Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit

被引:5
|
作者
Kim, Dae-Hyun [1 ,2 ,3 ]
Kang, Young Nam [1 ]
Suh, Tae-Suk [2 ,3 ]
Shin, Jungwook [4 ]
Kim, Jong Won [5 ]
Yoo, Seung Hoon [6 ]
Park, Seyjoon [7 ]
Lee, Sang Hoon [7 ]
Cho, Sungkoo [7 ]
Shin, Dongho [7 ]
Kim, Dae Yong [7 ]
Lee, Se Byeong [7 ]
机构
[1] Catholic Univ Korea, Dept Radiat Oncol, Seoul St Marys Hosp, Coll Med, Seoul 137701, South Korea
[2] Catholic Univ Korea, Dept Biomed Engn, Coll Med, Seoul 137701, South Korea
[3] Catholic Univ Korea, Res Inst Biomed Engn, Coll Med, Seoul 137701, South Korea
[4] Univ Calif San Francisco, Helen Diller Family Comprehens Canc Ctr, Dept Radiat Oncol, San Francisco, CA 94143 USA
[5] Kwandong Univ, Dept Radiat Oncol, Myongji Hosp, Coll Med, Goyang 412270, South Korea
[6] CHA Univ, CHA Bundang Med Cente, Dept Radiat Oncol, Songnam 463712, South Korea
[7] Natl Canc Ctr, Proton Therapy Ctr, Goyang 410769, South Korea
基金
新加坡国家研究基金会;
关键词
Commissioning; Geant4; Monte Carlo simulation; Proton therapy; Validation; BEAM DELIVERY-SYSTEM; DOSE CALCULATION; SIMULATION; IMPLEMENTATION; SPACE;
D O I
10.3938/jkps.61.1125
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Modern commercial treatment planning systems for proton therapy use the pencil beam algorithm for calculating the absorbed dose. Although it is acceptable for clinical radiation treatment, the accuracy of this method is limited. Alternatively, the Monte Carlo method, which is relatively accurate in dose calculations, has been applied recently to proton therapy. To reduce the remaining uncertainty in proton therapy dose calculations, in the present study, we employed Monte Carlo simulations and the Geant4 simulation toolkit to develop a model for a of a proton treatment nozzle. The results from a Geant4-based medical application of the proton treatment nozzle were compared to the measured data. Simulations of the percentage depth dose profiles showed very good agreement within 1 mm in distal range and 3 mm in modulated width. Moreover, the lateral dose profiles showed good agreement within 3% in the central region of the field and within 10% in the penumbra regions. In this work, we proved that the Geant4 Monte Carlo model of a proton treatment nozzle could be used to the calculate proton dose distributions accurately.
引用
收藏
页码:1125 / 1130
页数:6
相关论文
共 50 条
  • [1] Monte Carlo modeling and validation of a proton treatment nozzle by using the Geant4 toolkit
    Dae-Hyun Kim
    Young Nam Kang
    Tae-Suk Suh
    Jungwook Shin
    Jong Won Kim
    Seung Hoon Yoo
    Seyjoon Park
    Sang Hoon Lee
    Sungkoo Cho
    Dongho Shin
    Dae Yong Kim
    Se Byeong Lee
    Journal of the Korean Physical Society, 2012, 61 : 1125 - 1130
  • [2] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit
    Freudenberg, Robert
    Kotzerke, Jorg
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1488 - 1489
  • [3] Proton Source Modeling for Geant4 Monte Carlo Simulations
    Barnes, S.
    McAuley, G.
    Wroe, A.
    Slater, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3756 - 3757
  • [4] Cellular Dosimetry Using the Geant4 Monte Carlo Toolkit REPLY
    Cai, Zhongli
    Pignol, Jean-Philippe
    Chan, Conrad
    Reilly, Raymond M.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1489 - 1489
  • [5] Verification and Validation of the Geant4 Monte Carlo Code Toolkit for DEMO TBR Evaluations
    Nunnenmann, Elena
    Fischer, Ulrich
    Serikov, Arkady
    FUSION ENGINEERING AND DESIGN, 2020, 161
  • [6] Applications of the Monte Carlo method in nuclear physics using the GEANT4 toolkit
    Moralles, Mauricio
    Guimaraes, Carla C.
    Bonifacio, Daniel A. B.
    Okuno, Emico
    Murata, Helio M.
    Bottaro, Marcio
    Menezes, Mario O.
    Guimaraes, Valdir
    NUCLEAR PHYSICS 2008: XXXI WORKSHOP ON NUCLEAR PHYSICS IN BRAZIL, 2009, 1139 : 51 - +
  • [7] Calculation of surface spectral irradiance using the Geant4 Monte Carlo toolkit
    Boudjella, Manal Yasmine
    Belbachir, Ahmed Hafid
    Dib, Samy Anis Amine
    Meftah, Mustapha
    JOURNAL OF ATMOSPHERIC AND SOLAR-TERRESTRIAL PHYSICS, 2023, 248
  • [8] Monte Carlo simulations in proton dosimetry with Geant4
    Moravek, Z
    Bogner, L
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S62 - S62
  • [9] Validation of GEANT4, an object-oriented Monte Carlo toolkit, for simulations in medical physics
    Carrier, JF
    Archambault, L
    Beaulieu, L
    Roy, R
    MEDICAL PHYSICS, 2004, 31 (03) : 484 - 492
  • [10] Optimization of an ultra-fast silicon detector for proton and carbon beams using GEANT4 Monte Carlo toolkit
    Mashayekhi, Mohsen
    Mowlavi, Ali Asghar
    Jia, Sayyed Bijan
    Ghayoumizadeh, Hossein