Astigmatism Correction With Toric IOL: Analysis of Visual Performance, Position, and Wavefront Error

被引:15
|
作者
Toto, Lisa [1 ,2 ]
Vecchiarino, Luca [1 ,2 ]
D'Ugo, Erminia [1 ,2 ]
Cardone, Daniela [5 ]
Mastropasqua, Alessandra [6 ]
Mastropasqua, Rodolfo [7 ]
Di Nicola, Marta [3 ,4 ]
机构
[1] G dAnnunzio Univ Chieti Pescara, Dept Med, Chieti, Italy
[2] G dAnnunzio Univ Chieti Pescara, Sci Ageing Eye Clin, Chieti, Italy
[3] G dAnnunzio Univ Chieti Pescara, G dAnnunzio Univ Fdn, Ctr Excellence Aging, Chieti, Italy
[4] G dAnnunzio Univ Chieti Pescara, G dAnnunzio Univ Fdn, Dept Biomed Sci, Lab Biostat, Chieti, Italy
[5] G dAnnunzio Univ Chieti Pescara, G dAnnunzio Fdn, Inst Adv Biomed Technol, Dept Neurosci & Imaging, Chieti, Italy
[6] Univ Rome, Ophthalm Clin, Rome, Italy
[7] Univ Verona, Ophthalm Clin, I-37100 Verona, Italy
关键词
INTRAOCULAR-LENS IMPLANTATION; ROTATIONAL STABILITY; CATARACT-SURGERY; VECTOR ANALYSIS;
D O I
10.3928/1081597X-20130617-06
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate astigmatism correction, visual performance, intraocular lens (IOL) position, and wavefront error after implantation of toric IOLs in patients with cataract. METHODS: This prospective study comprised 30 eyes of 30 patients with cataract who were candidates for phacoemulsification and implantation of the AcrySof toric IOL (Alcon Laboratories, Inc., Fort Worth, TX). Mean preoperative corneal keratometric and subjective refractive cylinder were 2.10 +/- 0.47 and 2.17 +/- 0.41 diopters (D), respectively. RESULTS: The refractive cylinder decreased significantly from 2.17 +/- 0.41 to 0.73 +/- 0.45 D (P = .001) at 180 days postoperatively. The difference between preoperative corneal astigmatism and postoperative refractive astigmatism was statistically signifi cant (P < .05). At 180 days postoperatively, the uncorrected distance visual acuity was 0.20 logMAR (Snellen 20/32) in 100% of patients and 0.0 logMAR (Snellen 20/20) in 64% of patients. The root mean square of internal coma and trefoil aberrations showed a trend toward reduction; internal spherical aberration significantly decreased, whereas corneal trefoil aberration significantly increased (P < .05). A low amount of IOL decentration and tilt were detected at 30 and 180 days postoperatively, respectively. CONCLUSIONS: Toric IOL implantation is an effective procedure for correction of preexisting corneal astigmatism, improving visual performance, and inducing a low amount of higher-order aberrations. Moreover, the toric IOLs is well positioned early after surgery and stable over time.
引用
收藏
页码:476 / 483
页数:8
相关论文
共 50 条
  • [31] Vector analysis of small incision lenticule extraction and toric implantable collamer lens implantation for astigmatism correction
    Wan, Ting
    Yin, Houfa
    Wu, Zhiyi
    Yang, Yabo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (03) : 994 - 1001
  • [32] Rotational stability and visual outcome after implantation of a new toric intraocular lens for the correction of corneal astigmatism during cataract surgery
    Bachernegg, Alexander
    Rueckl, Theresa
    Riha, Wolfgang
    Grabner, Guenther
    Dexl, Alois K.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (09): : 1390 - 1398
  • [33] Toric contact lens correction improves functional near visual performance with digital devices
    Read, Scott A.
    Vincent, Stephen J.
    Colorado, Luisa H.
    Wood, Joanne M.
    Collins, Michael J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [34] Error analysis and correction in wavefront reconstruction from the transport-of-intensity equation
    Barbero, Sergio
    Thibos, Larry N.
    OPTICAL ENGINEERING, 2006, 45 (09)
  • [35] Real World Visual Performance and Patient Satisfaction outcomes of a novel Wavefront-Shaping Presbyopia-Correcting IOL
    Lapid-Gortzak, R.
    Perez-Vives, C.
    ACTA OPHTHALMOLOGICA, 2022, 100 : 35 - 35
  • [36] Visual performance in cataract patients with low levels of postoperative astigmatism: full correction versus spherical equivalent correction
    Lehmann, Robert P.
    Houtman, Diane M.
    CLINICAL OPHTHALMOLOGY, 2012, 6 : 333 - 338
  • [37] Trajectory correction and position error analysis of underwater laser scanning
    Yuan, Hai-lu
    Zhang, He
    Zha, Bing-ting
    Ding, Li-bo
    OPTICS AND LASER TECHNOLOGY, 2022, 153
  • [38] Improvement of Visual Performance by Astigmatism Correction in Myopic Eyes Wearing RGP-Contact Lens
    Bao, I.
    He, I.
    Wang, H.
    Mao, X.
    Lu, F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [39] Femtosecond laser-assisted astigmatic keratotomy versus toric IOL implantation for correcting astigmatism in cataract patients: a systematic review and meta-analysis with trial sequential analysis
    Yen, Wei-Ting
    Weng, Tzu-Heng
    Lin, Ting-Yi
    Tai, Ming-Cheng
    Chen, Yi-Hao
    Chang, Yu-Min
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2024,
  • [40] Visual outcomes and patient satisfaction after implantable collamer lens and Toric implantable collamer lens correction for moderate to high myopia and myopic astigmatism
    Bamashmus, Mahfouth A.
    Al-Arabi, Ammar H.
    Alawad, Mohammed A.
    SAUDI MEDICAL JOURNAL, 2013, 34 (09) : 913 - 919