β-lactoglobulin denaturation, aggregation, and fouling in a plate heat exchanger: Pilot-scale experiments and dimensional analysis

被引:50
|
作者
Petit, Jeremy [1 ]
Six, Thierry [1 ]
Moreau, Anne [1 ]
Ronse, Gilles [1 ]
Delaplace, Guillaume [1 ]
机构
[1] INRA, Proc Interfaceset & Hyg Mat UR638, F-59651 Villeneuve Dascq, France
关键词
Dimensional analysis; Mathematical modelling; Food processing; Kinetics; Denaturation/aggregation; Fouling; STAINLESS-STEEL SURFACES; WHEY-PROTEIN; ALPHA-LACTALBUMIN; MILK; TEMPERATURE; MODEL; ADSORPTION; KINETICS; DEPOSITS; BEHAVIOR;
D O I
10.1016/j.ces.2013.06.045
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this work, we investigated the role of four independent process parameters, namely product temperature at the heat exchanger outlet, mean residence time, temperature increase between the heat exchanger inlet and outlet, and heat effectiveness, in the protein denaturation, aggregation, and fouling of a beta-lactoglobulin (beta-lg) concentrate that was chosen as model fluid for milk derivatives. A pilot scale plate heat exchanger in countercurrent configuration, supplied with a holder, was used in order to mimic industrial process conditions. The denaturation level and aggregates size of the heat treated beta-lg concentrate at the exchanger and holder outlets, along with the fouling mass in the plate heat exchanger were simultaneously determined. The results indicated that beta-lg denaturation, aggregation, and fouling reactions were mainly governed by the temperature profile in the investigated range of operating conditions, even though a small influence of residence time and healing rate was highlighted in the less denaturing conditions. A dimensional analysis was performed to identify the key dimensionless numbers governing beta-lg denaturation, aggregation, and fouling mechanisms in the heat treatment of a beta-lg concentrate. This allowed to emphasise the major influence of the Arrhenius exponential factor of beta-lg unfolding reaction, both related to temperature and beta-lg reactivity. The first Damkohler and Reynolds numbers, related to residence time and hydrodynamic conditions in the heat exchanger, as well as the heat exchange process parameters, linked to the heat effectiveness and the bulk-wall temperature differences, had also a small impact on beta-lg chemical behaviour. Moreover, empirical relationships based only on the Arrhenius exponential factor of beta-lg unfolding reaction permitted to describe the main trends observed in denaturation levels, aggregate sizes, and fouling masses, which underlined the predominant role of temperature and beta-lg reactivity in the investigated operating conditions. This study outlines finally that fast heat treatments permit to minimise fouling issues. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:432 / 450
页数:19
相关论文
共 44 条
  • [31] Analysis of local fouling in a pilot-scale submerged hollow-fiber membrane system for drinking water treatment by membrane autopsy
    Lee, Mooseok
    Kim, Jeonghwan
    SEPARATION AND PURIFICATION TECHNOLOGY, 2012, 95 : 227 - 234
  • [32] Heat Flux Analysis and Assessment of Drying Kinetics during Lyophilization of Fruits in a Pilot-Scale Freeze Dryer
    Sedmak, Ivan
    Moze, Matic
    Kambic, Gorazd
    Golobic, Iztok
    FOODS, 2023, 12 (18)
  • [33] Reactive distillation for sustainable synthesis of bio-ethyl lactate: Kinetics, pilot-scale experiments and process analysis
    Ding, Qiuyan
    Li, Hong
    Liang, Zhanpeng
    Zuo, Rui
    Huang, Songzhe
    Li, Xingang
    Jiao, Yilai
    Gao, Xin
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2022, 179 : 388 - 400
  • [34] Reactive distillation for sustainable synthesis of bio-ethyl lactate: Kinetics, pilot-scale experiments and process analysis
    Ding, Qiuyan
    Li, Hong
    Liang, Zhanpeng
    Zuo, Rui
    Huang, Songzhe
    Li, Xingang
    Jiao, Yilai
    Gao, Xin
    Chemical Engineering Research and Design, 2022, 179 : 388 - 400
  • [35] Development of Nusselt number correlation using dimensional analysis for plate heat exchanger with a carboxymethyl cellulose solution
    Muthamizhi, Karuppannan
    Kalaichelvi, Ponnusamy
    HEAT AND MASS TRANSFER, 2015, 51 (06) : 815 - 823
  • [36] Development of Nusselt number correlation using dimensional analysis for plate heat exchanger with a carboxymethyl cellulose solution
    Karuppannan Muthamizhi
    Ponnusamy Kalaichelvi
    Heat and Mass Transfer, 2015, 51 : 815 - 823
  • [37] Insight into fouling potential analysis of a pilot-scale pressure-assisted forward osmosis plant for diluted seawater reverse osmosis desalination
    Kim, Dong-Ho
    Lee, Chulmin
    Nguyen, Thanh-Tin
    Adha, Rusnang Syamsul
    Kim, Chaeyeon
    Ahn, Sang-Jun
    Son, Heejong
    Kim, In S.
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2021, 98 : 237 - 246
  • [38] Newly developed membrane contactor-based N and P recovery process: Pilot-scale field experiments and cost analysis
    Uzkurt Kaljunen, Juho
    Al-Juboori, Raed A.
    Mikola, Anna
    Righetto, Ilaria
    Konola, Irene
    Journal of Cleaner Production, 2021, 281
  • [39] Heat transfer performance of a plate-finned tube heat exchanger - A three-dimensional steady numerical analysis for a single row tube
    Onishi, H
    Inaoka, K
    Suzuki, K
    Matsubara, K
    HEAT TRANSFER 1998, VOL 6: GENERAL PAPERS, 1998, : 227 - 232
  • [40] Synthesis of dimethyl carbonate and propylene glycol in a membrane-assisted reactive distillation process: Pilot-scale experiments, modeling and process analysis
    Holtbruegge, Johannes
    Wierschem, Matthias
    Lutze, Philip
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2014, 84 : 54 - 70