Study on the characteristics of X-ray spectra in imaging diagnosis using Monte Carlo simulations

被引:2
|
作者
Khanh Ai Tran [1 ]
Loan Thi Hong Truong [1 ]
Nhon Van Mai [1 ]
Phuong Nguyen Dang [2 ]
Dung Thi Thuy Vo [3 ]
机构
[1] VNU HCM Univ Sci, Fac Phys & Engn Phys, Ho Chi Minh City 700000, Vietnam
[2] Univ Freiburg, Inst Phys, D-79085 Freiburg, Germany
[3] Ho Chi Minh City Univ Pedag, Ho Chi Minh City 700000, Vietnam
关键词
X-ray spectrum; Simulation; MCNP5; code; DETECTOR; TUBES;
D O I
10.3938/jkps.69.1168
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
X-rays are widely used in diagnostic imaging such as radiography and computed tomography. An understanding of the X-ray spectrum is essential for estimating the dose absorbed by the patient and for improving image quality. In this research, X-ray emission spectra were investigated by using two different approaches: a Monte Carlo method using the MCNP5 code and a semi-empirical calculation with SpekCalc software. The results were compared with each other to validate the Monte Carlo simulation of the X-ray spectra, so that the simulation model can be applied to estimating the dose rate distribution in X-ray imaging. The obtained results show good agreement between the two approaches, but some divergence is still observed in the characteristic X-ray peaks. In addition, the influence of X-ray tube parameters such as the peak voltage, filter, anode angle and target material on of the beam quality was investigated.
引用
收藏
页码:1168 / 1174
页数:7
相关论文
共 50 条
  • [31] Monte Carlo modeling of field angle-dependent spectra for X-ray imaging systems
    Gindele, Edward B.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [32] Off-axis x-ray spectra: A comparison of Monte Carlo simulated and computed x-ray spectra with measured spectra
    Bhat, M
    Pattison, J
    Bibbo, G
    Caon, M
    MEDICAL PHYSICS, 1999, 26 (02) : 303 - 309
  • [33] Sensitivity study of proton radiography and comparison with kV and MV x-ray imaging using GEANT4 Monte Carlo simulations
    Depauw, Nicolas
    Seco, Joao
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08): : 2407 - 2421
  • [34] Monte-Carlo Simulations of a Coded-Aperture X-ray Scatter Imaging System for Molecular Imaging
    Kapadia, Anuj J.
    Lakshmanan, Manu N.
    Krishnamurthy, Kalyani
    Sahbaee, Pooyan
    Chawla, Amarpreet
    Wolter, Scott
    Maccabe, Ken
    Brady, David
    Samei, Ehsan
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [35] X-ray dosimetry: comparing Monte Carlo simulations and experimental data
    Stichelbaut, F
    Bol, JL
    Lundhal, B
    Martin, F
    Rose, G
    Schlecht, J
    Smith, R
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (1-2) : 345 - 349
  • [36] Nonspecular X-ray scattering from multilayers: Monte Carlo simulations
    Technical Univ of Lublin, Lublin, Poland
    Electron Technology (Warsaw), 1998, 31 (3-4): : 393 - 398
  • [37] Monte Carlo simulations of dual energy X-ray inspection systems
    Department of Engineering Physics, Tsinghua University, Beijing 100084, China
    Qinghua Daxue Xuebao, 2006, 6 (813-816):
  • [38] Monte Carlo simulations of X-ray continuum of SS433
    Krivosheyev, Yu. M.
    Bisnovatyi-Kogan, G. S.
    Cherepashchuk, A. M.
    Postnov, K. A.
    X-RAY ASTRONOMY-2009: PRESENT STATUS, MULTI-WAVELENGTH APPROACH AND FUTURE PERSPECTIVES, PROCEEDINGS, 2010, 1248 : 171 - +
  • [39] Monte Carlo simulations of x-ray induced recombination in amorphous selenium
    Lachaine, M
    Fallone, BG
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2000, 33 (11) : 1417 - 1423
  • [40] Monte Carlo polarimetric simulations of a hard X-ray energy telescope
    da Silva, RMC
    Caroli, E
    Stephen, JB
    Siffert, P
    X-RAY AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY XII, 2002, 4497 : 70 - 78