Validation of a novel respiratory rate monitor based on exhaled humidity

被引:17
|
作者
Niesters, M. [1 ]
Mahajan, R. [2 ]
Olofsen, E. [1 ]
Boom, M. [1 ]
Garcia del Valle, S. [3 ]
Aarts, L. [1 ]
Dahan, A. [1 ]
机构
[1] Leiden Univ Med Ctr, Dept Anesthesiol, NL-2300 RC Leiden, Netherlands
[2] Univ Nottingham, Queens Med Ctr, Div Anaesthesia & Intens Care, Nottingham NG7 2UH, England
[3] Hosp Univ Fdn Alcorcon, Area Anestesia & Cuidados Crit, Madrid, Spain
关键词
complications; monitoring; postoperative care; recovery room; respiratory depression; respiratory rate; OXYGEN; PREVENTION; AGREEMENT; ACCURACY; CARE;
D O I
10.1093/bja/aes275
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Postoperative monitoring of ventilation is largely restricted to the measurement of haemoglobin-oxygen saturation (Sp(o2)) and respiratory rate (RR) derived from the ECG. Sp(o2) measurement is inadequate when used with supplemental oxygen and ECG-derived RR is subject to artifacts. A new monitor measures RR by quantifying the humidity of exhaled air (respiR8). The accuracy of the system was tested using a breathing simulator. In healthy volunteers, the respiR8 monitor was compared with two other methods of measuring RR: capnometry and counting of thoracic breathing movements. The ability of the monitor to track changes in RR resulting from the infusion of 2.5 g kg(1) fentanyl was assessed and compared with RR measured from a validated flow measurement system. The RR in 50 postoperative patients measured with the respiR8 was compared with that derived from the ECG. RR values were compared by population-based BlandAltman analyses. The respiR8 monitor was accurate in the range required in clinical practice. There was a close agreement between RR from respiR8, capnometry, and manual counting of respiratory movements without bias (limits of agreement 1 bpm). The respiR8 monitor was well able to accurately track RR changes from fentanyl. In postoperative patients, RR from respiR8 and ECG had a bias of 1.7 (5.7) bpm due to greater RR values observed from the ECG due to artifacts. The respiR8 gives an accurate measurement of RR and is useful in postoperative care.
引用
收藏
页码:981 / 989
页数:9
相关论文
共 50 条
  • [21] Contactless portable respiratory rate monitor (CPRM) accurately measures respiratory rate in children
    Daw, Will
    Kingshott, Ruth
    Sachi, Reza
    Elphick, Heather
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [22] Clinical validation of a contactless respiration rate monitor
    Bartosz Bujan
    Tobit Fischer
    Sarah Dietz-Terjung
    Aribert Bauerfeind
    Piotr Jedrysiak
    Martina Große Sundrup
    Janne Hamann
    Christoph Schöbel
    Scientific Reports, 13
  • [23] Clinical validation of a contactless respiration rate monitor
    Bujan, Bartosz
    Fischer, Tobit
    Dietz-Terjung, Sarah
    Bauerfeind, Aribert
    Jedrysiak, Piotr
    Sundrup, Martina Grosse
    Hamann, Janne
    Schoebel, Christoph
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [24] Prospective validation of smartphone-based heart rate and respiratory rate measurement algorithms
    Bae, Sean
    Borac, Silviu
    Emre, Yunus
    Wang, Jonathan
    Wu, Jiang
    Kashyap, Mehr
    Kang, Si-Hyuck
    Chen, Liwen
    Moran, Melissa
    Cannon, Julie
    Teasley, Eric S.
    Chai, Allen
    Yun, Liu
    Wadhwa, Neal
    Krainin, Michael
    Rubinstein, Michael
    Maciel, Alejandra
    McConnell, Michael V.
    Patel, Shwetak
    Corrado, Greg S.
    Taylor, James A.
    Zhan, Jiening
    Po, Ming Jack
    COMMUNICATIONS MEDICINE, 2022, 2 (01):
  • [25] Prospective validation of smartphone-based heart rate and respiratory rate measurement algorithms
    Sean Bae
    Silviu Borac
    Yunus Emre
    Jonathan Wang
    Jiang Wu
    Mehr Kashyap
    Si-Hyuck Kang
    Liwen Chen
    Melissa Moran
    Julie Cannon
    Eric S. Teasley
    Allen Chai
    Yun Liu
    Neal Wadhwa
    Michael Krainin
    Michael Rubinstein
    Alejandra Maciel
    Michael V. McConnell
    Shwetak Patel
    Greg S. Corrado
    James A. Taylor
    Jiening Zhan
    Ming Jack Po
    Communications Medicine, 2
  • [26] High accuracy of automated respiratory rate readings in a novel, non-contact home monitor
    Do, William
    Wheeler, Christopher
    De Vos, Maarten
    Russell, Richard
    Bafadhel, Mona
    EUROPEAN RESPIRATORY JOURNAL, 2021, 58
  • [27] A noninvasive method for monitoring respiratory rate of rats based on a microcantilever resonant humidity sensor
    Guan, Yangyang
    Le, Xianhao
    Hu, MingZhe
    Liu, Weixin
    Xie, Jin
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2019, 29 (12)
  • [28] pneuRIPTM: A Novel Respiratory Inductance Plethysmography Monitor
    Rahman, Tariq
    Page, Ralph
    Page, Christopher
    Bonnefoy, Jean-Remy
    Cox, Tim
    Shaffer, Thomas H.
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2017, 11 (01):
  • [29] NOVEL RESPIRATORY GAS VOLUME AND FLOW MONITOR
    MUSSELL, MJ
    JOURNAL OF BIOMEDICAL ENGINEERING, 1987, 9 (02): : 183 - 184
  • [30] Designing a Respiratory-Rate Monitor for Developing Countries
    Erickson H.
    Hargett Z.
    Batista J.
    Desjardins J.
    Dean D.
    IEEE Potentials, 2020, 39 (02): : 15 - 21