Prospective Multicenter Study of the Low-Profile Relay Stent-Graft in Patients with Thoracic Aortic Disease: The Regeneration Study

被引:15
|
作者
Riambau, Vicenc [1 ]
Giudice, Rocco [2 ]
Trabattoni, Piero [3 ]
Llagostera, Secundino [4 ]
Fadda, Gianfranco [5 ]
Lenti, Massimo [6 ]
Garcia, Ivan [7 ]
Maeso, Jordi [8 ]
Blanco, Carla [1 ]
Verzini, Fabio [9 ]
机构
[1] Hosp Clin Barcelona, Barcelona, Spain
[2] Azienda Osped S Giovanni Addolorata, Rome, Italy
[3] Ctr Cardiol Monzino IRCCS, Milan, Italy
[4] Hosp Badalona Germans Trias & Pujol, Badalona, Spain
[5] Osped San Francesco, Nuoro, Italy
[6] Azienda Osped Perugia, Perugia, Italy
[7] Hosp Univ Marques de Valdecilla, Santander, Spain
[8] Hosp Univ Vall dHebron, Barcelona, Spain
[9] Univ Torino, Turin, Italy
关键词
ENDOVASCULAR PROCEDURES; REPORTING STANDARDS; REPAIR TEVAR; COMPLICATIONS; ACCESS; SYSTEM; METAANALYSIS; STATEMENT; OUTCOMES; SURGERY;
D O I
10.1016/j.avsg.2018.10.017
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: To evaluate the early safety and clinical performance of the new low-profile RelayPro Thoracic Stent-Graft System in patients with thoracic aortic disease. Methods: This was an international, prospective, single-arm study in patients diagnosed with thoracic aorta disease (aneurysm, pseudoaneurysm, dissection, penetrating atherosclerotic ulcer, or intramural hematoma) and treated with a RelayPro stent-graft (in bare stent and/or nonbare stent configurations). The primary endpoints were freedom from aneurysm or dissectionrelated mortality and stent-graft performance. Results: A total of 31 patients were treated with the RelayPro thoracic stent-graft between 2014 and 2015 at 8 sites in Italy and Spain. Mean age was 72.1 (+/- 10.2) years and 77% were male, 74% with hypertension, and 42% with a history of smoking. Twenty-four (77%) had aneurysms (fusiform in 46%, saccular in 42%, pseudoaneurysm in 12%); 5 (16%) had penetrating atherosclerotic ulcer; and 2 (6%) had chronic Type B dissection. Mean vascular access diameter was 9.1 mm (6-13 mm); 7 patients (23%) had vascular access of 7 mm or less. Technical success was 100% (primary, 90%; assisted primary, 10%). Freedom from aneurysm/dissection-related mortality through 30 days was 100%. Freedom from device-related major adverse events through 30 days was 94%. At 1 year, there was 1 (3%) type Ib and 1 (3%) type II endoleak, 1 (3%) nonaneurysm-related late death, and 1 (3%) secondary intervention (to correct type Ib endoleak). Conclusions: The RelayPro has a 3-4 French profile reduction to allow endovascular repair of thoracic aortic disease in patients with smaller anatomies. This study shows good initial stent-graft performance and a favorable early safety profile.
引用
收藏
页码:180 / 189
页数:10
相关论文
共 50 条
  • [1] Early results of a low-profile stent-graft for thoracic endovascular aortic repair
    El Beyrouti, Hazem
    Lescan, Mario
    Doemland, Marco
    Mustafi, Migdat
    Jungmann, Florian
    Jorg, Tobias
    Halloum, Nancy
    Dorweiler, Bernhard
    PLOS ONE, 2020, 15 (11):
  • [2] New Low-Profile Zenith Alpha Stent-Graft for the Treatment of Thoracic Aortic Disease: A Real Breakthrough?
    Tolenaar, Jip L.
    de Vries, Jean Paul P. M.
    JOURNAL OF ENDOVASCULAR THERAPY, 2015, 22 (02) : 160 - 162
  • [3] Percutaneous placement of a low-profile stent-graft device for aortic dissections
    Quinn, SF
    Duke, DJ
    Baldwin, SS
    Bascom, TH
    Ruff, SJ
    Swangard, RJ
    DeHaas, DR
    Padgett, RC
    Bergin, PJ
    Lau, S
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (08) : 791 - 798
  • [4] A Single-Center Experience With Total Percutaneous Implantation of a Low-Profile Thoracic Aortic Stent-Graft
    Benfor, Bright
    Stana, Jan
    Prendes, Carlota Fernandez
    Pichlmaier, Maximilian
    Mehmedovic, Aldin
    Banafsche, Ramin
    Rantner, Barbara
    Tsilimparis, Nikolaos
    JOURNAL OF ENDOVASCULAR THERAPY, 2023, 30 (02) : 214 - 222
  • [5] Long-term Results of Thoracic Endovascular Aortic Repair Using a Low-Profile Stent-Graft
    Beropoulis, Efthymios
    Fazzini, Stefano
    Austermann, Martin
    Torsello, Giovanni B.
    Damerau, Sarah
    Torsello, Giovanni Federico
    JOURNAL OF ENDOVASCULAR THERAPY, 2021, 28 (01) : 56 - 62
  • [6] Percutaneous deployment of a low-profile bifurcated stent-graft
    Quinn, SF
    Kim, JH
    Sheley, RC
    Demlow, TA
    Zelko, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (03) : 654 - 656
  • [7] Endovascular stent-graft treatment of thoracic aortic disease
    Garzón, G
    Fernández-Velilla, M
    Martí, M
    Acitores, I
    Ybáñez, F
    Riera, L
    RADIOGRAPHICS, 2005, 25 : S229 - S245
  • [8] Midterm results of aortic diameter outcomes after thoracic stent-graft implantation for aortic dissection: A multicenter study
    Gaxotte, Virginia
    Thony, Fredric
    Rousseau, Herve
    Lions, Christophe
    Otal, Philippe
    Willoteaux, Serge
    Rodiere, Mathieu
    Negaiwi, Ziad
    Joffre, Francis
    Beregi, Jean-Paul
    JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (02) : 127 - 138
  • [9] Four years experience of thoracic aortic disease with stent-graft
    Bortone, AS
    D'Agostino, D
    De Cillis, E
    Schinosa, LD
    FRONTIERS IN CORONARY ARTERY DISEASE, 2003, : 745 - 749
  • [10] Endovascular stent-graft placement for thoracic aortic disease in Germany
    Eggebrecht, H
    Pamler, R
    Zipfel, B
    Herold, U
    Chavan, A
    Rehders, TC
    Hetzer, R
    Nienaber, CA
    Jakob, HG
    Erbel, R
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2006, 131 (14) : 730 - 734