Dynamic contrast-enhanced 3D breath hold MRA using a multiple variable orientation slab aquisition

被引:0
|
作者
Shetty, AN [1 ]
Bis, KG [1 ]
机构
[1] William Beaumont Hosp, Dept Diagnost Radiol, Royal Oak, MI 48073 USA
关键词
vascular angiography; pulmonary MRA; renal MRA;
D O I
10.1016/S0730-725X(99)00003-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the conventional 3D MR angiographic sequences, it is difficult to prescribe multiple phases in different orientations, though multiple phases may be prescribed in the same orientation as the initial scan., Magnetic resonance angiography (MRA) was performed in which three slabs were prescribed in different orientations and were acquired in a sequential manner, A fixed delay of 8 s between the slabs was used to prepare patients to hold their breath for subsequent measurements. All subjects tolerated the entire breath hold examination. The results were easily reproducible and yielded high-resolution 3-dimensional images in various planes, (C) 1999 Elsevier Science Inc.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 50 条
  • [41] Accelerated Bilateral Dynamic Contrast-Enhanced 3D Spiral Breast MRI Using TSENSE
    Han, Misung
    Daniel, Bruce L.
    Hargreaves, Brian A.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (06) : 1425 - 1434
  • [42] Reconstruction of 3D Dynamic Contrast-Enhanced Magnetic Resonance Imaging Using Nonlocal Means
    Adluru, Ganesh
    Tasdizen, Tolga
    Schabel, Matthias C.
    DiBella, Edward V. R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (05) : 1217 - 1227
  • [43] Breath-hold 3D gadolinium-enhanced subtraction MRA in the detection of transplant renal artery stenosis
    Luk, SH
    Chan, JHM
    Kwan, TH
    Tsui, WC
    Cheung, YK
    Yuen, MK
    CLINICAL RADIOLOGY, 1999, 54 (10) : 651 - 654
  • [44] 3D Contrast-enhanced MR angiography
    Zhang, HongLei
    Maki, Jeffrey H.
    Prince, Martin R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 13 - 25
  • [45] Contrast-enhanced MRA and 3D visualization of pulmonary venous anatomy to assist radiofrequency catheter ablation
    Vonken, EPA
    Velthuis, BK
    Wittkampf, FH
    Rensing, BJ
    Derksen, R
    Cramer, MJM
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (04) : 545 - 551
  • [46] Bolus-chasing contrast-enhanced 3D MRA of the lower extremity -: Comparison with intraarterial DSA
    Steffens, JC
    Schäfer, FKW
    Oberscheid, B
    Link, J
    Jahnke, T
    Heller, M
    Brossmann, J
    ACTA RADIOLOGICA, 2003, 44 (02) : 185 - 192
  • [47] Contrast-enhanced 3D MRA of the aortoiliac and infrainguinal arteries when conventional transfemoral arteriography is not feasible
    Fenchel, S
    Wisianowsky, C
    Schams, S
    Nuessle, K
    Krämer, SC
    Görich, J
    Merkle, EM
    JOURNAL OF ENDOVASCULAR THERAPY, 2002, 9 (04) : 511 - 519
  • [48] Breath-hold electrocardiogram-triggered, contrast-enhanced, 3D MR angiography to evaluate patency of coronary artery bypass graft
    Vrachliotis, TG
    Aliabadi, D
    Bis, KG
    Shetty, AN
    London, J
    Farah, J
    RADIOLOGY, 1996, 201 : 784 - 784
  • [49] Contrast-enhanced breath-hold FISP 3D MR angiography to visualize the pulmonary artery tree and detect pulmonary artery occlusions
    Steffens, JC
    Link, J
    MuellerHuelsbeck, S
    Brinkmann, G
    Heller, M
    RADIOLOGY, 1996, 201 : 560 - 560
  • [50] Breath held high resolution 3D contrast-enhanced renal artery MR angiography
    Silverman, JM
    Tyszka, JM
    Sun, Y
    RADIOLOGY, 1997, 205 : 278 - 278