β-lactoglobulin denaturation, aggregation, and fouling in a plate heat exchanger: Pilot-scale experiments and dimensional analysis

被引:50
|
作者
Petit, Jeremy [1 ]
Six, Thierry [1 ]
Moreau, Anne [1 ]
Ronse, Gilles [1 ]
Delaplace, Guillaume [1 ]
机构
[1] INRA, Proc Interfaceset & Hyg Mat UR638, F-59651 Villeneuve Dascq, France
关键词
Dimensional analysis; Mathematical modelling; Food processing; Kinetics; Denaturation/aggregation; Fouling; STAINLESS-STEEL SURFACES; WHEY-PROTEIN; ALPHA-LACTALBUMIN; MILK; TEMPERATURE; MODEL; ADSORPTION; KINETICS; DEPOSITS; BEHAVIOR;
D O I
10.1016/j.ces.2013.06.045
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this work, we investigated the role of four independent process parameters, namely product temperature at the heat exchanger outlet, mean residence time, temperature increase between the heat exchanger inlet and outlet, and heat effectiveness, in the protein denaturation, aggregation, and fouling of a beta-lactoglobulin (beta-lg) concentrate that was chosen as model fluid for milk derivatives. A pilot scale plate heat exchanger in countercurrent configuration, supplied with a holder, was used in order to mimic industrial process conditions. The denaturation level and aggregates size of the heat treated beta-lg concentrate at the exchanger and holder outlets, along with the fouling mass in the plate heat exchanger were simultaneously determined. The results indicated that beta-lg denaturation, aggregation, and fouling reactions were mainly governed by the temperature profile in the investigated range of operating conditions, even though a small influence of residence time and healing rate was highlighted in the less denaturing conditions. A dimensional analysis was performed to identify the key dimensionless numbers governing beta-lg denaturation, aggregation, and fouling mechanisms in the heat treatment of a beta-lg concentrate. This allowed to emphasise the major influence of the Arrhenius exponential factor of beta-lg unfolding reaction, both related to temperature and beta-lg reactivity. The first Damkohler and Reynolds numbers, related to residence time and hydrodynamic conditions in the heat exchanger, as well as the heat exchange process parameters, linked to the heat effectiveness and the bulk-wall temperature differences, had also a small impact on beta-lg chemical behaviour. Moreover, empirical relationships based only on the Arrhenius exponential factor of beta-lg unfolding reaction permitted to describe the main trends observed in denaturation levels, aggregate sizes, and fouling masses, which underlined the predominant role of temperature and beta-lg reactivity in the investigated operating conditions. This study outlines finally that fast heat treatments permit to minimise fouling issues. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:432 / 450
页数:19
相关论文
共 44 条
  • [21] EXPERIMENTAL STUDY ON THE HEAT TRANSFER PERFORMANCE OF THE DIFFUSION-BONDED MICRO CHANNEL HEAT EXCHANGER IN THE PILOT-SCALE TEST FACILITY
    Yoon, Seok Ho
    Oh, Dong-Wook
    Kim, Young
    Choi, Jun Seok
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2013, VOL 8B, 2014,
  • [22] Coagulation optimization for DOC removal: pilot-scale analysis of UF fouling and disinfection byproduct formation potential
    Wray, Heather E.
    Andrews, Robert C.
    Berube, Pierre R.
    WATER SCIENCE AND TECHNOLOGY-WATER SUPPLY, 2016, 16 (02): : 473 - 480
  • [23] A risk-based performance analysis of plate-and-frame heat exchangers subject to fouling: Economics of heat exchanger cleaning
    Khan, JUR
    Zubair, SM
    HEAT TRANSFER ENGINEERING, 2004, 25 (06) : 87 - 100
  • [24] Pilot-scale investigation of drinking water ultrafiltration membrane fouling rates using advanced data analysis techniques
    Chen, Fei
    Peldszus, Sigrid
    Peiris, Ramila H.
    Ruhl, Aki S.
    Mehrez, Renata
    Jekel, Martin
    Legge, Raymond L.
    Huck, Peter M.
    WATER RESEARCH, 2014, 48 : 508 - 518
  • [25] Analysis of membrane fouling in a pilot-scale microfiltration plant using mathematical model and artificial neural network model
    Park, Younjong
    Choi, Yongjun
    Lee, Sangho
    DESALINATION AND WATER TREATMENT, 2017, 77 : 69 - 74
  • [26] A reaction engineering approach to the analysis of fouling by whey proteins of a six-channels-per-pass plate heat exchanger
    Delplace, F
    Leuliet, JC
    Levieux, D
    JOURNAL OF FOOD ENGINEERING, 1997, 34 (01) : 91 - 108
  • [27] A VIBROFLUIDIZED-BED HEAT-EXCHANGER FOR HEAT-RECOVERY FROM A HOT GAS .1. FEASIBILITY STUDY OF A PILOT-SCALE SYSTEM
    CHEAH, CW
    HIRT, DE
    LIU, YA
    SQUIRES, AM
    POWDER TECHNOLOGY, 1988, 55 (04) : 257 - 267
  • [28] A VIBROFLUIDIZED-BED HEAT-EXCHANGER FOR HEAT-RECOVERY FROM A HOT GAS .2. HEAT-TRANSFER EVALUATION OF A PILOT-SCALE SYSTEM
    CHEAH, CW
    HIRT, DE
    LIU, YA
    SQUIRES, AM
    POWDER TECHNOLOGY, 1988, 55 (04) : 269 - 276
  • [29] HIGH TEMPERATURE INDUSTRIAL-SCALE CO2 HEAT PUMPS: THERMODYNAMIC ANALYSIS AND PILOT-SCALE TESTING
    Heid, Timothy J.
    Miller, Jason D.
    Mallinak, Jason A.
    Magyar, Luke
    PROCEEDINGS OF ASME TURBO EXPO 2024: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, GT2024, VOL 11, 2024,
  • [30] Ash fouling characteristic analysis and prediction for pillow plate heat exchanger in waste heat recovery based on attentive-feature decision algorithm
    Yang, Qi
    Tong, Shuiguang
    Tong, Zheming
    Wang, Haidan
    Cao, Xiangkun Elvis
    FUEL, 2024, 372