Beam characteristics of the first clinical 360° rotational single gantry room scanning pencil beam proton treatment system and comparisons against a multi-room system

被引:5
|
作者
Shang, Charles [1 ]
Evans, Grant [1 ]
Rahman, Mushfiqur [1 ]
Lin, Liyong [2 ]
机构
[1] South Florida Proton Therapy Inst, Delray Beach, FL 33484 USA
[2] Emory Proton Therapy Ctr, Atlanta, GA USA
来源
关键词
commissioning; pencil beam scanning; protons; treatment planning system; DOSE CALCULATION; ALGORITHM;
D O I
10.1002/acm2.12984
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purpose of this study was to present the proton beam characteristics of the first clinical single-room ProBeam Compact (TM) proton therapy system (SRPT) and comparison against multi-room ProBeam (TM) system (MRPT). Materials and Methods A newly designed SRPT with proton beam energies ranging from 70 to 220 MeV was commissioned in late 2019. Integrated depth doses (IDDs) were scanned using 81.6 mm diameter Bragg peak chambers and normalized by outputs at 15 mm WET and 1.1 RBE offset, following the methodology of TRS 398. The in-air beam spot profiles were acquired by a planar scintillation device, respectively, at ISO, upper and down streams, fitted with single Gaussian distribution for beam modeling in Eclipse v15.6. The field size effect was adjusted for the best overall accuracy of clinically relevant field QAs. The halo effects at near surface were quantified by a pinpoint ionization chamber. Its major dosimetric characteristics were compared against MRPT comparable beam dataset. Results Contrast to MRPT, an increased proton straggling in the Bragg peak region was found with widened beam distal falloffs and elevated proximal transmission dose values. Integrated depth doses showed 0.105-0.221 MeV (energy sigma) or 0.30-0.94 mm broader Bragg peak widths (R-b80-R-a80) for 130 MeV or higher energy beams and up to 0.48-0.79 mm extended distal falloffs (R-b20-R-b80). Minor differences were identified in beam spot sizes, spot divergences, proton particles/MU, and field size output effects. High passing scores are reported for independent end-to-end dosimetry checks by IROC and for initial 108 field-specific QAs at 3%/3 mm Gamma index with fields regardless with or without range shifters. Conclusions The author highlighted the dosimetry differences in IDDs mainly caused by the shortened beam transport system of SRPT, for which new acceptance criteria were adapted. This report offers a unique reference for future commissioning, beam modeling, planning, and analysis of QA and clinical studies.
引用
收藏
页码:266 / 271
页数:6
相关论文
共 50 条
  • [31] A benchmarking method to evaluate the accuracy of a commercial proton monte carlo pencil beam scanning treatment planning system
    Lin, Liyong
    Huang, Sheng
    Kang, Minglei
    Hiltunen, Petri
    Vanderstraeten, Reynald
    Lindberg, Jari
    Siljamaki, Sami
    Wareing, Todd
    Davis, Ian
    Barnett, Allen
    McGhee, John
    Simone, Charles B., II
    Solberg, Timothy D.
    McDonough, James E.
    Ainsley, Christopher
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (02): : 44 - 49
  • [32] Feasibility study of a plastic scintillating plate-based treatment beam fluence monitoring system for use in pencil beam scanning proton therapy
    Jeong, Seonghoon
    Chung, Kwangzoo
    Ahn, Sung Hwan
    Lee, Boram
    Seo, Jaehyeon
    Yoon, Myonggeun
    MEDICAL PHYSICS, 2020, 47 (02) : 703 - 712
  • [33] Clinical commissioning of a therapeutic uniform proton beam scanning system with multi-element detectors
    Farr, J.
    Mascia, A.
    Hsi, W.
    Allgower, C.
    Jesseph, F.
    Nichiporov, D.
    Anferov, V.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 127 - 127
  • [34] Investigation of the impact of machine operating parameters on beam delivery time and its correlation with treatment plan characteristics for synchrotron-based proton pencil beam spot scanning system
    Liang, Xiaoying
    Beltran, Chris
    Liu, Chunbo
    Shen, Jiajian
    Bues, Martin
    Furutani, Keith M. M.
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [35] Evaluation of monte carlo to support commissioning of the treatment planning system of new pencil beam scanning proton therapy facilities
    Botnariuc, D.
    Court, S.
    Lourenco, A.
    Gosling, A.
    Royle, G.
    Hussein, M.
    Rompokos, V
    Veiga, C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (04):
  • [36] Feasibility of Pencil Beam Scanning Proton Therapy Treatment Planning with a Dynamic Collimation System in an FDA-Cleared TPS
    Bennett, L.
    Smith, B.
    Flynn, R.
    Hyer, D.
    Wang, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E101 - E101
  • [37] Clinical validation of a GPU-based Monte Carlo dose engine of a commercial treatment planning system for pencil beam scanning proton therapy
    Fracchiolla, Francesco
    Engwall, Erik
    Janson, Martin
    Tamm, Fredrik
    Lorentini, Stefano
    Fellin, Francesco
    Bertolini, Mattia
    Algranati, Carlo
    Righetto, Roberto
    Farace, Paolo
    Amichetti, Maurizio
    Schwarz, Marco
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 88 : 226 - 234
  • [38] Prospective study to evaluate the safety of the world-first spot-scanning dedicated, small 360-degree gantry, synchrotron-based proton beam therapy system
    Nishioka, Kentaro
    Prayongrat, Anussara
    Ono, Kota
    Onodera, Shunsuke
    Hashimoto, Takayuki
    Katoh, Norio
    Inoue, Tetsuya
    Kinoshita, Rumiko
    Yasuda, Koichi
    Mori, Takashi
    Onimaru, Rikiya
    Shirato, Hiroki
    Shimizu, Shinichi
    JOURNAL OF RADIATION RESEARCH, 2018, 59 : I63 - I71
  • [39] Experimental Validation and Calculation Benchmark for a Commercial Monte Carlo Pencil Beam Scanning Proton Therapy Treatment Planning System in Water
    Lin, L.
    Huang, S.
    Kang, M.
    Ainsley, C.
    Hiltunen, P.
    Vanderstraeten, R.
    Lindberg, J.
    Siljamaki, S.
    Wareing, T.
    Davis, I.
    Barnett, A.
    McGhee, J.
    Solberg, T.
    McDonough, J.
    Simone, C., II
    MEDICAL PHYSICS, 2016, 43 (06) : 3497 - 3497
  • [40] Development of a Daily-Treatment Beam-Monitoring System Based Gafchromic EBT3 Film for Pencil-Beam Scanning Proton Therapy
    Jeong, Seonghoon
    Yoon, Myonggeun
    Chung, Kwangzoo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 76 (08) : 769 - 773