EFFECT OF THE THICKNESS OF PAN/Au MODIFIED ELECTRODE ON BIOSENSOR SENSITIVITY

被引:1
|
作者
Dong, Bo [1 ]
Lu, Xiaofeng [1 ]
Li, Zhenyu [1 ]
Zhang, Hongnan [1 ]
Wang, Zongxin [1 ]
Wang, Ce [1 ]
Liu, Zongwen [2 ]
机构
[1] Jilin Univ, Alan G MacDiarmid Inst, Changchun 130012, Peoples R China
[2] Univ Sydney, Sch Chem & Biomol Engn, Sydney, NSW 2006, Australia
关键词
Membrane thickness; polyacrylonitrile/gold nanofibers; electrocatalytic; hydrogen peroxide reduction; GOLD NANOPARTICLES;
D O I
10.1142/S179360471250035X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A simple electrospinning method was used to control the thickness of polyacrylonitrile ( PAN)/Au modified electrode. The influence of membrane thickness to modified electrode sensitivity was discussed. In our experiment, a 20-min electrospinning time and a mass ratio of 3:1 PAN/HAuCl4 are the optimum parameters to generate the high performance PAN/Au membrane modified electrode for detecting H2O2 which has a sensitivity of 145.63 mA M-1 cm(-2)) and a wide linear range of 20 mu M-20 mM.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Hybrid phenol biosensor based on modified phenoloxidase electrode
    Cabaj, Joanna
    Soloducho, Jadwiga
    Chyla, Antoni
    Jedrychowska, Agnieszka
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (01): : 225 - 231
  • [32] Laccase biosensor on monolayer-modified gold electrode
    Gupta, G
    Rajendran, V
    Atanassov, P
    ELECTROANALYSIS, 2003, 15 (20) : 1577 - 1583
  • [33] Fabrication of an amperometric tyramine biosensor based on immobilization of tyramine oxidase on AgNPs/l-Cys-modified Au electrode
    Batra, Bhawna
    Lata, Suman
    Devi, Rooma
    Yadav, Sandeep
    Pundir, Chandra Shekhar
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (12) : 3869 - 3876
  • [34] An amperometric biosensor based on laccase immobilized onto MnO2NPs/cMWCNT/PANI modified Au electrode
    Rawal, Rachna
    Chawla, Sheetal
    Malik, Poonam
    Pundir, C. S.
    INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2012, 51 (1-2) : 175 - 181
  • [35] Fabrication of a Cytochrome c Biosensor Based on Cytochrome Oxidase/NiO-NPs/cMWCNT/PANI Modified Au Electrode
    Batra, Bhawna
    Lata, Suman
    Rani, Sunita
    Pundir, C. S.
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2013, 9 (03) : 409 - 416
  • [36] Rapid Detection of Salmonella enteritidis in Pork Samples with Impedimetric Biosensor: Effect of Electrode Spacing on Sensitivity
    Kim, Giyoung
    Moon, Ji Hea
    Hahm, Bung-Kwon
    Morgan, Mark
    Bhunia, Arun
    Om, Ae Son
    FOOD SCIENCE AND BIOTECHNOLOGY, 2009, 18 (01) : 89 - 94
  • [37] Amperometric nitric oxide biosensor based on the immobilization of hemoglobin on a nanometer-sized gold colloid modified Au electrode
    Gu, HY
    Yu, AM
    Yuan, SS
    Chen, HY
    ANALYTICAL LETTERS, 2002, 35 (04) : 647 - 661
  • [38] Sensitivity improvement of a miniaturized label-free electrochemical impedance biosensor by electrode edge effect
    Kuo, Yi-Ching
    Chen, Ching-Sung
    Chang, Ku-Ning
    Lin, Chih-Ting
    Lee, Chih-Kung
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2014, 13 (03):
  • [39] Electrochemical biosensor employing PbS colloidal quantum dots/Au nanospheres-modified electrode for ultrasensitive glucose detection
    Zhao, Yunong
    Huang, Jing
    Huang, Qing
    Tao, Yanbing
    Gu, Ruiqin
    Li, Hua-Yao
    Liu, Huan
    NANO RESEARCH, 2023, 16 (03) : 4085 - 4092
  • [40] Hydrogen Peroxide Biosensor Based on Immobilization of Hemoglobin on Au@Ag Nanoparticles Modified Carbon Ionic Liquid Electrode
    Xia, Fa-Feng
    Xiao, Guo-Rong
    Ma, Chun-Yang
    Ma, Chun-Hua
    Chu, Dian-Qing
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2013, 60 (04) : 359 - 365