Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit

被引:5
|
作者
Kim, Dae-Hyun [1 ,2 ,3 ]
Kang, Young Nam [1 ]
Suh, Tae-Suk [2 ,3 ]
Shin, Jungwook [4 ]
Kim, Jong Won [5 ]
Yoo, Seung Hoon [6 ]
Park, Seyjoon [7 ]
Lee, Sang Hoon [7 ]
Cho, Sungkoo [7 ]
Shin, Dongho [7 ]
Kim, Dae Yong [7 ]
Lee, Se Byeong [7 ]
机构
[1] Catholic Univ Korea, Dept Radiat Oncol, Seoul St Marys Hosp, Coll Med, Seoul 137701, South Korea
[2] Catholic Univ Korea, Dept Biomed Engn, Coll Med, Seoul 137701, South Korea
[3] Catholic Univ Korea, Res Inst Biomed Engn, Coll Med, Seoul 137701, South Korea
[4] Univ Calif San Francisco, Helen Diller Family Comprehens Canc Ctr, Dept Radiat Oncol, San Francisco, CA 94143 USA
[5] Kwandong Univ, Dept Radiat Oncol, Myongji Hosp, Coll Med, Goyang 412270, South Korea
[6] CHA Univ, CHA Bundang Med Cente, Dept Radiat Oncol, Songnam 463712, South Korea
[7] Natl Canc Ctr, Proton Therapy Ctr, Goyang 410769, South Korea
基金
新加坡国家研究基金会;
关键词
Commissioning; Geant4; Monte Carlo simulation; Proton therapy; Validation; BEAM DELIVERY-SYSTEM; DOSE CALCULATION; SIMULATION; IMPLEMENTATION; SPACE;
D O I
10.3938/jkps.61.1125
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Modern commercial treatment planning systems for proton therapy use the pencil beam algorithm for calculating the absorbed dose. Although it is acceptable for clinical radiation treatment, the accuracy of this method is limited. Alternatively, the Monte Carlo method, which is relatively accurate in dose calculations, has been applied recently to proton therapy. To reduce the remaining uncertainty in proton therapy dose calculations, in the present study, we employed Monte Carlo simulations and the Geant4 simulation toolkit to develop a model for a of a proton treatment nozzle. The results from a Geant4-based medical application of the proton treatment nozzle were compared to the measured data. Simulations of the percentage depth dose profiles showed very good agreement within 1 mm in distal range and 3 mm in modulated width. Moreover, the lateral dose profiles showed good agreement within 3% in the central region of the field and within 10% in the penumbra regions. In this work, we proved that the Geant4 Monte Carlo model of a proton treatment nozzle could be used to the calculate proton dose distributions accurately.
引用
收藏
页码:1125 / 1130
页数:6
相关论文
共 50 条
  • [41] A framework for Monte Carlo simulation calculations in GEANT4
    Walker, B.
    Figgins, J.
    Comfort, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (02): : 889 - 895
  • [42] Preliminary test of Bragg application for proton therapy using the Geant4 toolkit
    Loffredo, Filomena
    Pugliese, Mariagabriella
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2018, 41 (06):
  • [43] Fano Cavity Test of the Monte Carlo Codes GEANT4 and PENH for Proton Transport
    Sterpin, E.
    Sorriaux, J.
    Vynckier, S.
    Bouchard, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [44] Geant4 Monte Carlo simulations for the LPCTrap setup
    D. Rodríguez
    G. Ban
    D. Durand
    F. Duval
    X. Fléchard
    E. Liénard
    F. Mauger
    A. Méry
    O. Naviliat-Cuncic
    J. -C. Thomas
    Ph. Velten
    The European Physical Journal A, 2009, 42 : 397 - 400
  • [45] Analytical and Monte-Carlo (GEANT4) calculations of collimator scatter of proton beams
    Ulmer, W.
    Schaffner, B.
    MEDICAL PHYSICS, 2007, 34 (06) : 2419 - 2419
  • [46] Treatment planning of proton beams using the GEANT Monte Carlo
    Ragona, R
    Rolando, V
    Solano, A
    ADVANCES IN HADRONTHERAPY, 1997, 1144 : 304 - 308
  • [47] An overview of the Geant4 toolkit
    Apostolakis, John
    Wright, Dennis H.
    HADRONIC SHOWER SIMULATION WORKSHOP, 2007, 896 : 1 - +
  • [48] Using Geant4 Monte Carlo toolkit to evaluate a low power X-ray tube generator configuration
    Hoff, G.
    Streck, E. E.
    Lai, A.
    Fanti, V
    Golosio, B.
    Nascimento, C. D.
    Souza, E. G.
    APPLIED RADIATION AND ISOTOPES, 2021, 168
  • [49] NUMERICAL SIMULATION OF PROTON BACKSCATTERING SPECTRA IN GEANT4 TOOLKIT
    Lingis, D.
    Gaspariunas, M.
    Kovalevskij, V.
    Plukis, A.
    Remeikis, V.
    LITHUANIAN JOURNAL OF PHYSICS, 2024, 64 (01): : 48 - 57
  • [50] A GATE/Geant4 Monte Carlo toolkit for surface dose calculation in VMAT breast cancer radiotherapy
    Arbor, Nicolas
    Gasteuil, Jean
    Noblet, Caroline
    Moreau, Matthieu
    Meyer, Philippe
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 61 : 112 - 117