Comparison of Balloon Catheter Ablation Technologies for Pulmonary Vein Isolation: The Laser Versus Cryo Study

被引:41
|
作者
Bordignon, Stefano [1 ]
Chun, K. R. Julian [1 ]
Gunawardene, Melanie [1 ]
Fuernkranz, Alexander [1 ]
Urban, Verena [1 ]
Schulte-Hahn, Britta [1 ]
Nowak, Bernd [1 ]
Schmidt, Boris [1 ]
机构
[1] Cardioangiol Ctr Bethanien, D-60431 Frankfurt, Germany
关键词
atrial fibrillation; catheter ablation; cryoballoon; laser; phrenic nerve; PAROXYSMAL ATRIAL-FIBRILLATION; ANTIARRHYTHMIC-DRUG THERAPY; BIG CRYOBALLOON TECHNIQUE; LUMEN MAPPING CATHETER; TRIAL; EFFICACY; FEASIBILITY; MANAGEMENT; INSIGHTS; SYSTEM;
D O I
10.1111/jce.12192
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Laser- Versus CryoBalloon for PVI. Introduction: Balloon catheters have been developed to facilitate pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF). We sought to compare the safety and efficacy of the cryoballoon (CB) and the laserballoon (LB) in a pilot study. Methods and Results: One hundred and forty patients with drug-refractory PAF were prospectively allocated in a 1: 1 fashion to undergo a PVI procedure with the 28 mm CB or the LB and were followed for 12 months using 3-day Holter ECG recording. The primary efficacy endpoint was a documented AF recurrence >= 30 seconds between 90 and 365 days after the index ablation. In total, 269 of 270 PVs (99.6%) and 270 of 273 PVs (98.9%) were acutely isolated in the CB and LB group, respectively. Mean procedural time was 136 +/- 30 minutes for the CB group and 144 +/- 33 minutes for the LB group (P = 0.13). Mean fluoroscopy time was longer in the CB group (21 +/- 9 minutes vs 15 +/- 6 minutes; P < 0.001). During 12 months follow-up, 37% of patients in the CB group and 27% in the LB group experienced an AF recurrence (P = 0.18). Phrenic nerve palsies occurred in 5.7% (CB) and 4.2% (LB) of patients, respectively. Conclusion: Balloon catheters are a viable option to safely perform a PVI procedure in patients with drug-refractory PAF. Ninety-nine percent of PVs may be acutely isolated with a single balloon catheter. The AF free survival rate after a single ablation procedure was not statistically different between groups.
引用
收藏
页码:987 / 994
页数:8
相关论文
共 50 条
  • [21] Occlusion of pulmonary veins with cryo balloon catheter as a basic prerequisite for successful pulmonary vein isolation - comparison between contrast medium injection and wedge pressure
    Kuniss, M.
    Neumann, T.
    Zaltsberg, S.
    Erkapic, D.
    Berkowitsch, A.
    Pajitnev, D.
    Pitschner, H. F.
    EUROPEAN HEART JOURNAL, 2010, 31 : 557 - 557
  • [22] Pulmonary vein isolation with the radiofrequency balloon catheter: a single centre prospective study
    Del Monte, Alvise
    Almorad, Alexandre
    Pannone, Luigi
    Della Rocca, Domenico Giovanni
    Bisignani, Antonio
    Monaco, Cinzia
    Mouram, Sahar
    Ramak, Robbert
    Gauthey, Anais
    Overeinder, Ingrid
    Bala, Gezim
    Sorgente, Antonio
    Stroker, Erwin
    Sieira, Juan
    Brugada, Pedro
    La Meir, Mark
    Chierchia, Gian-Battista
    de Asmundis, Carlo
    EUROPACE, 2023, 25 (03): : 896 - 904
  • [23] First Belgian experience with the Endoscopic laser balloon Ablation System for pulmonary vein isolation
    Koopman, Pieter
    ten Haken, Jeff
    Vanduynhoven, Philippe
    Dilling, Dagmara
    Schurmans, Joris
    Heidbuchel, Hein
    Vijgen, Johan
    ACTA CARDIOLOGICA, 2016, 71 (01) : 81 - 82
  • [24] First Belgian Experience with the Endoscopic Laser Balloon Ablation System for Pulmonary Vein Isolation
    Koopman, Pieter
    Ten Haken, Jeff
    Vanduynhoven, Philippe
    Dilling, Dagmara
    Schurmans, Joris
    Heidbuchel, Hein
    Vijgen, Johan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (05) : 643 - 644
  • [25] Pulmonary Vein Stenosis After Catheter Ablation of Atrial Fibrillation Using a Cryoballoon, Hot Balloon, or Laser Balloon
    Tokuda, Michifumi
    Yamashita, Seigo
    Shiomi, Satoko
    Sakurai, Ryutaro
    Sato, Hidenori
    Oseto, Hirotsuna
    Yokoyama, Masaaki
    Tokutake, Kenichi
    Kato, Mika
    Narui, Ryohsuke
    Tanigawa, Shin-ichi
    Yoshimura, Michihiro
    Yamane, Teiichi
    CIRCULATION JOURNAL, 2023, 87 (12) : 1711 - +
  • [26] SAFETY AND EFFICACY PROFILE OF PULMONARY VEIN ISOLATION USING CRYOBALLOON ABLATION VERSUS LASER BALLOON ABLATION FOR PATIENTS WITH PAROXYSMAL ATRIAL FIBRILLATION
    Magdon, Dorota
    Mounir, Abdulghani
    Ali, Mahmoud
    Erickson, Lynn
    Adefisoye, James
    Kieu, Andy
    Malik, Abdullah
    Ajam, Tarek
    Premjee, Mohammed M.
    Jahangir, Arshad
    Mortada, M. Eyman
    Bhatia, Atul
    Niazi, Imran
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 68 - 68
  • [27] Comparison of single ablation catheter versus multipolar mapping catheter for assessment of pulmonary vein conduction
    Paisey, J. R.
    Tomlinson, D.
    de Bono, J.
    Rajappan, K.
    Bashir, Y.
    Betts, T.
    HEART, 2008, 94 : A101 - A101
  • [28] Time to isolation guided hot balloon ablation for pulmonary vein isolation
    Chikata, A.
    Kato, T.
    Usuda, K.
    Fujita, S.
    Maruyama, M.
    Otowa, K.
    Takashima, S.
    Murai, H.
    Usui, S.
    Furusho, H.
    Kaneko, S.
    Takamura, M.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1793 - 1793
  • [29] Cryo Balloon Pulmonary Vein Isolation Is it Really All So "Simple"?
    Ernst, Sabine
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (16) : 1724 - 1725
  • [30] Utility of Intracardiac Ultrasound Imaging to Guide Pulmonary Vein Ablation Using Laser Balloon Catheter
    Leite, Luiz
    Su, Wilber
    Johnson, Susan B.
    Milton, Mark
    Henz, Benhur
    Sarabanda, Alvaro
    Santos, Simone N.
    Packer, Douglas L.
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2009, 93 (06) : 666 - 671