Investigation of mass attenuation coefficients of water, concrete and bakelite at different energies using the FLUKA Monte Carlo code

被引:49
|
作者
Demir, Nilgun [1 ]
Tarim, Urkiye Akar [1 ]
Popovici, Maria-Ana [2 ]
Demirci, Zehra Nur [3 ]
Gurler, Orhan [1 ]
Akkurt, Iskender [3 ]
机构
[1] Uludag Univ, Fac Arts & Sci, Dept Phys, TR-16059 Bursa, Turkey
[2] Univ Politehn Bucuresti, Dept Phys, Bucharest, Romania
[3] Suleyman Demirel Univ, Fen Edebiyat Fak Fizik, TR-32200 Isparta, Turkey
关键词
Water; Bakelite; Concrete; FLUKA; Energy deposition; Mass attenuation coefficient; GAMMA-RAY; SHIELDING PROPERTIES; THICKNESS;
D O I
10.1007/s10967-013-2494-y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The mass attenuation coefficients of water, bakelite and concrete sample defined in the simulation package were obtained using the FLUKA Monte Carlo code at 59.5, 80.9, 140.5, 356.5, 661.6, 1173.2 and 1332.5 keV photon energies. The results for the mass attenuation coefficients obtained by simulation have been compared with experimental and the theoretical ones and good agreement has been observed. The results indicate that this process can be followed to determine the data on the attenuation of gamma-rays with the several energies in other materials. Also, the deposited energy by 661.6 keV photons at several thicknesses of each media was determined as being an important data for radiation shielding studies.
引用
收藏
页码:1303 / 1307
页数:5
相关论文
共 50 条
  • [41] Activity coefficients in sea water using Monte Carlo simulations
    Lund, M
    Jönsson, B
    Pedersen, T
    MARINE CHEMISTRY, 2003, 80 (2-3) : 95 - 101
  • [42] Monte Carlo calculations for gamma-ray mass attenuation coefficients of some soil samples
    Tarim, U. Akar
    Gurler, O.
    Ozmutlu, E. N.
    Yalcin, S.
    ANNALS OF NUCLEAR ENERGY, 2013, 58 : 198 - 201
  • [43] Comparative study of mass attenuation coefficients for LDPE/metal oxide composites by Monte Carlo simulations
    Alavian, Hoda
    Tavakoli-Anbaran, Hossein
    EUROPEAN PHYSICAL JOURNAL PLUS, 2020, 135 (01):
  • [44] Dose Determination in a CT Control Room Using TLD and Monte-Carlo-Method-Based FLUKA Code
    Yesil, A. H.
    Aksu, M. G.
    Cecen, Y.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S772 - S772
  • [45] Comparative study of mass attenuation coefficients for LDPE/metal oxide composites by Monte Carlo simulations
    Hoda Alavian
    Hossein Tavakoli-Anbaran
    The European Physical Journal Plus, 135
  • [46] Calculation of gamma-ray mass attenuation coefficients of some Egyptian soil samples using Monte Carlo methods
    Medhat, M. E.
    Demir, Nilgun
    Tarim, Urkiye Akar
    Gurler, Orhan
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2014, 169 (08): : 706 - 714
  • [47] A new method to calculate the response of the WENDI-II rem counter using the FLUKA Monte Carlo Code
    Jaegerhofer, Lukas
    Feldbaumer, Eduard
    Theis, Christian
    Roesler, Stefan
    Vincke, Helmut
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 691 : 81 - 85
  • [48] Dosimetry studies for an optimized reloading of a panoramic Cobalt-60 source using FLUKA Monte Carlo code
    Hammami, Imen
    Bouabidi, Ammar
    Ayadi, Asma
    Ounalli, Leila
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [49] Determination of mass attenuation coefficient for some polymers using Monte Carlo simulation
    Singh, V. P.
    Shirmardi, S. P.
    Medhat, M. E.
    Badiger, N. M.
    VACUUM, 2015, 119 : 284 - 288
  • [50] A comparison based on the calculation of some hadron doses in addition to the secondary neutron fluence using the FLUKA Monte Carlo code
    Yjjou M.
    Dekhissi H.
    Derkaoui J.E.
    Didi A.
    Aknouch A.
    International Journal of Nuclear Energy Science and Technology, 2020, 14 (04) : 302 - 309