Study on the characteristics of X-ray spectra in imaging diagnosis using Monte Carlo simulations

被引:2
|
作者
Khanh Ai Tran [1 ]
Loan Thi Hong Truong [1 ]
Nhon Van Mai [1 ]
Phuong Nguyen Dang [2 ]
Dung Thi Thuy Vo [3 ]
机构
[1] VNU HCM Univ Sci, Fac Phys & Engn Phys, Ho Chi Minh City 700000, Vietnam
[2] Univ Freiburg, Inst Phys, D-79085 Freiburg, Germany
[3] Ho Chi Minh City Univ Pedag, Ho Chi Minh City 700000, Vietnam
关键词
X-ray spectrum; Simulation; MCNP5; code; DETECTOR; TUBES;
D O I
10.3938/jkps.69.1168
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
X-rays are widely used in diagnostic imaging such as radiography and computed tomography. An understanding of the X-ray spectrum is essential for estimating the dose absorbed by the patient and for improving image quality. In this research, X-ray emission spectra were investigated by using two different approaches: a Monte Carlo method using the MCNP5 code and a semi-empirical calculation with SpekCalc software. The results were compared with each other to validate the Monte Carlo simulation of the X-ray spectra, so that the simulation model can be applied to estimating the dose rate distribution in X-ray imaging. The obtained results show good agreement between the two approaches, but some divergence is still observed in the characteristic X-ray peaks. In addition, the influence of X-ray tube parameters such as the peak voltage, filter, anode angle and target material on of the beam quality was investigated.
引用
收藏
页码:1168 / 1174
页数:7
相关论文
共 50 条
  • [41] A bone composition model for Monte Carlo x-ray transport simulations
    Zhou, Hu
    Keall, Paul J.
    Graves, Edward E.
    MEDICAL PHYSICS, 2009, 36 (03) : 1008 - 1018
  • [42] Monte Carlo simulator for x-ray spectra analysis of GaAs detectors
    Cola, A
    Reggiani, L
    Vasanelli, L
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS, 1999, 3768 : 392 - 399
  • [43] Simulations of X-ray spectra, half value layer, and mean energy from mammography using EGSnrc Monte Carlo and SpekPy
    Huy, B. Ngoc
    Van Dung, P.
    RADIOGRAPHY, 2023, 29 (01) : 28 - 37
  • [44] Validation of X-Ray Spectra in Screening Mammography Simulated with Monte Carlo
    Talbi, Mohammed
    El Mansouri, M'hamed
    Oustous, Aziz
    Nhila, Oussama
    Sebihi, Rajaa
    Khalis, Mohammed
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (SUPPL 1) : S30 - S35
  • [45] Validation of X-Ray Spectra in Screening Mammography Simulated with Monte Carlo
    Mohammed Talbi
    M’hamed El Mansouri
    Aziz Oustous
    Oussama Nhila
    Rajaa Sebihi
    Mohammed Khalis
    Moscow University Physics Bulletin, 2021, 76 : S30 - S35
  • [46] MANTIS: combined x-ray, electron and optical Monte Carlo simulations of indirect radiation imaging systems
    Badano, A
    Sempau, J
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (06): : 1545 - 1561
  • [47] Multiscale Monte Carlo simulations for dosimetry in x-ray breast imaging: Part I - Macroscopic scales
    Massera, Rodrigo T.
    Tomal, Alessandra
    Thomson, Rowan M.
    MEDICAL PHYSICS, 2024, 51 (02) : 1105 - 1116
  • [48] Monte Carlo validation of optimal material discrimination using spectral x-ray imaging
    Nik, S. J.
    Thing, R. S.
    Watts, R.
    Dale, T.
    Currie, B.
    Meyer, J.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [49] X-ray Coherent Scatter Imaging for Surgical Margin Detection: A Monte Carlo Study
    Lakshmanan, Manu N.
    Kapadia, Anuj J.
    Harrawood, Brian P.
    Brady, David
    Samei, Ehsan
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [50] X-ray and optical Monte Carlo study of thick, segmented scintillators for MV imaging
    Monajemi, T.
    Fallone, B.
    Rathee, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2220 - 2221