Biomechanical Loading Comparison between Titanium and Bioactive Resorbable Screw Systems for Fixation of Intracapsular Condylar Head Fractures

被引:7
|
作者
Sukegawa, Shintaro [1 ,2 ]
Yamamoto, Norio [2 ]
Nakano, Keisuke [3 ]
Takabatake, Kiyofumi [3 ]
Kawai, Hotaka [3 ]
Kanno, Takahiro [4 ]
Nagatsuka, Hitoshi [3 ]
Furuki, Yoshihiko [1 ]
机构
[1] Kagawa Prefectural Cent Hosp, Dept Oral & Maxillofacial Surg, 1-2-1 Asahi Machi, Takamatsu, Kagawa 7608557, Japan
[2] Kagawa Prefectural Cent Hosp, Dept Orthopaed Surg, Takamatsu, Kagawa 600065, Japan
[3] Okayama Univ, Dept Oral Pathol & Med, Grad Sch Med Dent & Pharmaceut Sci, Okayama 7008530, Japan
[4] Shimane Univ, Dept Oral & Maxillofacial Surg, Fac Med, Matsue, Shimane 6930021, Japan
关键词
titanium screw; bioactive resorbable screw; biomechanical loading evaluation; fracture fixation; intracapsular condylar head fracture; POLY-L-LACTIDE; HYDROXYAPATITE HA PARTICLES; INTERNAL-FIXATION; FORGED COMPOSITES; BIORESORBABLE DEVICES; MANDIBULAR CONDYLE; SURGICAL-TREATMENT; OPEN REDUCTION; OSTEOSYNTHESIS; PLATE;
D O I
10.3390/ma13143153
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Osteosynthesis resorbable materials made of uncalcined and unsintered hydroxyapatite (u-HA) particles, poly-L-lactide (PLLA), are bioresorbable, and these materials have feasible bioactive/osteoconductive capacities. However, their strength and stability for fixation in mandibular condylar head fractures remain unclear. This in vitro study aimed to assess the biomechanical strength of u-HA/PLLA screws after the internal fixation of condylar head fractures. To evaluate their biomechanical behavior, 32 hemimandible replicas were divided into eight groups, each consisting of single-screw and double-screw fixations with titanium or u-HA/PLLA screws. A linear load was applied as vertical and horizontal load to each group to simulate the muscular forces in condylar head fractures. Samples were examined for 0.5, 1, 2, and 3-mm displacement loads. Two screws were needed for stable fixation of the mandibular condylar head fracture during biomechanical evaluation. After screw fixation for condylar head fractures, the titanium screws model was slightly more resistant to vertical and horizontal movement with a load for a small displacement than the u-HA/PLLA screws model. There was no statistically significant difference with load for large displacements. The u-HA/PLLA screw has a low mechanical resistance under small displacement loading compared with titanium within the limits of the mandibular head fracture model study.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A biomechanical comparison between cortical bone trajectory fixation and pedicle screw fixation
    Oshino, Hiroki
    Sakakibara, Toshihiko
    Inaba, Tadashi
    Yoshikawa, Takamasa
    Kato, Takaya
    Kasai, Yuichi
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [22] A biomechanical comparison between cortical bone trajectory fixation and pedicle screw fixation
    Hiroki Oshino
    Toshihiko Sakakibara
    Tadashi Inaba
    Takamasa Yoshikawa
    Takaya Kato
    Yuichi Kasai
    Journal of Orthopaedic Surgery and Research, 10
  • [23] Suture versus screw fixation of displaced tibial eminence fractures: A biomechanical comparison
    Bong, MR
    Romero, A
    Kubiak, E
    Iesaka, K
    Heywood, CS
    Kummer, F
    Rosen, J
    Jazrawi, L
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (10): : 1172 - 1176
  • [24] Biomechanical Comparison of Stability of Resorbable Plate-Screw Fixation Systems in Different Configurations After Sagittal Split Ramus Osteotomy
    Ulu, Murat
    Kelebek, Seyfi
    Dikici, Serkan
    Akcay, Huseyin
    Oflaz, Hakan
    2015 19TH NATIONAL BIOMEDICAL ENGINEERING MEETING (BIYOMUT), 2015,
  • [25] Comparison of Fixation Stability of Resorbable Versus Titanium Plate and Screws in Mandibular Angle Fractures
    Bayram, Burak
    Araz, Kenan
    Uckan, Sina
    Balcik, Cenk
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (08) : 1644 - 1648
  • [26] Aesthetic and Functional Outcome of Zygomatic Fractures Fixation Comparison With Resorbable Versus Titanium Plates
    Mahmoud, Shadad M.
    Liao, Han-Tsung
    Chen, Chien-Tzung
    ANNALS OF PLASTIC SURGERY, 2016, 76 : S85 - S90
  • [27] COMPARATIVE BIOMECHANICAL STABILITY OF TITANIUM BONE FIXATION SYSTEMS IN METACARPAL FRACTURES
    PREVEL, CD
    MCCARTY, M
    KATONA, T
    MOORE, K
    JACKSON, JR
    EPPLEY, BL
    SOOD, R
    ANNALS OF PLASTIC SURGERY, 1995, 35 (01) : 6 - 14
  • [28] Erratum to: A biomechanical comparison between cortical bone trajectory fixation and pedicle screw fixation
    Hiroki Oshino
    Toshihiko Sakakibara
    Tadashi Inaba
    Takamasa Yoshikawa
    Takaya Kato
    Yuichi Kasai
    Journal of Orthopaedic Surgery and Research, 10
  • [29] Fixation techniques for transverse acetabular fractures: Comparison of different biomechanical loading patterns
    Veeresh, Vivek
    Bansal, Hemant
    Mittal, Samarth
    Trikha, Vivek
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (06): : 2385 - 2385
  • [30] Comparison of stability of titanium and absorbable plate and screw fixation for mandibular angle fractures
    Esen, Alparslan
    Ataoglu, Hanife
    Gemi, Lokman
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2008, 106 (06): : 806 - 811