Dynamic contrast-enhanced 3D breath hold MRA using a multiple variable orientation slab aquisition

被引:0
|
作者
Shetty, AN [1 ]
Bis, KG [1 ]
机构
[1] William Beaumont Hosp, Dept Diagnost Radiol, Royal Oak, MI 48073 USA
关键词
vascular angiography; pulmonary MRA; renal MRA;
D O I
10.1016/S0730-725X(99)00003-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With the conventional 3D MR angiographic sequences, it is difficult to prescribe multiple phases in different orientations, though multiple phases may be prescribed in the same orientation as the initial scan., Magnetic resonance angiography (MRA) was performed in which three slabs were prescribed in different orientations and were acquired in a sequential manner, A fixed delay of 8 s between the slabs was used to prepare patients to hold their breath for subsequent measurements. All subjects tolerated the entire breath hold examination. The results were easily reproducible and yielded high-resolution 3-dimensional images in various planes, (C) 1999 Elsevier Science Inc.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 50 条
  • [11] CONTRAST-ENHANCED 3D BREATH-HOLD MR-ANGIOGRAPHY - APPLICATION IN ABDOMINAL AND ILIAC VESSELS
    SHETTY, AN
    SHIRKHODA, A
    BIS, KG
    RADIOLOGY, 1995, 197 : 516 - 517
  • [12] Different approaches for optimization of contrast-enhanced breath-hold 3D MR angiography of the abdominal vessels
    Kopka, L
    Rodenwaldt, J
    Vosshenrich, R
    Grabbe, EH
    RADIOLOGY, 1997, 205 : 273 - 273
  • [13] Improve temporal and spatial resolution in contrast-enhanced 3D MRA using paralle imaging
    Quijano, CV
    Chen, Q
    Li, W
    Storey, P
    Mai, VM
    Edelman, RT
    RADIOLOGY, 2002, 225 : 571 - 572
  • [14] Dynamic contrast-enhanced 3D photoacoustic imaging
    Wong, Philip
    Kosik, Ivan
    Carson, Jeffrey J. L.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013, 2013, 8581
  • [15] Combined Dynamic Contrast-Enhanced Liver MRI and MRA Using Interleaved Variable Density Sampling
    Rahimi, Mahdi Salmani
    Korosec, Frank R.
    Wang, Kang
    Holmes, James H.
    Motosugi, Utaroh
    Bannas, Peter
    Reeder, Scott B.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) : 973 - 983
  • [16] Fast arterial-venous communication, as demonstrated on dynamic contrast-enhanced 2D MRA, causes venous signal in bolus chase contrast-enhanced 3D MRA of the lower extremity
    Wang, Y
    Winchester, PA
    Khilnani, NM
    Trost, DW
    Watts, R
    Prince, MR
    RADIOLOGY, 2000, 217 : 237 - 237
  • [17] Breath-hold 3D MR angiography of the renal vasculature using a contrast-enhanced multiecho gradient-echo technique
    Papachristopoulos, G
    Bis, KG
    Shetty, AN
    Ross, M
    Bagga, H
    Shirkhoda, A
    Laub, G
    INVESTIGATIVE RADIOLOGY, 1999, 34 (12) : 731 - 738
  • [18] Comparative evaluation of TEE, conventional MRI and contrast-enhanced 3D breath-hold MRA in the post-operative follow-up of dissecting aneurysms
    Ernesto Di Cesare
    Aldo Victor Giordano
    Gabriella Cerone
    Francesco De Remigis
    Giuseppe D'Eusanio
    Carlo Masciocchi
    The International Journal of Cardiac Imaging, 2000, 16 : 135 - 147
  • [19] Comparative evaluation of TEE, conventional MR imaging and contrast-enhanced 3D breath hold MRA in the post-operative follow-up of dissecting aneurysms
    Di Cesare, EE
    Giordano, AA
    Cerone, GG
    De Remigis, FF
    Di Eusanio, GG
    Masciocchi, C
    RADIOLOGY, 1999, 213P : 137 - 137
  • [20] Comparative evaluation of TEE, conventional MRI and contrast-enhanced 3D breath-hold MRA in the post-operative follow-up of dissecting aneurysms
    Di Cesare, E
    Giordano, AV
    Cerone, G
    De Remigis, F
    D'Eusanio, G
    Masciocchi, C
    INTERNATIONAL JOURNAL OF CARDIAC IMAGING, 2000, 16 (03): : 135 - 147