Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction

被引:52
|
作者
Schramm, Georg [1 ]
Langner, Jens [1 ]
Hofheinz, Frank [1 ]
Petr, Jan [1 ]
Beuthien-Baumann, Bettina [2 ]
Platzek, Ivan [3 ]
Steinbach, Joerg [1 ]
Kotzerke, Joerg [2 ]
van den Hoff, Joerg [1 ,2 ]
机构
[1] Helmholtz Zentrum Dresden Rossendorf, PET Ctr, Inst Radiopharm, Dresden, Germany
[2] Tech Univ Dresden, Dept Nucl Med, Univ Hosp Carl Gustav Carus, D-01062 Dresden, Germany
[3] Tech Univ Dresden, Dept Radiol, Univ Hosp Carl Gustav Carus, D-01062 Dresden, Germany
关键词
PET/MR; MR-based attenuation correction; PET quantification; PERFORMANCE EVALUATION; NEXT-GENERATION; MRI; IMAGES; CT;
D O I
10.1007/s10334-012-0328-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Evaluation of the quantitative accuracy of MR-based attenuation correction (MRAC) in the Philips Ingenuity TF whole-body PET/MR. In 13 patients, PET emission data from the PET/MR were reconstructed using two different methods for attenuation correction. In the first reconstruction, the vendor-provided standard MRAC was used. In the second reconstruction, a coregistered transmission-based attenuation map from a second immediately preceding investigation with a stand-alone Siemens ECAT EXACT HR+ PET scanner was used (TRAC). The two attenuation maps were compared regarding occurrence of segmentation artifacts in the MRAC procedure. Standard uptake values (SUVs) of multiple VOIs (liver, cerebellum, hot focal structures at various locations in the trunk) were compared between both reconstructed data sets. Furthermore, a voxel-wise intensity correlation analysis of both data sets in the lung and trunk was performed. VOI averaged SUV differences between MRAC and TRAC were as follows (relative differences, mean +/- A standard deviation): (+12 +/- A 6) % cerebellum, (-4 +/- A 9) % liver, (-2 +/- A 11) % hot focal structures. The fitted slopes of the voxel-wise correlations in the lung and trunk were 0.87 +/- A 0.17 and 0.95 +/- A 0.10 with averaged adjusted R (2) values of 0.96 and 0.98, respectively. These figures include two instances with partially erroneous lung segmentation due to artifacts in the underlying MR images. The MR-based attenuation correction implemented on the Philips Ingenuity PET/MR provides reasonable quantitative accuracy. On average, deviations from TRAC-based results are small (on the order of 10 % or below) across the trunk, but due to interindividual variability of the segmentation quality, deviations of more than 20 % can occur. Future improvement of the segmentation quality would help to increase the quantitation accuracy further and to reduce the inter-subject variability.
引用
收藏
页码:115 / 126
页数:12
相关论文
共 50 条
  • [1] Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction
    Schramm, Georg
    Langner, Jens
    Hofheinz, Frank
    Petr, Jan
    Beuthien-Baumann, Bettina
    Platzek, Ivan
    Steinbach, Joerg
    Kotzerke, Joerg
    van den Hoff, Joerg
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2015, 28 (01) : 101 - 101
  • [2] Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction
    Georg Schramm
    Jens Langner
    Frank Hofheinz
    Jan Petr
    Bettina Beuthien-Baumann
    Ivan Platzek
    Jörg Steinbach
    Jörg Kotzerke
    Jörg van den Hoff
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2013, 26 : 115 - 126
  • [3] Erratum to: Quantitative accuracy of attenuation correction in the Philips Ingenuity TF whole-body PET/MR system: a direct comparison with transmission-based attenuation correction
    Georg Schramm
    Jens Langner
    Frank Hofheinz
    Jan Petr
    Bettina Beuthien-Baumann
    Ivan Platzek
    Jörg Steinbach
    Jörg Kotzerke
    Jörg van den Hoff
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2015, 28 : 101 - 101
  • [4] Quantitative accuracy of MR-based attenuation correction in whole-body PET/MR
    Schramm, Georg
    Langner, Jens
    Hofheinz, Frank
    Baumann, Bettina Beuthien
    Platzek, Ivan
    Kotzerke, Jorg
    Steinbach, Joerg
    van den Hoff, Joerg
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [5] MR-based Attenuation Correction for Whole-body PET/MR System
    Hu, Z.
    Renisch, S.
    Schweizer, B.
    Blaffert, T.
    Ojha, N.
    Guo, T.
    Tang, J.
    Tung, C.
    Kaste, J.
    Schulz, V.
    Torres, I.
    Shao, L.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2119 - 2122
  • [6] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    David Izquierdo-Garcia
    Stephen J. Sawiak
    Karin Knesaurek
    Jagat Narula
    Valentin Fuster
    Joseph Machac
    Zahi A. Fayad
    European Journal of Nuclear Medicine and Molecular Imaging, 2014, 41 : 1574 - 1584
  • [7] Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging
    Izquierdo-Garcia, David
    Sawiak, Stephen J.
    Knesaurek, Karin
    Narula, Jagat
    Fuster, Valentin
    Machac, Joseph
    Fayad, Zahi A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 (08) : 1574 - 1584
  • [8] MR-based Attenuation Correction for a Whole-body Sequential PET/MR System
    Hu, Z.
    Ojha, N.
    Renisch, S.
    Schulz, V.
    Torres, I.
    Buhl, A.
    Pal, D.
    Muswick, G.
    Penatzer, J.
    Guo, T.
    Boenert, P.
    Tung, C.
    Kaste, J.
    Morich, M.
    Havens, T.
    Maniawski, P.
    Schaefer, W.
    Guenther, R. W.
    Krombach, G. A.
    Shao, L.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3508 - 3512
  • [9] A determination of the minimum necessary accuracy of MR attenuation correction for quantitative whole-body PET/MR imaging
    Ai, Hua
    Mawlawi, Osama
    Stafford, Jason
    Bankson, Jim
    Shao, Yiping
    Guindani, Michele
    Wendt, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57
  • [10] MR-based attenuation correction for whole-body PET-MR
    Ouyang, Jinsong
    Chun, Se Young
    Brady, Thomas
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51