanner
    Hamaguchi, Takashi
    Miyati, Tosiaki
    Ohno, Naoki
    Matsushita, Tatsuhiko
    Takata, Tadanori
    Matsuura, Yukihiro
    Kobayashi, Satoshi
    Gabata, Toshifumi
    ACTA RADIOLOGICA, 2023, 64 (03) : 1212 - 1221