Astigmatism Correction With Toric IOL: Analysis of Visual Performance, Position, and Wavefront Error

被引:15
|
作者
Toto, Lisa [1 ,2 ]
Vecchiarino, Luca [1 ,2 ]
D'Ugo, Erminia [1 ,2 ]
Cardone, Daniela [5 ]
Mastropasqua, Alessandra [6 ]
Mastropasqua, Rodolfo [7 ]
Di Nicola, Marta [3 ,4 ]
机构
[1] G dAnnunzio Univ Chieti Pescara, Dept Med, Chieti, Italy
[2] G dAnnunzio Univ Chieti Pescara, Sci Ageing Eye Clin, Chieti, Italy
[3] G dAnnunzio Univ Chieti Pescara, G dAnnunzio Univ Fdn, Ctr Excellence Aging, Chieti, Italy
[4] G dAnnunzio Univ Chieti Pescara, G dAnnunzio Univ Fdn, Dept Biomed Sci, Lab Biostat, Chieti, Italy
[5] G dAnnunzio Univ Chieti Pescara, G dAnnunzio Fdn, Inst Adv Biomed Technol, Dept Neurosci & Imaging, Chieti, Italy
[6] Univ Rome, Ophthalm Clin, Rome, Italy
[7] Univ Verona, Ophthalm Clin, I-37100 Verona, Italy
关键词
INTRAOCULAR-LENS IMPLANTATION; ROTATIONAL STABILITY; CATARACT-SURGERY; VECTOR ANALYSIS;
D O I
10.3928/1081597X-20130617-06
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate astigmatism correction, visual performance, intraocular lens (IOL) position, and wavefront error after implantation of toric IOLs in patients with cataract. METHODS: This prospective study comprised 30 eyes of 30 patients with cataract who were candidates for phacoemulsification and implantation of the AcrySof toric IOL (Alcon Laboratories, Inc., Fort Worth, TX). Mean preoperative corneal keratometric and subjective refractive cylinder were 2.10 +/- 0.47 and 2.17 +/- 0.41 diopters (D), respectively. RESULTS: The refractive cylinder decreased significantly from 2.17 +/- 0.41 to 0.73 +/- 0.45 D (P = .001) at 180 days postoperatively. The difference between preoperative corneal astigmatism and postoperative refractive astigmatism was statistically signifi cant (P < .05). At 180 days postoperatively, the uncorrected distance visual acuity was 0.20 logMAR (Snellen 20/32) in 100% of patients and 0.0 logMAR (Snellen 20/20) in 64% of patients. The root mean square of internal coma and trefoil aberrations showed a trend toward reduction; internal spherical aberration significantly decreased, whereas corneal trefoil aberration significantly increased (P < .05). A low amount of IOL decentration and tilt were detected at 30 and 180 days postoperatively, respectively. CONCLUSIONS: Toric IOL implantation is an effective procedure for correction of preexisting corneal astigmatism, improving visual performance, and inducing a low amount of higher-order aberrations. Moreover, the toric IOLs is well positioned early after surgery and stable over time.
引用
收藏
页码:476 / 483
页数:8
相关论文
共 50 条
  • [41] Improving Error Performance of Dicode Pulse Position Modulation System using Forward Error Correction Codes
    Al-Nedawe, Basman M.
    Buhafa, Adel M.
    Sibley, Martin J. N.
    Mather, Peter J.
    2013 21ST TELECOMMUNICATIONS FORUM (TELFOR), 2013, : 331 - 334
  • [42] Comparison of FDA-Reported Visual and Refractive Outcomes of the Toric ICL Lens, SMILE, and Topography-Guided LASIK for the Correction of Myopia and Myopic Astigmatism
    Moshirfar, Majid
    Somani, Anisha N.
    Motlagh, Mahsaw N.
    Vaidyanathan, Uma
    Sumsion, Jorgen S.
    Barnes, James R.
    Ronquillo, Yasmyne C.
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (11) : 699 - +
  • [43] Performance Analysis of the Wavefront Sensor in Active Correction of the INO340 Telescope
    Shomali, R.
    Khosroshahi, H.
    Saeedifar, M.
    Fatemi, S.
    Altafi, H.
    GROUND-BASED AND AIRBORNE TELESCOPES IX, 2022, 12182
  • [44] Error analysis of monocular visual position measurement based on coplanar feature points
    Cui, J.-S. (cuijiashan@gmail.com), 1600, Chinese Optical Society (43):
  • [46] Comparative Analysis of the Visual Performance After Cataract Surgery With Implantation of a Bifocal or Trifocal Diffractive IOL
    Mojzis, Peter
    Kukuckova, Lucia
    Majerova, Katarina
    Liehneova, Katerina
    Pinero, David P.
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (10) : 666 - U23
  • [47] PERFORMANCE ANALYSIS AND IMPROVED DETECTION FOR DMSK WITH NONREDUNDANT ERROR CORRECTION
    WEINING, H
    IEE PROCEEDINGS-I COMMUNICATIONS SPEECH AND VISION, 1990, 137 (06): : 431 - 437
  • [48] Analysis of error performance for Turbo coded pulse position width modulation
    黄爱萍
    樊养余
    李伟
    王凤琴
    谭庆贵
    Optoelectronics Letters, 2009, 5 (05) : 376 - 379
  • [49] Analysis of error performance for Turbo coded pulse position width modulation
    Huang A.-P.
    Fan Y.-Y.
    Li W.
    Wang F.-Q.
    Tan Q.-G.
    Optoelectron. Lett., 2009, 5 (376-379): : 376 - 379
  • [50] Comparative study of Acrysof ReSTOR multifocal intraocular lenses +4.00 D and +3.00 D: visual performance and wavefront error
    Toto, Lisa
    Carpineto, Paolo
    Falconio, Gennaro
    Agnifili, Luca
    Di Nicola, Marta
    Mastropasqua, Alessandra
    Mastropasqua, Leonardo
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (03) : 295 - 302