Ferromagnetic resonance detection for magnetic microbead sensors

被引:6
|
作者
Ghionea, Simon [1 ]
Dhagat, Pallavi [1 ]
Jander, Albrecht [1 ]
机构
[1] Oregon State Univ, Corvallis, OR 97330 USA
基金
美国国家科学基金会;
关键词
biomedical transducers; ferroresonance; magnetic; resonance; microsensors;
D O I
10.1109/JSEN.2008.923904
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a novel detection scheme for magnetic beads used to label target molecules in immunoassay based sensors. The beads are detected inductively using a microwave circuit consisting of a slotline and coplanar waveguide (CPW) fabricated in a single metal layer. The waveguides are terminated at a short-circuited junction that serves as the active sensor area. When the slotline is excited by an input radio frequency (RF) signal, ac magnetic fields are generated at the junction. These fields are orthogonal to the propagation mode allowed in CPWs. As a result, the signal from the slotline does not nominally couple into the CPW. In the presence of a bead immobilized at the junction, fields from the slotline are distorted and the signal is coupled to the output at the CPW. The output signal is further enhanced by exciting ferromagnetic resonance in the bead. Simulation results indicate a single bead to be detectable with a sensitivity of 1-10 mu V/V depending on its location in the active sensor area and the waveguide geometry. The distinctive advantages of this detection technique are ease of implementation, requiring simple and inexpensive fabrication processes; and suitability for integration in lab-on-a-chip systems.
引用
收藏
页码:896 / 902
页数:7
相关论文
共 50 条
  • [41] Magnetic Sensors Based on Amorphous Ferromagnetic Materials: A Review
    Moron, Carlos
    Cabrera, Carolina
    Moron, Alberto
    Garcia, Alfonso
    Gonzalez, Mercedes
    SENSORS, 2015, 15 (11) : 28340 - 28366
  • [42] LINEARITY OF FERROMAGNETIC CORE SOLENOIDS USED AS MAGNETIC SENSORS
    UEDA, H
    WATANABE, T
    JOURNAL OF GEOMAGNETISM AND GEOELECTRICITY, 1980, 32 (05): : 285 - 295
  • [43] Sensors for nondestructive magnetic anisotropy monitoring on ferromagnetic sheets
    Korzunin, GS
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 1999, 35 (05) : 351 - 357
  • [44] Detection of a single magnetic microbead using a miniaturized silicon Hall sensor
    Besse, PA
    Boero, G
    Demierre, M
    Pott, V
    Popovic, R
    APPLIED PHYSICS LETTERS, 2002, 80 (22) : 4199 - 4201
  • [45] NUCLEAR MAGNETIC-RESONANCE IN FERROMAGNETIC TERBIUM
    COWAN, DL
    CHA, CL
    SOLID STATE COMMUNICATIONS, 1979, 32 (12) : 1275 - 1278
  • [46] Ferromagnetic resonance in granular soft magnetic films
    Corte-Real, MM
    Du, J
    Unruh, KM
    Xiao, JQ
    IEEE TRANSACTIONS ON MAGNETICS, 2003, 39 (05) : 3091 - 3093
  • [47] Magnetomechanical coupling and ferromagnetic resonance in magnetic nanoparticles
    Keshtgar, Hedyeh
    Streib, Simon
    Kamra, Akashdeep
    Blanter, Yaroslav M.
    Bauer, Gerrit E. W.
    PHYSICAL REVIEW B, 2017, 95 (13)
  • [48] FERROMAGNETIC RESONANCE LINEWIDTH IN THIN MAGNETIC FILMS
    SALANSKY, NM
    KHRUSTAL.BP
    MELNIK, AS
    SALANSKA.LA
    SINEGUBO.ZI
    THIN SOLID FILMS, 1969, 4 (02) : 105 - &
  • [49] FERROMAGNETIC-RESONANCE IN MAGNETIC MULTILAYER STRUCTURES
    MCKNIGHT, SW
    VITTORIA, C
    PHYSICAL REVIEW B, 1987, 36 (16): : 8574 - 8581
  • [50] FERROMAGNETIC AND TRANSMISSION RESONANCE IN MAGNETIC METAL SUPERLATTICES