Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging

被引:98
|
作者
Sudarski, Sonja [1 ]
Apfaltrer, Paul [1 ]
Nance, John W., Jr. [2 ]
Schneider, David [1 ]
Meyer, Mathias [1 ]
Schoenberg, Stefan O. [1 ]
Fink, Christian [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
[2] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
关键词
CT angiography; Dual-source CT; Dual-energy CT; Monoenergetic Image quality; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CONTRAST; QUALITY; SUBTRACTION; ARTERIES; REMOVAL; REPAIR;
D O I
10.1016/j.ejrad.2013.04.040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare objective image quality indices in dual-energy CT angiography (DE-CTA) studies of the abdomen and lower extremity using conventional polyenergetic images (PEIs) and virtual monoenergetic images (MEIs) at different kiloelectron volt (keV) levels. Methods: We retrospectively evaluated 68 dual-source DE-CTA studies. 50 patients (42 men, 71 +/- 10 years) underwent abdominal DE-CTA. 18 patients (13 men, 67 +/- 10 years) underwent lower extremity DE-CTA. MEIs from 40 to 120 keV were reconstructed. Signal intensity, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed in infrarenal aorta, superior mesenteric, external iliac, femoral, popliteal, and lower leg arteries. Comparisons between MEIs and PEIs were performed with Dunnett's test. Results: 222 arteries were evaluated. In abdominal arteries 70 keV MEIs showed statistically equal signal intensity, noise and CNR levels (+13%; +31%, -14% on average; all p > 0.05) compared to PEIs; SNR was equal or slightly impaired (-7% on average; p < 0.001-1.00). In lower extremity arteries 60 keV MEIs resulted in significantly higher signal intensity and CNR (+54%; +54% on average; all p < 0.05) compared to PEIs at equal noise levels (+18% on average; all p > 0.05) and equal or higher SNR (+49% on average; p < 0.01-0.35). Conclusions: Low-keV MEIs lead to equal or higher signal intensity and CNR compared to PEIs. In lower extremity DE-CTA, additional reconstruction of low-keV MEIs at 60 keV might increase diagnostic confidence. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E574 / E581
页数:8
相关论文
共 50 条
  • [41] Phantom-based optimization of virtual monoenergetic image reconstruction in dual-energy CT
    Richter, Anne
    Razinskas, Gary
    Weick, Stefan
    Lutyj, Paul
    Kraft, Johannes
    Wittig-Sauerwein, Andrea
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3848 - S3849
  • [42] Improved Imaging of intraspinal Lymphomas by means of virtual monoenergetic Reconstructions of Dual-energy CT
    Hokamp, Nils Grosse
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2018, 190 (07): : 638 - +
  • [43] Dual-energy CT angiography of pelvic and lower extremity arteries: dual-energy bone subtraction versus manual bone subtraction
    Yamamoto, S.
    McWilliams, J.
    Arellano, C.
    Marfori, W.
    Cheng, W.
    McNamara, T.
    Quinones-Baldrich, W. J.
    Ruehm, S. G.
    CLINICAL RADIOLOGY, 2009, 64 (11) : 1088 - 1096
  • [44] Pancreatic cancer detection with dual-energy CT: diagnostic performance of 40 keV and 70 keV virtual monoenergetic images
    Yoshifumi Noda
    Tomohiro Ando
    Tetsuro Kaga
    Nao Yamda
    Takuya Seko
    Takuma Ishihara
    Nobuyuki Kawai
    Toshiharu Miyoshi
    Akio Ito
    Takuya Naruse
    Fuminori Hyodo
    Hiroki Kato
    Avinash R. Kambadakone
    Masayuki Matsuo
    La radiologia medica, 2024, 129 : 677 - 686
  • [45] Virtual unenhanced imaging of the liver with third-generation dual-source dual-energy CT and advanced modeled iterative reconstruction
    De Cecco, Carlo N.
    Muscogiuri, Giuseppe
    Schoepf, U. Joseph
    Caruso, Damiano
    Wichmann, Julian L.
    Cannao, Paola M.
    Canstein, Christian
    Fuller, Stephen R.
    Snider, Lauren
    Varga-Szemes, Akos
    Hardie, Andrew D.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (07) : 1257 - 1264
  • [46] Pancreatic cancer detection with dual-energy CT: diagnostic performance of 40 keV and 70 keV virtual monoenergetic images
    Noda, Yoshifumi
    Ando, Tomohiro
    Kaga, Tetsuro
    Yamda, Nao
    Seko, Takuya
    Ishihara, Takuma
    Kawai, Nobuyuki
    Miyoshi, Toshiharu
    Ito, Akio
    Naruse, Takuya
    Hyodo, Fuminori
    Kato, Hiroki
    Kambadakone, Avinash R.
    Matsuo, Masayuki
    RADIOLOGIA MEDICA, 2024, 129 (05): : 677 - 686
  • [47] Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography
    D'Angelo, Tommaso
    Bucher, Andreas M.
    Lenga, Lukas
    Arendt, Christophe T.
    Peterke, Julia L.
    Caruso, Damiano
    Mazziotti, Silvio
    Blandino, Alfredo
    Ascenti, Giorgio
    Othman, Ahmed E.
    Martin, Simon S.
    Leithner, Doris
    Vogl, Thomas J.
    Wichmann, Julian L.
    EUROPEAN RADIOLOGY, 2018, 28 (04) : 1393 - 1401
  • [48] Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen
    Albrecht, Moritz H.
    Trommer, Jesko
    Wichmann, Julian L.
    Scholtz, Jan-Erik
    Martin, Simon S.
    Lehnert, Thomas
    Vogl, Thomas J.
    Bodelle, Boris
    INVESTIGATIVE RADIOLOGY, 2016, 51 (09) : 582 - 590
  • [49] Application of an Advanced Image-Based Virtual Monoenergetic Reconstruction of Dual Source Dual-Energy CT Data at Low keV Increases Image Quality for Routine Pancreas Imaging
    Hardie, Andrew D.
    Picard, Melissa M.
    Camp, E. Ramsay
    Perry, Jonathan D.
    Suranyi, Pal
    De Cecco, Carlo N.
    Schoepf, U. Joseph
    Wichmann, Julian L.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 716 - 720
  • [50] Optimisation of window settings for traditional and noise-optimised virtual monoenergetic imaging in dual-energy computed tomography pulmonary angiography
    Tommaso D’Angelo
    Andreas M. Bucher
    Lukas Lenga
    Christophe T. Arendt
    Julia L. Peterke
    Damiano Caruso
    Silvio Mazziotti
    Alfredo Blandino
    Giorgio Ascenti
    Ahmed E. Othman
    Simon S. Martin
    Doris Leithner
    Thomas J. Vogl
    Julian L. Wichmann
    European Radiology, 2018, 28 : 1393 - 1401