Optimization of keV-settings in abdominal and lower extremity dual-source dual-energy CT angiography determined with virtual monoenergetic imaging

被引:98
|
作者
Sudarski, Sonja [1 ]
Apfaltrer, Paul [1 ]
Nance, John W., Jr. [2 ]
Schneider, David [1 ]
Meyer, Mathias [1 ]
Schoenberg, Stefan O. [1 ]
Fink, Christian [1 ]
Henzler, Thomas [1 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Univ Med Ctr Mannheim, Inst Clin Radiol & Nucl Med, D-68167 Mannheim, Germany
[2] Johns Hopkins Univ Hosp, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD 21287 USA
关键词
CT angiography; Dual-source CT; Dual-energy CT; Monoenergetic Image quality; COMPUTED-TOMOGRAPHY ANGIOGRAPHY; CONTRAST; QUALITY; SUBTRACTION; ARTERIES; REMOVAL; REPAIR;
D O I
10.1016/j.ejrad.2013.04.040
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare objective image quality indices in dual-energy CT angiography (DE-CTA) studies of the abdomen and lower extremity using conventional polyenergetic images (PEIs) and virtual monoenergetic images (MEIs) at different kiloelectron volt (keV) levels. Methods: We retrospectively evaluated 68 dual-source DE-CTA studies. 50 patients (42 men, 71 +/- 10 years) underwent abdominal DE-CTA. 18 patients (13 men, 67 +/- 10 years) underwent lower extremity DE-CTA. MEIs from 40 to 120 keV were reconstructed. Signal intensity, noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were assessed in infrarenal aorta, superior mesenteric, external iliac, femoral, popliteal, and lower leg arteries. Comparisons between MEIs and PEIs were performed with Dunnett's test. Results: 222 arteries were evaluated. In abdominal arteries 70 keV MEIs showed statistically equal signal intensity, noise and CNR levels (+13%; +31%, -14% on average; all p > 0.05) compared to PEIs; SNR was equal or slightly impaired (-7% on average; p < 0.001-1.00). In lower extremity arteries 60 keV MEIs resulted in significantly higher signal intensity and CNR (+54%; +54% on average; all p < 0.05) compared to PEIs at equal noise levels (+18% on average; all p > 0.05) and equal or higher SNR (+49% on average; p < 0.01-0.35). Conclusions: Low-keV MEIs lead to equal or higher signal intensity and CNR compared to PEIs. In lower extremity DE-CTA, additional reconstruction of low-keV MEIs at 60 keV might increase diagnostic confidence. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E574 / E581
页数:8
相关论文
共 50 条
  • [21] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Long-Jiang Zhang
    Jin Peng
    Sheng-Yong Wu
    Z. Jane Wang
    Xin-Sheng Wu
    Chang-Sheng Zhou
    Xue-Man Ji
    Guang-Ming Lu
    European Radiology, 2010, 20 : 2257 - 2264
  • [22] Liver virtual non-enhanced CT with dual-source, dual-energy CT: a preliminary study
    Zhang, Long-Jiang
    Peng, Jin
    Wu, Sheng-Yong
    Wang, Z. Jane
    Wu, Xin-Sheng
    Zhou, Chang-Sheng
    Ji, Xue-Man
    Lu, Guang-Ming
    EUROPEAN RADIOLOGY, 2010, 20 (09) : 2257 - 2264
  • [23] Abdominal dual-source dual-energy CT: Uses in clinical practice (vol 42, 2013)
    Siegel, Marilyn J.
    APPLIED RADIOLOGY, 2013, 42 (12) : 2 - 2
  • [24] Advanced virtual monoenergetic images: improving the contrast of dual-energy CT pulmonary angiography
    Meier, A.
    Wurnig, M.
    Desbiolles, L.
    Leschka, S.
    Frauenfelder, T.
    Alkadhi, H.
    CLINICAL RADIOLOGY, 2015, 70 (11) : 1244 - 1251
  • [25] Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual-Energy CT Projection Data
    Ferrero, A.
    Chen, B.
    Huang, A.
    Montoya, J.
    Yu, L.
    McCollough, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3658 - 3659
  • [26] Spectral Optimization of Chest CT Angiography with Reduced Iodine Load: Experience in 80 Patients Evaluated with Dual-Source, Dual-Energy CT
    Delesalle, Marie-Aurelie
    Pontana, Francois
    Duhamel, Alain
    Faivre, Jean-Baptiste
    Flohr, Thomas
    Tacelli, Nunzia
    Remy, Jacques
    Remy-Jardin, Martine
    RADIOLOGY, 2013, 267 (01) : 256 - 266
  • [27] Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast
    Moritz H. Albrecht
    Jan-Erik Scholtz
    Kristina Hüsers
    Martin Beeres
    Andreas M. Bucher
    Moritz Kaup
    Simon S. Martin
    Sebastian Fischer
    Boris Bodelle
    Ralf W. Bauer
    Thomas Lehnert
    Thomas J. Vogl
    Julian L. Wichmann
    European Radiology, 2016, 26 : 1863 - 1870
  • [28] Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source Dual-Energy CT
    Durieux, Pierre
    Gevenois, Pierre Alain
    Van Muylem, Alain
    Howarth, Nigel
    Keyzer, Caroline
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : 1042 - 1058
  • [29] Role of Virtual Monoenergetic Images in the Assessment of Vessel Enhancement in Segmental Level in Third-Generation Dual-Source Dual-Energy CT Pulmonary Angiography-A Prospective Study
    Ethiraju, Vijayakumaran
    Varatharajaperumal, Rajeshkumar
    Arunachalam, Venkatesh Kasi
    KuruVambath, Abdulla
    Punniyakotti, Rajesh Shanmugam
    Rajasekaran, Sriman
    Mehta, Pankaj
    Cherian, Mathew
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2024,
  • [30] Advanced image-based virtual monoenergetic dual-energy CT angiography of the abdomen: optimization of kiloelectron volt settings to improve image contrast
    Albrecht, Moritz H.
    Scholtz, Jan-Erik
    Huesers, Kristina
    Beeres, Martin
    Bucher, Andreas M.
    Kaup, Moritz
    Martin, Simon S.
    Fischer, Sebastian
    Bodelle, Boris
    Bauer, Ralf W.
    Lehnert, Thomas
    Vogl, Thomas J.
    Wichmann, Julian L.
    EUROPEAN RADIOLOGY, 2016, 26 (06) : 1863 - 1870