Low-profile Zenith Alpha™ Thoracic Stent Graft Modification Using Preloaded Wires for Urgent Repair of Thoracoabdominal and Pararenal Abdominal Aortic Aneurysms

被引:26
|
作者
Han, Sukgu M. [1 ]
Tenorio, Emanuel R. [2 ]
Mirza, Aleem K. [2 ]
Zhang, Louis [1 ]
Weiss, Salome [2 ,3 ]
Oderich, Gustavo S. [2 ]
机构
[1] Univ Southern Calif, Div Vasc Surg & Endovasc Therapy, Los Angeles, CA 90007 USA
[2] Mayo Clin, Div Vasc & Endovasc Surg, Rochester, MN USA
[3] Univ Bern, Dept Cardiovasc Surg, Inselspital, Bern, Switzerland
关键词
MODIFIED ENDOVASCULAR GRAFTS; REPORTING STANDARDS; OUTCOMES;
D O I
10.1016/j.avsg.2020.02.022
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The aim of this study is to describe a modification technique using the low-profile Cook Zenith AlphaTM thoracic stent graft, and addition of a preloaded wire system, for urgent repair of pararenal (PRA) and thoracoabdominal (TAAA) aortic aneurysms. Methods: We analyzed 20 consecutive patients who underwent urgent physician modified endograft repair (PMEG) of PRA and TAAA at 2 institutions. The low-profile Cook Zenith Alpha Thoracic stent graft was modified in accordance with each specific patient anatomic character-istics. End points were technical success, 30-day mortality, and major adverse events (MAEs). Results: Technical success was achieved in all patients (100%). A total of 76 renal-mesenteric arteries were incorporated by fenestrations (70%) or directional branches (30%) with an average of 3.7 +/- 0.6 vessels per patient. There were 6 different types of stent configuration. The most common design consisted of 4 fenestrations (9 patients, 45%). The average of modification time was 110 +/- 27 minutes. Total procedure time (including the time for open component) was 242 +/- 75 minutes. There was no death within the first 30 days or hospital stay. MAEs occurred in 10 patients (50%). The most common MAEs were acute kidney injury (by Risk, Injury, and Failure; and Loss; and End-stage kidney disease criteria) in 6 patients (30%), esti-mated blood loss >1 L, respiratory failure requiring reintubation in 2 patients (10%) each, and paraplegia and ischemic colitis in 1 patient (5%) each. One patient (5%) required temporary, new-onset dialysis. Conclusions: PMEG using low-profile Zenith Alpha thoracic stent graft was safe with no early mortality and acceptable early morbidity.
引用
收藏
页码:14 / 25
页数:12
相关论文
共 50 条
  • [31] Outcomes of low- and standard-profile fenestrated and branched stent grafts for treatment of complex abdominal and thoracoabdominal aortic aneurysms
    Dias-Neto, Marina
    Tenorio, Emanuel R.
    Lima, Guilherme B. Barbosa
    Baghbani-Oskouei, Aidin
    Saqib, Naveed
    Mendes, Bernardo C.
    Mirza, Aleem K.
    Oderich, Gustavo S.
    JOURNAL OF VASCULAR SURGERY, 2022, 76 (05) : 1160 - +
  • [32] Prospective Multicenter Study of the Low-Profile Relay Stent-Graft in Patients with Thoracic Aortic Disease: The Regeneration Study
    Riambau, Vicenc
    Giudice, Rocco
    Trabattoni, Piero
    Llagostera, Secundino
    Fadda, Gianfranco
    Lenti, Massimo
    Garcia, Ivan
    Maeso, Jordi
    Blanco, Carla
    Verzini, Fabio
    ANNALS OF VASCULAR SURGERY, 2019, 58 : 180 - 189
  • [33] Staged Hybrid Repair of Combined Ascending/Descending Thoracic Aortic Aneurysms Using the Frozen Elephant Trunk Technique With the Cook Zenith Tx2 Stent Graft
    Melikian, Vicken
    Pellegrini, Daniel
    Hua, Hong T.
    JOURNAL OF VASCULAR SURGERY, 2014, 60 (02) : 545 - 546
  • [34] Long-term outcome and reintervention after endovascular abdominal aortic aneurysm repair using the Zenith stent graft - Discussion
    Quinones-Baldrich, William
    Hiramoto, Jade
    Starnes, Benjamin
    JOURNAL OF VASCULAR SURGERY, 2007, 45 (03) : 465 - 466
  • [35] Endovascular Repair of Abdominal Aortic Aneurysms With Reverse Taper Neck Anatomy Using the Endurant Stent-Graft: Analysis of Stent-Graft Oversizing
    Mwipatayi, Bibombe P.
    Picardo, Alarick
    Wong, Jackie
    Thomas, Shannon D.
    Vijayan, Vikram
    JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (04) : 514 - 522
  • [36] Technical video of endovascular repair of chronic postdissection thoracoabdominal aortic aneurysm using a five-vessel preloaded fenestrated-branched stent graft
    Mirza, Aleem K.
    Tenorio, Emanuel R.
    Karkkainen, Jussi M.
    Ozbek, Pinar
    Oderich, Gustavo S.
    JOURNAL OF VASCULAR SURGERY, 2019, 69 (01) : 296 - +
  • [37] Total Endovascular Repair of Complex Thoracoabdominal/Abdominal Aortic Aneurysms with a Four-Branched Off-the-Shelf G-Branch™ Stent Graft
    Guo, Wei
    He, Yuan
    Zhang, Hongpeng
    Wei, Ren
    Jia, Senhao
    Liu, Jie
    ANNALS OF VASCULAR SURGERY, 2021, 71 : 534.e7 - 534.e12
  • [39] Staged thoracic and abdominal aortic aneurysm repair using stent graft technology and surgery in a patient with acute renal failure
    Eton, D
    Terramani, TT
    Katz, M
    ANNALS OF VASCULAR SURGERY, 2000, 14 (02) : 114 - 117
  • [40] Safety and efficacy of physician-modified thoracic endovascular aortic repair using a low-profile device for aortic arch lesions
    Hashizume, Kenichi
    Mori, Mitsuharu
    Yagami, Toshiaki
    Takaki, Hidenobu
    Matsuoka, Tadashi
    Nara, Tsutomu
    Nishida, Mayu
    Shimizu, Hideyuki
    ASIAN CARDIOVASCULAR & THORACIC ANNALS, 2023, 31 (04): : 340 - 347