Positional Independence of Optic Nerve Head and Retinal Nerve Fiber Layer Thickness Measurements With Spectral-Domain Optical Coherence Tomography

被引:11
|
作者
Mansouri, Kaweh [1 ]
Liu, John H. K. [1 ]
Tafreshi, Ali [1 ]
Medeiros, Felipe A. [1 ]
Weinreb, Robert N. [1 ]
机构
[1] Univ Calif San Diego, Dept Ophthalmol, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
关键词
OPEN-ANGLE GLAUCOMA; INTRAOCULAR-PRESSURE; POSTURAL CHANGE; DISK TOPOGRAPHY; EYES; REPRODUCIBILITY; AGREEMENT; ELEVATION; RATES;
D O I
10.1016/j.ajo.2012.03.049
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate repeatability and positional independence of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) thickness measurements in sitting and supine body positions using portable spectral-domain optical coherence tomography (iVue SD-OCT; Optovue Inc). DESIGN: Evaluation of diagnostic technology. METHODS: Sixty eyes of 30 subjects (10 healthy younger adults aged 20-27 years, 10 healthy older adults aged 50-66 years, and 10 glaucoma patients aged 38-82 years) were included prospectively. For each participant, all measurements were taken in a single session. After 5 minutes in the supine position, 5 scans were obtained from both eyes. Following a 5-minute sitting adaptation, 5 scans were then obtained in the sitting position. The same instrument was used for all measurements. Repeatability and correlation between supine and sitting measurements of 4 ONH and 3 RNFL parameters were assessed using intraclass correlation coefficients (ICC), concordance correlation coefficients (p), and Bland-Altman plots. RESULTS: Measurements were highly repeatable within individual eyes, both for ONH (ICC range, 73%-99%) and RNFL (ICC range, 72%-99%) parameters. The correlation between supine and sitting ONH measurements was strong and ranged from p = 97%-99% (younger healthy) to p = 98%-99% (older healthy) and p = 84%-99% (glaucoma). Bland-Altman plots indicated good agreement between sitting and supine readings of ONH and RNFL parameters. CONCLUSIONS: Repeatability of measurements of ONH and RNFL is high and measurements between sitting and supine are highly correlated. The ability of the iVue SD-OCT to evaluate ONH and RNFL parameters is good to excellent in both body positions. (Am J Ophthalmol 2012;154:712-721. (C) 2012 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:712 / 721
页数:10
相关论文
共 50 条
  • [21] Evaluation of retinal nerve fiber layer thickness in Alzheimer disease using spectral-domain optical coherence tomography
    Gunes, Alime
    Demirci, Seden
    Tok, Levent
    Tok, Ozlem
    Demirci, Serpil
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2015, 45 (05) : 1094 - 1097
  • [22] Retinal Nerve Fiber Layer Thickness in Children <18 Years by Spectral-domain Optical Coherence Tomography
    Rao, Aparna
    Sahoo, Bhaktiprada
    Kumar, Mukesh
    Varshney, Gopal
    Kumar, Ramesh
    SEMINARS IN OPHTHALMOLOGY, 2013, 28 (02) : 97 - 102
  • [23] Reproducibility of Retinal Nerve Fiber Thickness Measurements Using Spectral-Domain Optical Coherence Tomography in Glaucoma Patients
    Monsalve, B.
    Ferreras, A.
    Pajarin, A. B.
    Pablo, L. E.
    Urcelay, J. L.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [24] Evaluation of Peripapillary Retinal Nerve Fiber Layer Thickness in Myopic Eyes by Spectral-domain Optical Coherence Tomography
    Salih, Payman A-K. Mohammad
    JOURNAL OF GLAUCOMA, 2012, 21 (01) : 41 - 44
  • [25] Agreement Among Spectral-Domain Optical Coherence Tomography Instruments for Assessing Retinal Nerve Fiber Layer Thickness
    Leite, Mauro T.
    Rao, Harsha L.
    Weinreb, Robert N.
    Zangwill, Linda M.
    Bowd, Christopher
    Sample, Pamela A.
    Tafreshi, Ali
    Medeiros, Felipe A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 151 (01) : 85 - 92
  • [26] Evaluation of Retinal Nerve Fiber Layer Thickness in Acromegalic Patients Using Spectral-Domain Optical Coherence Tomography
    Duru, Necati
    Ersoy, Reyhan
    Altinkaynak, Hasan
    Duru, Zeynep
    Cagil, Nurullah
    Cakir, Bekir
    SEMINARS IN OPHTHALMOLOGY, 2016, 31 (03) : 285 - 290
  • [27] Relationship Between Optic Nerve Appearance and Retinal Nerve Fiber Layer Thickness as Explored with Spectral Domain Optical Coherence Tomography
    Aleman, Tomas S.
    Huang, Jiayan
    Garrity, Sean T.
    Carter, Stuart B.
    Aleman, Wendy D.
    Ying, Gui-shuang
    Tamhankar, Madhura A.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2014, 3 (06):
  • [28] Retinal Nerve Fiber Layer Thickness Using Spectral-Domain Optical Coherence Tomography in Patients With No Light Perception Secondary to Optic Atrophy
    Groth, Sylvia L.
    Harrison, Andrew
    Grajewski, Alana L.
    Lee, Michael S.
    JOURNAL OF NEURO-OPHTHALMOLOGY, 2013, 33 (01) : 37 - 39
  • [29] Myopic Optic Disc Tilt and the Characteristics of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Spectral-domain Optical Coherence Tomography
    Hwang, Young Hoon
    Yoo, Chungkwon
    Kim, Yong Yeon
    JOURNAL OF GLAUCOMA, 2012, 21 (04) : 260 - 265
  • [30] Influence of Cataract on Retinal Nerve Fiber Layer Measurements in Time-Domain and Spectral-Domain Optical Coherence Tomography
    Kim, N.
    Lee, H.
    Lee, E.
    Kim, J.
    Byeon, S.
    Kim, S.
    Hong, S.
    Seong, G.
    Kim, C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)