Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip

被引:45
|
作者
Chopra, A. [1 ]
Grainger, A. J. [1 ,2 ,3 ]
Dube, B. [2 ,3 ]
Evans, R. [2 ,3 ]
Hodgson, R. [2 ,3 ]
Conroy, J. [4 ]
Macdonald, D. [5 ]
Robinson, Philip [1 ,2 ,3 ]
机构
[1] Chapel Allerton Hosp, Leeds Teaching Hosp, Dept Radiol, Leeds LS7 4SA, W Yorkshire, England
[2] Univ Leeds, Leeds, W Yorkshire, England
[3] Chapel Allerton Hosp, NHIR Leeds Musculoskeletal Biomed Res Ctr, Leeds, W Yorkshire, England
[4] Harrogate & Dist NHS Trust, Trauma & Orthopaed Dept, Harrogate, England
[5] Chapel Allerton Hosp, Leeds Teaching Hosp, Trauma & Orthopaed Dept, Leeds, W Yorkshire, England
关键词
Femoroacetabular impingement; MR Arthrography; 3T MRI; Acetabular labral tear; Articular cartilage; ACETABULAR LABRAL TEARS; OSTEOARTHRITIS OUTCOME SCORE; MR ARTHROGRAPHY; FEMOROACETABULAR IMPINGEMENT; CARTILAGE; LESIONS; REPLACEMENT; PREVALENCE; DISABILITY; TESTS;
D O I
10.1007/s00330-017-5069-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the diagnostic accuracy of conventional 3T MRI against 1.5T MR arthrography (MRA) in patients with clinical femoroacetabular impingement (FAI). Sixty-eight consecutive patients with clinical FAI underwent both 1.5T MRA and 3T MRI. Imaging was prospectively analysed by two musculoskeletal radiologists, blinded to patient outcomes and scored for internal derangement including labral and cartilage abnormality. Interobserver variation was assessed by kappa analysis. Thirty-nine patients subsequently underwent hip arthroscopy and surgical results and radiology findings were analysed. Both readers had higher sensitivities for detecting labral tears with 3T MRI compared to 1.5T MRA (not statistically significant p=0.07). For acetabular cartilage defect both readers had higher statistically significant sensitivities using 3T MRI compared to 1.5T MRA (p=0.02). Both readers had a slightly higher sensitivity for detecting delamination with 1.5T MRA compared to 3T MRI, but these differences were not statistically significant (p=0.66). Interobserver agreement was substantial to perfect agreement for all parameters except the identification of delamination (3T MRI showed moderate agreement and 1.5T MRA substantial agreement). Conventional 3T MRI may be at least equivalent to 1.5T MRA in detecting acetabular labrum and possibly superior to 1.5T MRA in detecting cartilage defects in patients with suspected FAI.
引用
收藏
页码:963 / 971
页数:9
相关论文
共 50 条
  • [41] Diagnostic Value of Breast Proton Magnetic Resonance Spectroscopy at 1.5T in Different Histopathological Types
    Baek, Hyeon-Man
    SCIENTIFIC WORLD JOURNAL, 2012,
  • [42] Functional magnetic resonance imaging at 3T in patients with intracranial tumors
    Tikkakoski, T
    ACTA RADIOLOGICA, 2005, 46 (06) : 555 - 555
  • [43] The effect of 1.5T cardiac magnetic resonance on human circulating leucocytes
    Critchley, William R.
    Reid, Anna
    Morris, Julie
    Naish, Josephine H.
    Stone, John P.
    Ball, Alexandra L.
    Major, Triin
    Clark, David
    Waldron, Nick
    Fortune, Christien
    Lagan, Jakub
    Lewis, Gavin A.
    Ainslie, Mark
    Schelbert, Erik B.
    Davis, Daniel M.
    Schmitt, Matthias
    Fildes, James E.
    Miller, Christopher A.
    EUROPEAN HEART JOURNAL, 2018, 39 (04) : 305 - 312
  • [44] The diagnostic test accuracy of magnetic resonance imaging, magnetic resonance arthrography and computer tomography in the detection of chondral lesions of the hip
    Smith T.O.
    Simpson M.
    Ejindu V.
    Hing C.B.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (3) : 335 - 344
  • [45] The effect of 1.5 T and 3 T magnetic resonance imaging on microleakage of amalgam restorations
    Erzurumlu, Zerrin Unal
    Guler, Cigdem
    Cender, Ebru Uslu
    Cakici, Elif B.
    Cankaya, Soner
    MICROSCOPY RESEARCH AND TECHNIQUE, 2019, 82 (11) : 1878 - 1883
  • [46] Evaluation of the diagnostic utility on 1.5T and 3.0T 1H magnetic resonance spectroscopy for temporal lobe epilepsy
    Biao Qu
    Hejuan Tan
    Min Xiao
    Dongbao Liu
    Shijin Wang
    Yiwen Zhang
    Runhan Chen
    Gaofeng Zheng
    Yonggui Yang
    Gen Yan
    Xiaobo Qu
    BMC Medical Imaging, 23
  • [47] Short Term Effects of Magnetic Resonance Imaging on Excitability of the Motor Cortex at 1.5T and 7T
    Schlamann, Marc
    Yoon, Min-Suk
    Maderwald, Stefan
    Pietrzyk, Thomas
    Bitz, Andreas K.
    Gerwig, Marcus
    Forsting, Michael
    Ladd, Susanne C.
    Ladd, Mark E.
    Kastrup, Oliver
    ACADEMIC RADIOLOGY, 2010, 17 (03) : 277 - 281
  • [48] The diagnostic accuracy of 1.5T magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries
    Wade, Ryckie G.
    Itte, Vinay
    Rankine, James J.
    Ridgway, John P.
    Bourke, Grainne
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (03) : 250 - 258
  • [49] Evaluation of the diagnostic utility on 1.5T and 3.0T 1H magnetic resonance spectroscopy for temporal lobe epilepsy
    Qu, Biao
    Tan, Hejuan
    Xiao, Min
    Liu, Dongbao
    Wang, Shijin
    Zhang, Yiwen
    Chen, Runhan
    Zheng, Gaofeng
    Yang, Yonggui
    Yan, Gen
    Qu, Xiaobo
    BMC MEDICAL IMAGING, 2023, 23 (01)
  • [50] Magnetic resonance imaging at 1.5T with immunospecific contrast agent in vitro and in vivo in a xenotransplant model
    Baio, G.
    Fabbi, M.
    de Totero, D.
    Ferrini, S.
    Cilli, M.
    Derchi, L. E.
    Neumaier, C. E.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2006, 19 (06) : 313 - 320