Dosimetry studies for an optimized reloading of a panoramic Cobalt-60 source using FLUKA Monte Carlo code

被引:0
|
作者
Hammami, Imen [1 ,2 ]
Bouabidi, Ammar [1 ,2 ,3 ]
Ayadi, Asma [1 ,2 ]
Ounalli, Leila [1 ,2 ]
机构
[1] Tunisian Ctr Nucl Sci & Technol, Technopark Sidi Thabet, Sidi Thabet, Tunisia
[2] Minist Higher Educ & Res, Res Lab Energy & Matter Nucl Sci Dev LR16CNSTN02, Tunis, Tunisia
[3] Univ Tunis Manar, Fac Sci Tunis, Tunis 2092, Tunisia
关键词
Reload; Cobalt-60; Monte Carlo; FLUKA; Dose rate; Uniformity; PREDICTIVE TOOL;
D O I
10.1016/j.nima.2024.169417
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Cobalt-60 source used at the Tunisian Gamma Irradiation Facility is nearing the end of its useful life. Due to the current low dose rates, the irradiation process takes a long time. To address exposure time and cost issues, source racks need to be reloaded to improve the quality of the exposure process. This work aims to find the optimal new configuration for future reloading of the Cobalt-60 source rack and to evaluate the dose rate distribution in the vicinity of the Irradiator and the Dose Uniformity Ratio (DUR) in a dummy product. When keeping old pencils, the optimal configuration will need to be adjusted to accommodate the new Cobalt-60 pencils. The replenishment method developed using FLUKA-based Monte Carlo code involved the addition of six new pencils: three in the upper top (outer) holder of the source rack and three in the lower bottom (inner) source holder. The spatial distribution of dose rates in the vicinity of the source rack before and after reloading was evaluated. For the radiation processing, the maximum and minimum absorbed dose in the dummy product were estimated to calculate the DUR value. The DUR value for a single-use medical product is about 2.5. The results obtained before and after reloading show that the spatial distribution of the dose rate is uniform for the proposed configurations, and has a value of approximately 0.4 kGy/h after reloading at the conveyor belt location.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Monte Carlo dosimetry for BEBIG Cobalt-60 brachytherapy source with gynecological applicator in the presence of inhomogeneities
    Moradi, Farhad
    Sani, Siti Fairus Abdul
    Mahyuddin, Azman
    Ung, Ngie Min
    Bradley, David Andrew
    Almugren, Kholoud
    Rashid, Hairul Azhar Abdul
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2024, 30 (03): : 145 - 151
  • [2] Monte Carlo dosimetry for a new 32P brachytherapy source using FLUKA code
    Rajabi, Razieh
    Taherparvar, Payvand
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (01) : 76 - 90
  • [3] Simulation of cobalt-60 production in research reactors using OpenMC Monte Carlo code
    Judaibi, Abdulrahim
    Soliman, Abdelfattah Y.
    KERNTECHNIK, 2022, 87 (02) : 230 - 236
  • [4] DOSIMETRY OF A KILOCURIE COBALT-60 SOURCE
    DAVISON, S
    GOLDBLITH, SA
    PROCTOR, BE
    KAREL, M
    KAN, B
    BATES, CJ
    NUCLEONICS, 1953, 11 (07): : 22 - 26
  • [5] STUDIES ON THE DOSIMETRY AND BACTERICIDAL EFFECTS OF GAMMA RADIATIONS FROM A COBALT-60 SOURCE
    GOLDBLITH, SA
    PROCTOR, BE
    DAVISON, S
    LANG, DA
    KAN, B
    BATES, CJ
    KAREL, M
    RADIOLOGY, 1953, 60 (05) : 732 - 736
  • [6] Combining Monte Carlo simulations and dosimetry measurements for process control in the Tunisian Cobalt-60 irradiator after three half lives of the source
    Ounalli, Leila
    Bhar, Maroua
    Mejri, Arbi
    Manai, Kais
    Bouabidi, Ammar
    Abdallah, Shayma Mohamed
    Reguigui, Nafaa
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (09)
  • [7] Combining Monte Carlo simulations and dosimetry measurements for process control in the Tunisian Cobalt-60 irradiator after three half lives of the source
    Leila Ounalli
    Maroua Bhar
    Arbi Mejri
    Kais Manai
    Ammar Bouabidi
    Shayma Mohamed Abdallah
    Nafaa Reguigui
    Nuclear Science and Techniques, 2017, 28
  • [8] RADIATION PROTECTION STUDIES FOR MEDICAL PARTICLE ACCELERATORS USING FLUKA MONTE CARLO CODE
    Infantino, Angelo
    Cicoria, Gianfranco
    Lucconi, Giulia
    Pancaldi, Davide
    Vichi, Sara
    Zagni, Federico
    Mostacci, Domiziano
    Marengo, Mario
    RADIATION PROTECTION DOSIMETRY, 2017, 173 (1-3) : 185 - 191
  • [9] MICRODOSIMETRIC SIMULATIONS OF CARBON IONS USING THE MONTE CARLO CODE FLUKA
    Chiriotti, S.
    Conte, V.
    Colautti, P.
    Selva, A.
    Mairani, A.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 187 - 191
  • [10] FLUKA Monte Carlo Simulation Code As Used for Radiation Studies in the Alice Experiment
    Pastircak, B.