EFFECT OF THE THICKNESS OF PAN/Au MODIFIED ELECTRODE ON BIOSENSOR SENSITIVITY

被引:1
|
作者
Dong, Bo [1 ]
Lu, Xiaofeng [1 ]
Li, Zhenyu [1 ]
Zhang, Hongnan [1 ]
Wang, Zongxin [1 ]
Wang, Ce [1 ]
Liu, Zongwen [2 ]
机构
[1] Jilin Univ, Alan G MacDiarmid Inst, Changchun 130012, Peoples R China
[2] Univ Sydney, Sch Chem & Biomol Engn, Sydney, NSW 2006, Australia
关键词
Membrane thickness; polyacrylonitrile/gold nanofibers; electrocatalytic; hydrogen peroxide reduction; GOLD NANOPARTICLES;
D O I
10.1142/S179360471250035X
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A simple electrospinning method was used to control the thickness of polyacrylonitrile ( PAN)/Au modified electrode. The influence of membrane thickness to modified electrode sensitivity was discussed. In our experiment, a 20-min electrospinning time and a mass ratio of 3:1 PAN/HAuCl4 are the optimum parameters to generate the high performance PAN/Au membrane modified electrode for detecting H2O2 which has a sensitivity of 145.63 mA M-1 cm(-2)) and a wide linear range of 20 mu M-20 mM.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] An improved sensitivity nonenzymatic glucose biosensor based on a CUxO modified electrode
    Li, Cuiling
    Su, Yi
    Zhang, Senwang
    Lv, Xiangyu
    Xia, Hailong
    Wang, Yujiang
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (02): : 903 - 907
  • [2] Immobilization of glucose oxidase on gold nanoparticles modified Au electrode for the construction of biosensor
    Zhang, SX
    Wang, N
    Niu, YM
    Sun, CQ
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 109 (02) : 367 - 374
  • [3] A new biosensor for glucose based on Au colloid modified electrode and azure mediation
    Li, QF
    Yuan, R
    Yan, L
    Mo, CL
    Chai, YQ
    Huang, XQ
    Wang, XL
    Zhou, L
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (05) : 631 - 634
  • [4] Analysis of the effect of electrode thickness on QCM mass sensitivity
    Pan, Wei
    Huang, Xianhe
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [5] Glucose biosensor based on immobilization of glucose oxidase on silica nanoparticles modified Au electrode
    Sun, Yingying
    Zhao, Shuang
    Ran, Qunxiang
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY II, PTS 1 AND 2, 2012, 503-504 : 424 - +
  • [6] Development of electrochemical sulfite biosensor based on SOX/PBNPs/PPY modified Au electrode
    Rawal, Rachna
    Pundir, C. S.
    BIOCHEMICAL ENGINEERING JOURNAL, 2013, 71 : 30 - 37
  • [7] Enhancement effect of Ag-Au nanoparticles on glucose biosensor sensitivity
    Ren, XL
    Tang, FQ
    ACTA CHIMICA SINICA, 2002, 60 (03) : 393 - 397
  • [8] The Effect of Electrode Thickness on Mass Sensitivity of QCM Cannot Be Ignored
    Huang, Xianhe
    Chen, Qiao
    Pan, Wei
    Hu, Jianguo
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (04) : 1458 - 1461
  • [9] Lactic Acid Biosensor Based on Lactate Dehydrogenase Immobilized on Au Nanoparticle Modified Microwire Electrode
    Narayanan, J. Shankara
    Slaughter, Gymama
    IEEE SENSORS JOURNAL, 2020, 20 (08) : 4034 - 4040
  • [10] Biosensor based on bacterial cellulose-Au nanoparticles electrode modified with laccase for hydroquinone detection
    Li, Guohui
    Sun, Kaiyue
    Li, Dawei
    Lv, Pengfei
    Wang, Qingqing
    Huang, Fenglin
    Wei, Qufu
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2016, 509 : 408 - 414