EFFECT OF THE THICKNESS OF PAN/Au MODIFIED ELECTRODE ON BIOSENSOR SENSITIVITY

被引:1
|
作者
Dong, Bo [1 ]
Lu, Xiaofeng [1 ]
Li, Zhenyu [1 ]
Zhang, Hongnan [1 ]
Wang, Zongxin [1 ]
Wang, Ce [1 ]
Liu, Zongwen [2 ]
机构
[1] Jilin Univ, Alan G MacDiarmid Inst, Changchun 130012, Peoples R China
[2] Univ Sydney, Sch Chem & Biomol Engn, Sydney, NSW 2006, Australia
关键词
Membrane thickness; polyacrylonitrile/gold nanofibers; electrocatalytic; hydrogen peroxide reduction; GOLD NANOPARTICLES;
D O I
10.1142/S179360471250035X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A simple electrospinning method was used to control the thickness of polyacrylonitrile ( PAN)/Au modified electrode. The influence of membrane thickness to modified electrode sensitivity was discussed. In our experiment, a 20-min electrospinning time and a mass ratio of 3:1 PAN/HAuCl4 are the optimum parameters to generate the high performance PAN/Au membrane modified electrode for detecting H2O2 which has a sensitivity of 145.63 mA M-1 cm(-2)) and a wide linear range of 20 mu M-20 mM.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Fabrication of an amperometric tyramine biosensor based on immobilization of tyramine oxidase on AgNPs/l-Cys-modified Au electrode
    Bhawna Batra
    Suman Lata
    Rooma Devi
    Sandeep Yadav
    Chandra Shekhar Pundir
    Journal of Solid State Electrochemistry, 2012, 16 : 3869 - 3876
  • [42] Electrochemical biosensor employing PbS colloidal quantum dots/Au nanospheres-modified electrode for ultrasensitive glucose detection
    Yunong Zhao
    Jing Huang
    Qing Huang
    Yanbing Tao
    Ruiqin Gu
    Hua-Yao Li
    Huan Liu
    Nano Research, 2023, 16 : 4085 - 4092
  • [43] Bismuth UPD on the modified Au(111) electrode
    Thiel, K-O
    Hintze, M.
    Vollmer, A.
    Donner, C.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 638 (01) : 143 - 150
  • [44] THICKNESS OF ELECTRODE EFFECT LAYER
    VERMA, TS
    VARSHNEYA, NC
    JOURNAL OF ATMOSPHERIC AND TERRESTRIAL PHYSICS, 1971, 33 (07): : 975 - +
  • [45] Urea biosensor based on PANi(urease)-Nation®/Au composite electrode
    Luo, YC
    Do, JS
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (01): : 15 - 23
  • [46] A glucose biosensor using au nanoparticle modified glucose oxidase
    Meng, XW
    Ren, XL
    Tang, FQ
    NANOTECH 2003, VOL 3, 2003, : 404 - 407
  • [47] Construction of an amperometric TG biosensor based on AuPPy nanocomposite and poly (indole-5-carboxylic acid) modified Au electrode
    Narang, Jagriti
    Chauhan, Nidhi
    Rani, Poonam
    Pundir, C. S.
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2013, 36 (04) : 425 - 432
  • [48] Construction of an amperometric glycated hemoglobin biosensor based on Au-Pt bimetallic nanoparticles and poly (indole-5-carboxylic acid) modified Au electrode
    Jain, Utkarsh
    Gupta, Shaivya
    Chauhan, Nidhi
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2017, 105 : 549 - 555
  • [49] Aptamer@Au-o-phenylenediamine modified pencil graphite electrode: A new selective electrochemical impedance biosensor for the determination of insulin
    Ensafi, Ali A.
    Khoddami, Elaheh
    Rezaei, B.
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2017, 159 : 47 - 53
  • [50] Porous silicon-modified electrode for electrochemical pesticide biosensor
    Ayat, Maha
    Ayouz, Katia
    Yaddadene, Chafiaa
    Berouaken, Malika
    Gabouze, Noureddine
    JOURNAL OF COATINGS TECHNOLOGY AND RESEARCH, 2021, 18 (01) : 53 - 62