Electron dosimetry based on the absorbed dose to water concept:: A comparison of the AAPM TG-51 and DIN 6800-2 protocols

被引:10
|
作者
Dohm, OS
Christ, G
Nüsslin, F
Schüle, E
Bruggmoser, G
机构
[1] Univ Tubingen, Klin Radioonkol, Abt Med Phys, D-72076 Tubingen, Germany
[2] PTW Freiburg, D-79115 Freiburg, Germany
[3] Univ Freiburg Klinikum, Abt Strahlentherapie, D-79106 Freiburg, Germany
关键词
electron dosimetry; absorbed dose to water; Roos chamber; perturbation correction;
D O I
10.1118/1.1414008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dosimetry protocols DIN 6800-2 and AAPM TG-51, both based on the absorbed dose to water concept, are compared in their theoretical background and in their application to electron dosimetry. The agreement and disagreement in correction factors and energy parameters used in both protocols will be shown and discussed. Measurements with three different types of ionization chambers were performed and evaluated according to both protocols. As a result the perturbation correction factor P-wall(60Co) for the Roos chamber was determined to 1.024 +/- 0.5%. (C) 2001 American Association of Physicists in Medicine.
引用
收藏
页码:2258 / 2264
页数:7
相关论文
共 37 条
  • [21] Comparison of AAPM Addendum to TG-51, IAEA TRS-398, and JS']JSMP 12: Calibration of photon beams in water
    Kinoshita, Naoki
    Oguchi, Hiroshi
    Nishimoto, Yasuhiro
    Adachi, Toshiki
    Shioura, Hiroki
    Kimura, Hirohiko
    Doi, Kunio
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 271 - 278
  • [22] Technical note: Consistency of IAEA's TRS-483 and AAPM's extended TG-51 protocols for clinical reference dosimetry of the CyberKnife M6 machine
    Duchaine, Jasmine
    Markel, Daniel
    Ley, Jean-Luc
    Beliveau-Nadeau, Dominique
    Zerouali, Karim
    Doucet, Robert
    Bouchard, Hugo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (05):
  • [23] Detector Based Determination of Water Absorbed Dose According to DIN 6800 Part 1: Suggestion for an Extension of the Fundamental Formalism
    Hartmann, Guether H.
    Hensley, Frank
    Kapsch, Ralf-Peter
    Poppe, Bjoern
    Sauer, Otto
    Wuerfel, Jan
    Zink, Klemens
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2020, 30 (01): : 24 - 39
  • [24] Comparison of derived correction factors for effects of ion recombination and photon beam quality index following TG-51 and TRS-398 dosimetry protocols
    Bojdani, Seyed Mehdi Hosseini
    Baghani, Hamid Reza
    Robatjazi, Mostafa
    Andreoli, Stefano
    Azadegan, Behnam
    APPLIED RADIATION AND ISOTOPES, 2023, 197
  • [25] A dosimetry study comparing NCS report-5, IAEA TRS-381, AAPM TG-51 and IAEA TRS-398 in three clinical electron beam energies
    Palmans, H
    Nafaa, L
    de Patoul, N
    Denis, JM
    Tomsej, M
    Vynckier, S
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (09): : 1091 - 1107
  • [26] Comparison of the IAEA TRS 398 Code of Practice and the AAPM TG51 Protocol for Dosimetry Calibration of high energy photon and electron beams
    Landoni, V
    Malatesta, T
    Capparella, R
    Fragomeni, R
    Proietti, A
    Begnozzi, L
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2003, 19 (01): : 31 - 35
  • [27] A dosimetric evaluation of the IAEA-AAPM TRS483 code of practice for dosimetry of small static fields used in conventional linac beams and comparison with IAEA TRS-398, AAPM TG51, and TG51 Addendum protocols
    Huq, M. Saiful
    Hwang, Min-Sig
    Teo, Troy P.
    Jang, Si Young
    Heron, Dwight E.
    Lalonde, Ronald J.
    MEDICAL PHYSICS, 2018, 45 (09) : 4257 - 4273
  • [28] A COMPARISON OF THE AAPM PROTOCOL FOR THE DETERMINATION OF ABSORBED DOSE FROM HIGH-ENERGY PHOTON AND ELECTRON-BEAMS WITH CURRENTLY USED PROTOCOLS
    HUNT, MA
    MALIK, S
    THOMASON, C
    MASTERSON, ME
    MEDICAL PHYSICS, 1984, 11 (06) : 806 - 813
  • [29] Comment on "AAPM's TG-51 protocol for clinical reference dosimetry of high-energy photon and electron beams" [Med. Phys. 26, 1847-1870 (1999)]
    Khan, FM
    MEDICAL PHYSICS, 2000, 27 (03) : 445 - 447
  • [30] Clinical Dosimetry of Photon Sources Used in Brachytherapy: Need for ISO Standardization, Based on and Extending the AAPM TG-43U1 Formalism by Calibration in Terms of Absorbed Dose to Water
    Quast, U.
    Kaulich, T.
    Ahnesjo, A.
    Alvarez-Romero, J.
    Donnarieix, D.
    Hensley, F.
    Maigne, L.
    Medich, D.
    Mourtada, F.
    Pradhan, A.
    Zakaria, G.
    MEDICAL PHYSICS, 2010, 37 (06)