Positional Independence of Optic Nerve Head and Retinal Nerve Fiber Layer Thickness Measurements With Spectral-Domain Optical Coherence Tomography

被引:11
|
作者
Mansouri, Kaweh [1 ]
Liu, John H. K. [1 ]
Tafreshi, Ali [1 ]
Medeiros, Felipe A. [1 ]
Weinreb, Robert N. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
关键词
OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; POSTURAL CHANGE; DISK TOPOGRAPHY; EYES; REPRODUCIBILITY; AGREEMENT; ELEVATION; RATES;
D O I
10.1016/j.ajo.2012.03.049
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate repeatability and positional independence of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) thickness measurements in sitting and supine body positions using portable spectral-domain optical coherence tomography (iVue SD-OCT; Optovue Inc). DESIGN: Evaluation of diagnostic technology. METHODS: Sixty eyes of 30 subjects (10 healthy younger adults aged 20-27 years, 10 healthy older adults aged 50-66 years, and 10 glaucoma patients aged 38-82 years) were included prospectively. For each participant, all measurements were taken in a single session. After 5 minutes in the supine position, 5 scans were obtained from both eyes. Following a 5-minute sitting adaptation, 5 scans were then obtained in the sitting position. The same instrument was used for all measurements. Repeatability and correlation between supine and sitting measurements of 4 ONH and 3 RNFL parameters were assessed using intraclass correlation coefficients (ICC), concordance correlation coefficients (p), and Bland-Altman plots. RESULTS: Measurements were highly repeatable within individual eyes, both for ONH (ICC range, 73%-99%) and RNFL (ICC range, 72%-99%) parameters. The correlation between supine and sitting ONH measurements was strong and ranged from p = 97%-99% (younger healthy) to p = 98%-99% (older healthy) and p = 84%-99% (glaucoma). Bland-Altman plots indicated good agreement between sitting and supine readings of ONH and RNFL parameters. CONCLUSIONS: Repeatability of measurements of ONH and RNFL is high and measurements between sitting and supine are highly correlated. The ability of the iVue SD-OCT to evaluate ONH and RNFL parameters is good to excellent in both body positions. (Am J Ophthalmol 2012;154:712-721. (C) 2012 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:712 / 721
页数:10
相关论文
共 50 条
  • [31] Association of retinal nerve fibre layer and optic nerve head in spectral-domain optical coherence tomography with brain atrophy in multiple sclerosis
    Zimmermann, H. G.
    Freing, A.
    Oberwahrenbrock, T.
    Gaede, G.
    Kaufhold, F.
    Schippling, S.
    Wuerfel, J. T.
    Brandt, A. U.
    Paul, F.
    MULTIPLE SCLEROSIS JOURNAL, 2011, 17 : S259 - S259
  • [32] Assessment of central retinal thickness, choroidal thickness, and retinal nerve fiber layer in psoriasis: a spectral-domain optical coherence tomography study
    Asena Keles Sahin
    Fatma Etgü
    Aslihan Uzun
    BMC Ophthalmology, 21
  • [33] Assessment of central retinal thickness, choroidal thickness, and retinal nerve fiber layer in psoriasis: a spectral-domain optical coherence tomography study
    Sahin, Asena Keles
    Etgu, Fatma
    Uzun, Aslihan
    BMC OPHTHALMOLOGY, 2021, 21 (01)
  • [34] Evaluation of the reproducibility of retinal nerve fiber layer thickness and optic nerve head parameters with optical coherence tomography
    Rau, Ricardo
    de Freitas Silva, Andre Luiz
    Alves Salame, Andre Luiz
    Soares Melo Junior, Luiz Alberto
    REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (05) : 280 - 284
  • [35] Measurement of retinal nerve fiber layer and macular ganglion cell–inner plexiform layer with spectral-domain optical coherence tomography in patients with optic nerve head drusen
    Alfonso Casado
    Gema Rebolleda
    Laura Guerrero
    Marina Leal
    Inés Contreras
    Noelia Oblanca
    Francisco J. Muñoz-Negrete
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1653 - 1660
  • [36] Comparison of retinal nerve fiber layer thickness measurements by spectral-domain optical coherence tomography systems using a phantom eye model
    de Kinkelder, Roy
    de Bruin, Daniel M.
    Verbraak, Frank D.
    van Leeuwen, Ton G.
    Faber, Dirk J.
    JOURNAL OF BIOPHOTONICS, 2013, 6 (04) : 314 - 320
  • [37] Retinal Nerve Fiber Layer Imaging with Spectral-Domain Optical Coherence Tomography Analysis of the Retinal Nerve Fiber Layer Map for Glaucoma Detection
    Leung, Christopher K. S.
    Lam, Shi
    Weinreb, Robert N.
    Liu, Shu
    Ye, Cong
    Liu, Lan
    He, Jing
    Lai, Gilda W. K.
    Li, Taiping
    Lam, Dennis S. C.
    OPHTHALMOLOGY, 2010, 117 (09) : 1684 - 1691
  • [38] Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements
    Angmo, Dewang
    Bhartiya, Shibal
    Mishra, Sanjay K.
    Sharma, Reetika
    Poojari, Amar
    Dada, Tanuj
    NEPALESE JOURNAL OF OPHTHALMOLOGY, 2014, 6 (02) : 185 - 191
  • [39] Author Response: Retinal Nerve Fiber Layer Thickness Measurements in Rats with the Spectral Domain Optical Coherence Tomography
    Lange, Katharina
    Baehr, Mathias
    Hein, Katharina
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) : 3570 - 3571
  • [40] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Sood, Amit
    Paliwal, Rahul Omprakash
    Mishra, Rishu Yogesh
    GALICIAN MEDICAL JOURNAL, 2021, 28 (04)