Comparative reliability and diagnostic performance of conventional 3T magnetic resonance imaging and 1.5T magnetic resonance arthrography for the evaluation of internal derangement of the hip

被引:45
|
作者
Chopra, A. [1 ]
Grainger, A. J. [1 ,2 ,3 ]
Dube, B. [2 ,3 ]
Evans, R. [2 ,3 ]
Hodgson, R. [2 ,3 ]
Conroy, J. [4 ]
Macdonald, D. [5 ]
Robinson, Philip [1 ,2 ,3 ]
机构
[1] Chapel Allerton Hosp, Leeds Teaching Hosp, Dept Radiol, Leeds LS7 4SA, W Yorkshire, England
[2] Univ Leeds, Leeds, W Yorkshire, England
[3] Chapel Allerton Hosp, NHIR Leeds Musculoskeletal Biomed Res Ctr, Leeds, W Yorkshire, England
[4] Harrogate & Dist NHS Trust, Trauma & Orthopaed Dept, Harrogate, England
[5] Chapel Allerton Hosp, Leeds Teaching Hosp, Trauma & Orthopaed Dept, Leeds, W Yorkshire, England
关键词
Femoroacetabular impingement; MR Arthrography; 3T MRI; Acetabular labral tear; Articular cartilage; ACETABULAR LABRAL TEARS; OSTEOARTHRITIS OUTCOME SCORE; MR ARTHROGRAPHY; FEMOROACETABULAR IMPINGEMENT; CARTILAGE; LESIONS; REPLACEMENT; PREVALENCE; DISABILITY; TESTS;
D O I
10.1007/s00330-017-5069-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To compare the diagnostic accuracy of conventional 3T MRI against 1.5T MR arthrography (MRA) in patients with clinical femoroacetabular impingement (FAI). Sixty-eight consecutive patients with clinical FAI underwent both 1.5T MRA and 3T MRI. Imaging was prospectively analysed by two musculoskeletal radiologists, blinded to patient outcomes and scored for internal derangement including labral and cartilage abnormality. Interobserver variation was assessed by kappa analysis. Thirty-nine patients subsequently underwent hip arthroscopy and surgical results and radiology findings were analysed. Both readers had higher sensitivities for detecting labral tears with 3T MRI compared to 1.5T MRA (not statistically significant p=0.07). For acetabular cartilage defect both readers had higher statistically significant sensitivities using 3T MRI compared to 1.5T MRA (p=0.02). Both readers had a slightly higher sensitivity for detecting delamination with 1.5T MRA compared to 3T MRI, but these differences were not statistically significant (p=0.66). Interobserver agreement was substantial to perfect agreement for all parameters except the identification of delamination (3T MRI showed moderate agreement and 1.5T MRA substantial agreement). Conventional 3T MRI may be at least equivalent to 1.5T MRA in detecting acetabular labrum and possibly superior to 1.5T MRA in detecting cartilage defects in patients with suspected FAI.
引用
收藏
页码:963 / 971
页数:9
相关论文
共 50 条
  • [21] Ferumoxytol-enhanced magnetic resonance imaging methodology and normal values at 1.5 and 3T
    Colin G. Stirrat
    Shirjel R. Alam
    Thomas J. MacGillivray
    Calum D. Gray
    Rachael Forsythe
    Marc R. Dweck
    John R. Payne
    Sanjay K. Prasad
    Mark C. Petrie
    Roy S. Gardner
    Saeed Mirsadraee
    Peter A. Henriksen
    David E. Newby
    Scott I. K. Semple
    Journal of Cardiovascular Magnetic Resonance, 18
  • [22] Assessment of the long head of the biceps tendon of the shoulder with 3T magnetic resonance arthrography and CT arthrography
    De Maeseneer, Michel
    Boulet, Cedric
    Pouliart, Nicole
    Kichouh, Mimoun
    Buls, Nico
    Verhelle, Filip
    De Mey, Johan
    Shahabpour, Maryam
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (05) : 934 - 939
  • [23] 3T magnetic resonance for evaluation of adult pulmonary tuberculosis
    Yan, Qinqin
    Yang, Shuyi
    Shen, Jie
    Lu, Shuihua
    Shan, Fei
    Shi, Yuxin
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2020, 93 : 287 - 294
  • [24] Dynamic magnetic resonance imaging of carbogen challenge on awake rabbit brain at 1.5T
    Chen, Po-Chou
    Shoa, Kuan-Hsiung
    Jao, Jo-Chi
    Hsiao, Chia-Chi
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (06) : 997 - 1009
  • [25] FUNCTIONAL MAGNETIC-RESONANCE-IMAGING AT 1.5T DURING SENSORIMOTOR AND COGNITIVE TASK
    SABBAH, P
    SIMOND, G
    LEVRIER, O
    HABIB, M
    TRABAUD, V
    MURAYAMA, N
    MAZOYER, BM
    BRIANT, JF
    RAYBAUD, C
    SALAMON, G
    EUROPEAN NEUROLOGY, 1995, 35 (03) : 131 - 136
  • [26] A Magnetic Resonance Imaging Surface Coil Transceiver Employing a Metasurface for 1.5T Applications
    Issa, Ismail
    Ford, Kenneth Lee
    Rao, Madhwesha
    Wild, Jim M.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (04) : 1085 - 1093
  • [27] A Sub-1dB NF Receiver for 1.5T Magnetic Resonance Imaging
    Yu, Chang
    Lv, Xiaojing
    Li, Yanhui
    Mo, Tingting
    2019 IEEE 13TH INTERNATIONAL CONFERENCE ON ASIC (ASICON), 2019,
  • [28] 3T Double Inversion Recovery Magnetic Resonance Imaging: diagnostic advantages in the evaluation of cortical development anomalies
    Granata, Francesca
    Morabito, Rosa
    Mormina, Enricomaria
    Alafaci, Concetta
    Marino, Silvia
    Lagana, Angela
    Vinci, Sergio Lucio
    Briguglio, Marilena
    Calamuneri, Alessandro
    Gaeta, Michele
    Salpietro, Vincenzo
    Longo, Marcello
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 906 - 914
  • [29] Imaging markers of bipolar disease: Evaluation of proton magnetic resonance spectroscopic imaging at 3T
    Port, JD
    Unal, SS
    Maroney-Smith, MJ
    Felmlee, JP
    Mrazek, DA
    BIOLOGICAL PSYCHIATRY, 2005, 57 (08) : 101S - 101S
  • [30] Advanced Magnetic Resonance Techniques: 3T
    Bhatti, Lubna
    Hoang, Jenny K.
    Dale, Brian M.
    Bashir, Mustafa R.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2015, 53 (03) : 441 - +